SyncopeBlotSpotNCT05782712
Rapid Measurement of Adenosine in Syncope Patients
An observational study of Syncope, run by Istituto Auxologico Italiano at 1 site in Italy.
Trial summary
Until now, a barrier to the widespread evaluation of adenosine in clinical practice has been the difficulty of obtaining rapid reliable measures. A rapid method has recently been developed which consists of measuring adenosine concentration in whole blood instead of plasma by means of Mass Spectrometry (LC-MS/MS). Read more about this study
- Who is it for?
- Ages 16 years and older
- Conditions the study is for
- Syncope
- What is being tested?
- adenosine dosage
- How many people
- 235 participants
- Where
- 1 siteItaly
- Study dates
- 4 Oct 2021to 31 May 2022
- How long will I take part?
- 1 Day
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 16 years and older
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Study population: Syncope group: patients referred to the Syncope Unit of Auxologico with a diagnosis of possible or certain reflex syncope (class I diagnostic criteria of ESC guidelines) after exclusion of competing diagnoses. No syncope group: 1) Patients without a history of syncope, referred to Auxologico for other reasons; these patients have absence of severe structural heart disease and other comorbidities. 2) Healthy volunteers selected among personnel of Auxologico. The selection of these patients will be made matching them to syncope cases by age and sex.
Who may be able to join
- patients referred to the Syncope Unit of Auxologico with a diagnosis of possible or certain reflex syncope (class I diagnostic criteria of ESC guidelines)
Who cannot join
None listed.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Rapid Measurement of Adenosine Concentration in Patients With Syncope
Until now, a barrier to the widespread evaluation of adenosine in clinical practice has been the difficulty of obtaining rapid reliable measures. A rapid method has recently been developed which consists of measuring adenosine concentration in whole blood instead of plasma by means of Mass Spectrometry (LC-MS/MS). In this study adenosine plasma levels were assessed in a larger unselected cohort of patients affected by non-cardiac syncope and compared the results with healthy controls.
Read the detailed description
Rationale and aim Until now, a barrier to the widespread evaluation of adenosine in clinical practice has been the difficulty of obtaining rapid reliable measures. Indeed, owing to its short half-life in the blood, adenosine is not easy to sample and measure. At the time of venepuncture, a stop solution - not commercially available - must be utilized in order to inhibit the degradation of adenosine in body fluid. After plasma deproteinization, adenosine concentration is evaluated by means of high-performance liquid chromatography.
A rapid method has recently been developed which consists of measuring adenosine concentration in whole blood instead of plasma by means of Mass Spectrometry (LC-MS/MS). In brief, whole blood is collected after finger puncture and a drop is deposited on a blot paper (Whatman). After the extraction of adenosine by means of a mixture consisting of methanol and internal standard, its concentration is measured by LC-MS/MS. This method is rapid, well accepted by the patient, not expensive, and easily replicable. Comparison between the two above-mentioned methods in 20 healthy subjects and in patients with vasovagal syncope has shown an acceptable correlation, with a r=0.65 and p<0.01. The mean adenosine concentration was significantly higher in vasovagal syncope patients than in controls (3.1 µM versus 0.60 µM, p<0.001). However, the above results need to be replicated in a larger sample of patients and controls before the blot paper method of measurement of adenosine can replace the standard method.
In this study denosine plasma levels was assessed in a larger unselected cohort of patients affected by non-cardiac syncope and compared the results with healthy controls.
Study design The rapid method of adenosine dosage in whole blood was assessed in patients with syncope and in controls. The study was performed in patients referred to Istituto Auxologico Italiano. The blood sample was be shipped to the Laboratory of Biochemistry, Timone Hospital 264 Rue Saint-Pierre, 13385 Marseille, France for analysis Syncope group: patients referred to the Syncope Unit of Auxologico with a diagnosis of possible or certain reflex syncope (class I diagnostic criteria of ESC guidelines) after exclusion of competing diagnoses.
There syncope patients are subdivided in 3 predefined subgroups:
- Subgroup A) Patients with no prodromes or very short prodromes (5 sec), normal heart and normal ECG
- Subgroup B) Patients with typical vasovagal features (orthostatic or emotional triggers, long prodromes with signs and symptoms of autonomic activation, i.e, nausea, sweating, dizziness, pallor)
- Subgroup C) Patients who do not belong to none of the above subgroups.
No syncope group: 1) Patients without a history of syncope, referred to Auxologico for other reasons; these patients have absence of severe structural heart disease and other comorbidities. 2) Healthy volunteers selected among personnel of Auxologico. The selection of these patients will be made matching them to syncope cases by age and sex.
