Arrhythmias, CardiacNCT05756309

Validation of ECG Waveform and Arrhythmia Diagnosis Concordance for Pediatric Patients Using ECG Monitoring Patch

A study testing Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same time in people with Arrhythmias, Cardiac, run by Mezoo Co., Ltd. at 1 site in South Korea.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This study will verify the 1-channel patch-type ECG's arrhythmia diagnostic concordance rate and electrocardiogram measurement performance in pediatric patients by collecting ECG signals from patch-type ECG and Holter device simultaneously for data analysis. Read more about this study

Who is it for?
Ages 29 days to 19 years
Conditions the study is for
Arrhythmias, Cardiac
What is being tested?
Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same time
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
105 participants
Where
1 siteSouth Korea
Study dates
16 Jan 2023to 30 Dec 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 29 days to 19 years
  • All sexes
  • No healthy volunteers
  • Child, Adult

Who may be able to join

  • More than 29 days old and less than 19 years old
  • Patients who are need regular Holter electrocardiography among outpatients or hospitalized patients at the Pediatrics, Samsung Medical Center
  • Those who gave written consent to this clinical study or obtained the written consent of the legal representative

Who cannot join

  • Patients who cannot give consent through the patient ownself or legal representative
  • If the researcher judges that participation in this study is inappropriate for other reasons

Trial locations and contacts

1 site in 1 country.

South Korea1 site, 1 recruiting
  • Samsung Medical Center

    Seoul

    J Huh

    Recruiting

Other trials in South Korea

About this study

Official title: Validation of Electrocardiogram Waveform, Heart Rate Accuracy and Arrhythmia Diagnosis Concordance for Pediatric Patients Using Single-channel ECG Monitoring Patch and Holter Monitoring

This study will verify the 1-channel patch-type ECG's arrhythmia diagnostic concordance rate and electrocardiogram measurement performance in pediatric patients by collecting ECG signals from patch-type ECG and Holter device simultaneously for data analysis.

Read the detailed description

[How to conduct research] This study targeted more than 29 days old and less than 19 years old. Written consent is obtained from those who need a Holter examination among outpatients or inpatients at the Pediatrics of Samsung Medical Center. The medical staff attaches the Holter device to the subject and the patch-type electrocardiograph in the Holter examination room. Holter device and patch-type electrocardiograph are returned to the Holter examination room after measuring the electrocardiogram for 24 hours. ECG signals from patch-type electrocardiographs and commercial Holter device and arrhythmia detection information are compared and analyzed.

[Number of Subjects] The number of this study is 105. Written consent is obtained from those who need a Holter examination among outpatients or inpatients at the Pediatrics.

[Data analysis plan] In this study, the personal identification information of the subjects will be coded non-identifying and the collected electrocardiogram data will be stored in the cloud with restricted access from outsiders. Coded, non-identified research data is stored and managed in the cloud in compliance with privacy standards and information security standards. ECG data transmitted through the mobile application is stored in the cloud. Confidentiality and security of data are guaranteed, and data collected from patch-type electrocardiograph is used only for research. The electrocardiogram data acquired in this study are obtained in TXT or MAT format and used for data analysis.

The efficacy evaluation items are as follows.

  1. Comparison of ECG signal concordance
  2. Comparison of the parameters below for a noise-free section of about 1 minute, not the entire section
  • P-wave, QRS-complex, T-wave: Sensitivity, Positive Predictive Value, Amplitude difference, Correlation to the entire signal
  • P, QRS, T (On/Off time): Time difference
  • PR, QRS, QT (Duration/Interval): Time difference
  1. Comparison of arrhythmia diagnosis concordance rates between 24-hour patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories (total of 19 including ventricular ectopic beat)

The evaluation method and interpretation method are as follows.

  1. In the case of categorical variables, the sensitivity and positive predictive value are evaluated, and in the case of continuous variables, the concordance between the measured values measured by the patch-type electrocardiograph and the Holter device is evaluated using the Bland-Altman plot.
  2. Amplitude difference of P-wave, QRS-complex and T-wave \& Correlation to the entire signal
  • Peaks of P-wave, QRS-complex (R-wave peaks) and peaks of T-wave are manually annotated in the holter device and patch-type ECG independently to assess amplitude difference and correlation to the entire ECG signal.
  1. Time difference of P, QRS, T (On/Off time) \& PR, QRS, QT (Duration/Interval)
  • Exact timing of fiducial markers such as onset of P-wave and QRS-complex, and offset of P-wave, QRS-complex, T-wave and clinically useful intervals and durations (PR-interval, RR interval, QT interval, P-wave duration, QRS-duration) are manually annotated in the holter device and patch-type ECG independently to quantify the accuracy of delineating these characteristic points in the patch sensor.
  1. Root Mean Square of Heart Rate
  • Calculate and analyze the square root after averaging the squares of each heart rate value in the analysis section from the electrocardiogram obtained simultaneously from the Holter device and the patch-type electrocardiograph
Being tested
Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same time
Keywords
ECG monitoring patch, Validation of Electrocardiogram waveform, Validation of heart rate accuracy, Validation of arrhythmia diagnosis concordance, Patients with cardiac arrhythmia, Holter, Wearable patch-type electrocardiograph
Medical subject headings
Arrhythmias, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same timeDevice

