Deviation Between Virtual and Actual Computer Guided Immediate Implants Using the New Safe Angle Position Concept

A study testing computer guided immediate implant placement in people with Immediate Implants, run by Ahmed Abo El Futtouh at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this case series study is to assess the degree of angular deviation between virtual and actual computer guided immediate implant placement in anterior maxilla using the new safe angle position concept and the resultant effects on soft and hard tissues. Read more about this study

Who is it for?
Ages 20 to 50 years
Conditions the study is for
Immediate Implants
What is being tested?
computer guided immediate implant placement
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
26 participants
Where
1 siteEgypt
Study dates
1 Apr 2023to 1 Jul 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 50 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • Adults ≥ 20 years to 50 years of both genders and in good general health.
  • Maxillary anterior tooth that cannot be retained due to non-periodontitis, including fracture, endodontic failure, and root resorption, bounded by natural teeth.
  • Intact buccal bone plate (via CBCT).
  • The extraction socket has at least 3-5 mm apical bone.

Who cannot join

  • 1. Smokers 2. Pregnant and lactating females: Pregnancy as this will limit recording the outcome data eg: CBCT.
  • 3. Medically compromised patients, as uncontrolled diabetic patients, patients taking bisphosphonates injection for treatment of osteoporosis, patients with active cardiac diseases, patients undergoing radiotherapy or chemotherapy, or any other medical and general contraindications for the surgical procedure (i.e. ASA score ≥III) (31) 4. Patients with active infection related at the site of implant/bone graft placement.
  • 5. Patients with untreated active periodontal diseases. 6. Patients with parafunctional habits. 7. Refuse to participate in this study.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • International Dental Contining Education Centre (IDCE)

    Cairo

Other trials in Egypt

About this study

Official title: The Deviation Between the Planned and Actual Positions of Immediate Implants Placed in the Anterior Maxilla Using the Virtual Safe Angle Concept and a Novel Computer-guided Drilling Protocol. A Prospective Clinical Trial

The goal of this case series study is to assess the degree of angular deviation between virtual and actual computer guided immediate implant placement in anterior maxilla using the new safe angle position concept and the resultant effects on soft and hard tissues. Patients with non-restorable anterior maxillary teeth will be managed with flapless computer guided immediate implant placement fabricated using safe angle concept.

Read the detailed description

Various research investigated the distance deviations at the entrance and apical points of angular deviation to investigate the clinical accuracy of implant placement using these surgical procedures. Additionally, the 3D variations between the intended and postoperative implant placements are evaluated in the mesio-distal, bucco-lingual, and vertical directions. The vertical orientations are all constrained by bone volume; nevertheless, the greatest contributors to 3D deviations in implant location are bucco-lingual and mesio-distal deviations. Few research have been done to examine the variables affecting implant placement accuracy using free-hand surgical procedures. Due to drilling errors caused by drills travelling along the paths of least resistance during IIP and socket morphology, implants frequently end up in the facial region even when surgical guidelines are present. This is more typical for anterior maxilla implants. The incisal long axis, which is perpendicular to the palate or the occlusal plane, and the root's long axis connect at an angle. The incisal plane line will be at the cingulum position or slightly palatal to it when this relation is shifted more palatally, and this position is known as the safe angle position. According to the amount of palatal bone present, the occlusion with the opposing dentition, and the type of restoration, the more palatal relocation to the cingulum is carried out. Immediate implants in the safe angle position are more likely to predictably achieve good implant location (less angular deviation), improved aesthetics and emergence profile, and less stresses on the implant.

Being tested
computer guided immediate implant placement
Keywords
Immediate implant placement, computer guided, safe angle position, Angular deviation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • computer guided immediate implant placementProcedure or surgery

    Atraumatic extraction followed by immediate implant placement using safe angle position computer guided surgical stents, followed by customized healing abutments. after 3 months, Impressions for final prosthesis will be done

Study groups in NCT05750004
Study groupRoleWhat they receive
Computer guided immediate implant placementExperimentalAtraumatic extraction followed by immediate implant placement using safe angle position computer guided surgical stents.
Receives: Procedure: computer guided immediate implant placement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Angular deviations

    Angular discrepancy (measured in degrees) be-tween the planned and actual implant position respective to the center of the implant body. It is primarily ascribed to a variation in point of implant entry

    Measured: 9 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Mar 2023
  2. Study start1 Apr 2023
  3. Primary completion1 Jun 2024
  4. Study completion1 Jul 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
A prospective clinical trial
Masking
None (open label)
Enrolment
26 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05750004
Sponsor's protocol ID
OSA3231001
Status last verified
Jan 2026
First submitted
19 Feb 2023
Last updated
29 Jan 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Fettouh AIA, Fouad A, Keraa K, Nasser R, Adel N, Kastour I, El-Zayat I. The deviation between the planned and actual positions of immediate implants placed in the anterior maxilla using the virtual safe angle concept and a novel computer-guided drilling protocol: A prospective clinical trial. BMC Oral Health. 2026 May 5;26(1):815. doi: 10.1186/s12903-026-08408-1.

    PubMed 42087162

Questions about this trial

What is this clinical trial studying?

A study testing computer guided immediate implant placement in people with Immediate Implants, run by Ahmed Abo El Futtouh at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Angular deviations (time frame: 9 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05750004, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Jan 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in