Blood samples collection Whole blood is collected using finger puncture followed by deposit a drop of blood (20 μL) using finnpipette, on a blotting paper (Whatman 903 protein saver cards™) and dried over night at room temperature to obtain dried blood spot (DBS).
Blood samples extraction Six millimeters of dried blood spot (DBS) are cut out followed by extraction with mixture consisting of methanol (400 μl) and internal standard (50 μl) in 2 mL microfuge tubes then mixed for 90 min at 45°C. After extraction, an aliquot of 350 μL are transferred into a new 2-mL safe-lock tube and evaporated to dryness at 60°C under nitrogen, 150 μl of 0.1% formic acid in water are added and quickly vortexed before transferring into an HPLC auto sampler vial.
Adenosine dosage After the extraction of adenosine by means of a mixture consisting of methanol and internal standard, its concentration is measured by LC-MS/MS.
Samples are analyzed using a Shimadzu UFLC XR system consisting of two LC-20ADXR binary pumps, a DGU-20A5R vacuum degasser, and a CT0-20AC thermostated column oven and a SIL-20ACXR cooled auto sampler (Shimadzu, Marne la Vallee, France). The LC system was interfaced with an ABSciex 4500 triple quadrupole mass spectrometer (Les Ulis, France) operating with an electrospray ionization source (ESI) using nitrogen (purity: 99.99%). Ten microliters of the extracted sample were injected onto a 2.1 × 100 mm, 3 μm AtlantisR T3 column, Waters (Guyancourt, France). The starting mobile phase consisted of 3% methanol and 97% acidified water (0.1% formic acid) with a flow of 0.7 ml/min for 3.5 min. Then, the gradient of methanol was increased to 30% for 3 min. The column was re- equilibrated for 2 min to starting conditions.
- Conditions
- Syncope
- Being tested
- adenosine dosage
- Keywords
- Syncope, Adenosine
- Medical subject headings
- Syncope
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
adenosine dosageBiological
Whole blood is collected using finger puncture followed by deposit a drop of blood (20 μL) using finnpipette, on a blotting paper (Whatman 903 protein saver cards™) and dried over night at room temperature to obtain dried blood spot (DBS).
| Study group | Role | What they receive |
|---|---|---|
| Syncope | patients referred for syncope evaluation Receives: Biological: adenosine dosage | |
| No syncope | Subjects without syncope Receives: Biological: adenosine dosage |
What is being measured
The primary outcome is the main question the study is designed to answer.
Adenosine dosage
Comparison of plasmatic adenosine value observed in the syncope group with that of control group
Measured: 2 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Mar 2023
- Study start4 Oct 2021
- Primary completion31 May 2022
- Study completion31 May 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for SyncopeStudies of the same condition, open and under way.
- More trials run by Istituto Auxologico ItalianoThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case-control
- Time perspective
- Cross-sectional
- Enrolment
- 235 participants (actual)
- Target duration
- 1 Day
Sponsor and investigators
- Lead sponsor
- Istituto Auxologico Italiano
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05782712
- Sponsor's protocol ID
- 09C130
- Acronym
- BlotSpot
- Status last verified
- Feb 2024
- First submitted
- 11 Mar 2023
- Last updated
- 20 Feb 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 20 Feb 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Rapid Measurement of Adenosine Concentration in Patients With Syncope
- ClinicalTrials.gov ID
- NCT05782712
- Acronym / sponsor ID
- BlotSpot / 09C130
- Conditions
- Syncope
- Keywords
- Syncope, Adenosine
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 235 participants (actual)
- Lead sponsor
- Istituto Auxologico ItalianoUniversity, hospital or other
- Study start
- 4 Oct 2021 (actual)
- Primary completion
- 31 May 2022 (actual)
- Study completion
- 31 May 2022 (actual)
- First posted
- 23 Mar 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Until now, a barrier to the widespread evaluation of adenosine in clinical practice has been the difficulty of obtaining rapid reliable measures. A rapid method has recently been developed which consists of measuring adenosine concentration in whole blood instead of plasma by means of Mass Spectrometry (LC-MS/MS). In this study adenosine plasma levels were assessed in a larger unselected cohort of patients affected by non-cardiac syncope and compared the results with healthy controls.
