Comparison of the Accuracy and Precision of a Zero Heat Flux Thermometer (SpotOn) Versus Pulmonary Artery Temperature.

An observational study of Temperature Monitoring and Cardiac Surgical Procedures, run by Copenhagen University Hospital, Rigshospitalet at 1 site in Denmark.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In this study, we aim to compare the core temperature measured with two noninvasive ZHF thermometers and a urinary bladder thermometer against a gold standard blood temperature measured in the pulmonary artery in patients undergoing on-pump cardiac surgery. Read more about this study

Who is it for?
Any age
What is being tested?
Zero Heat Flux Thermometer
Type of treatment
Medical device
How many people
100 participants
Where
1 siteDenmark
Study dates
1 Sep 2018to 1 Jul 2022
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Child, Adult, Older adult

Study population: Adult patients of both genders scheduled for cardiac surgery with CPB for either coronary artery bypass grafting (CABG), aortic valve replacement (AVR), mitral valve replacement (MVR) or CABG + AVR

Who may be able to join

  • Adult patients of both genders scheduled for cardiac surgery with CPB for either coronary artery bypass grafting (CABG), aortic valve replacement (AVR), mitral valve replacement (MVR) or CABG + AVR

Who cannot join

  • Exclusion criteria if any interruption of skin on the forehead, planned direct heat application to the forehead, or previous cerebral stroke, that might affect the accuracy of the ZHF device

Trial locations and contacts

1 site in 1 country.

Denmark1 site
  • Rigshospitalet, Copenhagen University Denmark

    Copenhagen, 2100

Other trials in Denmark

About this study

Official title: Comparison of the Accuracy and Precision of a Zero Heat Flux Thermometer (SpotOnTM) Versus Pulmonary Artery Temperature Measurement in Patients Undergoing On-pump Heart Surgery: a Prospective, Multicentre, Observational Study.

In this study, we aim to compare the core temperature measured with two noninvasive ZHF thermometers and a urinary bladder thermometer against a gold standard blood temperature measured in the pulmonary artery in patients undergoing on-pump cardiac surgery. Additionally we intend to compare the reproducibility of the ZHF measurements by using two devices simultaneously in each patient.

Read the detailed description

Anesthesia will be induced with fentanyl, propofol and rocuronium and maintained with sevoflurane and fentanyl or sevoflurane and remifentanil infusion. Hypotension after induction of anesthesia will be treated primarily with phenylephrine or ephedrine and secondarily with norepinephrine infusion.

After induction of anesthesia a PAC (Edwards Lifescience, Thermodilution Paceport Catheter 931F75, 7.5F (2.5 mm) 110 cm) will be inserted in the pulmonary artery and connected to a Vigilance 2-monitor. Core temperature at the tip of the PAC will be measured every minute and displayed on the monitor. Two SpotOn™ ZHF temperature monitoring probes (3M, Model 370 Temperature Monitoring System, St. Paul, MN) will be fixed on the skin of the left and right side of the forehead above the eyebrow before induction of anesthesia. These devices also measured core temperature every minute and displayed the values on two display screens. In addition a temperature-sensing indwelling urinary catheter (CovidienTM, Mon-a-ThermTM, Foly Catheter with temperature sensor 400TM) will be placed after induction of anesthesia to allow continuous drainage of urine and continuous measurement of body temperature.

Core temperatures measured by PAC, ZHF-thermometer and bladder thermometer will be recorded with an interval of 1 minute.

In all patients the core temperature are allowed to drop until going on CPB. There will be no no external warming or infusion warming before CPB. At initiation of CPB measurements will stop because during CPB core temperatures measured with PAC does not produce an accurate estimate of core temperature.

Being tested
Zero Heat Flux Thermometer
Keywords
Thermometers, Thoracic surgery, Perioperative monitoring, Temperature monitoring, Anesthesia, Body temperature, Cardiac surgical procedures

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Zero Heat Flux ThermometerDevice

    Also called Pulmonary Artery Temperature

    Comparison of the accuracy and precision of a Zero Heat Flux Thermometer (SpotOn) Versus Pulmonary Artery Temperature Measurement

Study groups in NCT05737147
Study groupRoleWhat they receive
100 adult patients of both genders scheduled for cardiac surgery100 adult patients of both genders scheduled for cardiac surgery with CPB for either coronary artery bypass grafting (CABG), aortic valve replacement (AVR), mitral valve replacement (MVR) or CABG + AVR.
Receives: Device: Zero Heat Flux Thermometer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. ZHF temperature right side versus PAC temperature.

    ZHF temperature measured on the right side of the forehead versus PAC temperature.

    Measured: Perioperatively

  2. ZHF temperature left side versus PAC temperature.

    ZHF temperature measured on the left side of the forehead versus PAC temperature.

    Measured: Perioperatively

  3. ZHF temperature right side versus ZHF temperature left side

    ZHF temperature measured on the right side of the forehead versus ZHF temperature measured on the left side of the forehead

    Measured: Perioperatively

  4. Bladder temperature versus PAC temperature

    Bladder temperature versus PAC temperature

    Measured: Perioperatively

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted21 Feb 2023
  2. Study start1 Sep 2018
  3. Primary completion1 Oct 2020
  4. Study completion1 Jul 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
100 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05737147
Sponsor's protocol ID
17025426
Status last verified
Mar 2023
First submitted
12 Feb 2023
Last updated
17 Mar 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

An observational study of Temperature Monitoring and Cardiac Surgical Procedures, run by Copenhagen University Hospital, Rigshospitalet at 1 site in Denmark.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

ZHF temperature right side versus PAC temperature. (time frame: Perioperatively). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Mar 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in