    The patient is measured electrocardiogram simultaneously through a holter device and patch-type electrocardiograph

Study groups in NCT05756309
Study groupRoleWhat they receive
Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same timeExperimentalThe patient is measured electrocardiogram simultaneously through a holter device and patch-type electrocardiograph
Receives: Device: Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same time

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Rate of arrhythmia diagnosis between patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories

    Rate of arrhythmia diagnosis between 24-hour patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories(total of 19 including ventricular ectopic beat)

    Measured: Within 3 months after electrocardiogram procedure

  2. Rate of ECG signal concordance between patch-type electrocardiograph and holter device

    Calculate the concordance (%) of the ECG signal by comparing and analyzing total QRS complex, total ventricular ectopic beats, total atrial ectopic beats, minimum heart rate(bpm), maximum heart rate(bpm), average heart rate(bpm) and maximum RR interval(ms)

    Measured: Within 3 months after electrocardiogram procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Mar 2023
  2. Study start16 Jan 2023
  3. Primary completion30 Dec 2024 (estimated)
  4. Study completion30 Dec 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
105 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05756309
Sponsor's protocol ID
CDV-2022-02
Status last verified
Aug 2024
First submitted
13 Feb 2023
Last updated
9 Aug 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Rajbhandary PL, Nallathambi G, Selvaraj N, Tran T, Colliou O. ECG Signal Quality Assessments of a Small Bipolar Single-Lead Wearable Patch Sensor. Cardiovasc Eng Technol. 2022 Oct;13(5):783-796. doi: 10.1007/s13239-022-00617-3. Epub 2022 Mar 15.

    PubMed 35292914
  • Kancharla K, Estes NAM. Mobile cardiac monitoring during the COVID-19 pandemic: Necessity is the mother of invention. J Cardiovasc Electrophysiol. 2020 Nov;31(11):2812-2813. doi: 10.1111/jce.14726. Epub 2020 Sep 3. No abstract available.

    PubMed 32852854
  • Fung E, Jarvelin MR, Doshi RN, Shinbane JS, Carlson SK, Grazette LP, Chang PM, Sangha RS, Huikuri HV, Peters NS. Electrocardiographic patch devices and contemporary wireless cardiac monitoring. Front Physiol. 2015 May 27;6:149. doi: 10.3389/fphys.2015.00149. eCollection 2015.

    PubMed 26074823
  • Kennedy HL. The evolution of ambulatory ECG monitoring. Prog Cardiovasc Dis. 2013 Sep-Oct;56(2):127-32. doi: 10.1016/j.pcad.2013.08.005. Epub 2013 Sep 11.

    PubMed 24215744
  • Garson A Jr. Arrhythmias in pediatric patients. Med Clin North Am. 1984 Sep;68(5):1171-210. doi: 10.1016/s0025-7125(16)31091-4.

    PubMed 6492933
  • Solomon MD, Yang J, Sung SH, Livingston ML, Sarlas G, Lenane JC, Go AS. Incidence and timing of potentially high-risk arrhythmias detected through long term continuous ambulatory electrocardiographic monitoring. BMC Cardiovasc Disord. 2016 Feb 17;16:35. doi: 10.1186/s12872-016-0210-x.

    PubMed 26883019
  • Yenikomshian M, Jarvis J, Patton C, Yee C, Mortimer R, Birnbaum H, Topash M. Cardiac arrhythmia detection outcomes among patients monitored with the Zio patch system: a systematic literature review. Curr Med Res Opin. 2019 Oct;35(10):1659-1670. doi: 10.1080/03007995.2019.1610370. Epub 2019 May 28.

    PubMed 31045463

Questions about this trial

What is this clinical trial studying?

A study testing Electrocardiogram measurements by holter device and patch-type electrocardiographic at the same time in people with Arrhythmias, Cardiac, run by Mezoo Co., Ltd. at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Aug 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Sanghee Lee (82-33-761-2006 ext. 412, shlee@me-zoo.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Rate of arrhythmia diagnosis between patch-type electrocardiograph and commercial Holter device measurement data by arrhythmia categories (time frame: Within 3 months after electrocardiogram procedure). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05756309, which also lists 7 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Aug 2024; AzTrials last refreshed its copy on 8 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in