Detailed description
Rationale and aim Until now, a barrier to the widespread evaluation of adenosine in clinical practice has been the difficulty of obtaining rapid reliable measures. Indeed, owing to its short half-life in the blood, adenosine is not easy to sample and measure. At the time of venepuncture, a stop solution - not commercially available - must be utilized in order to inhibit the degradation of adenosine in body fluid. After plasma deproteinization, adenosine concentration is evaluated by means of high-performance liquid chromatography.
A rapid method has recently been developed which consists of measuring adenosine concentration in whole blood instead of plasma by means of Mass Spectrometry (LC-MS/MS). In brief, whole blood is collected after finger puncture and a drop is deposited on a blot paper (Whatman). After the extraction of adenosine by means of a mixture consisting of methanol and internal standard, its concentration is measured by LC-MS/MS. This method is rapid, well accepted by the patient, not expensive, and easily replicable. Comparison between the two above-mentioned methods in 20 healthy subjects and in patients with vasovagal syncope has shown an acceptable correlation, with a r=0.65 and p<0.01. The mean adenosine concentration was significantly higher in vasovagal syncope patients than in controls (3.1 µM versus 0.60 µM, p<0.001). However, the above results need to be replicated in a larger sample of patients and controls before the blot paper method of measurement of adenosine can replace the standard method.
In this study denosine plasma levels was assessed in a larger unselected cohort of patients affected by non-cardiac syncope and compared the results with healthy controls.
Study design The rapid method of adenosine dosage in whole blood was assessed in patients with syncope and in controls. The study was performed in patients referred to Istituto Auxologico Italiano. The blood sample was be shipped to the Laboratory of Biochemistry, Timone Hospital 264 Rue Saint-Pierre, 13385 Marseille, France for analysis Syncope group: patients referred to the Syncope Unit of Auxologico with a diagnosis of possible or certain reflex syncope (class I diagnostic criteria of ESC guidelines) after exclusion of competing diagnoses.
There syncope patients are subdivided in 3 predefined subgroups:
- Subgroup A) Patients with no prodromes or very short prodromes (5 sec), normal heart and normal ECG
- Subgroup B) Patients with typical vasovagal features (orthostatic or emotional triggers, long prodromes with signs and symptoms of autonomic activation, i.e, nausea, sweating, dizziness, pallor)
- Subgroup C) Patients who do not belong to none of the above subgroups.
No syncope group: 1) Patients without a history of syncope, referred to Auxologico for other reasons; these patients have absence of severe structural heart disease and other comorbidities. 2) Healthy volunteers selected among personnel of Auxologico. The selection of these patients will be made matching them to syncope cases by age and sex.
Blood samples collection Whole blood is collected using finger puncture followed by deposit a drop of blood (20 μL) using finnpipette, on a blotting paper (Whatman 903 protein saver cards™) and dried over night at room temperature to obtain dried blood spot (DBS).
Blood samples extraction Six millimeters of dried blood spot (DBS) are cut out followed by extraction with mixture consisting of methanol (400 μl) and internal standard (50 μl) in 2 mL microfuge tubes then mixed for 90 min at 45°C. After extraction, an aliquot of 350 μL are transferred into a new 2-mL safe-lock tube and evaporated to dryness at 60°C under nitrogen, 150 μl of 0.1% formic acid in water are added and quickly vortexed before transferring into an HPLC auto sampler vial.
Adenosine dosage After the extraction of adenosine by means of a mixture consisting of methanol and internal standard, its concentration is measured by LC-MS/MS.
Samples are analyzed using a Shimadzu UFLC XR system consisting of two LC-20ADXR binary pumps, a DGU-20A5R vacuum degasser, and a CT0-20AC thermostated column oven and a SIL-20ACXR cooled auto sampler (Shimadzu, Marne la Vallee, France). The LC system was interfaced with an ABSciex 4500 triple quadrupole mass spectrometer (Les Ulis, France) operating with an electrospray ionization source (ESI) using nitrogen (purity: 99.99%). Ten microliters of the extracted sample were injected onto a 2.1 × 100 mm, 3 μm AtlantisR T3 column, Waters (Guyancourt, France). The starting mobile phase consisted of 3% methanol and 97% acidified water (0.1% formic acid) with a flow of 0.7 ml/min for 3.5 min. Then, the gradient of methanol was increased to 30% for 3 min. The column was re- equilibrated for 2 min to starting conditions.
Study design
- Observational model
- Case-control
- Time perspective
- Cross-sectional
- Target follow-up
- 1 Day
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Syncope | – | Biological: adenosine dosagepatients referred for syncope evaluation |
| No syncope | – | Biological: adenosine dosageSubjects without syncope |
Who may qualify
- Ages
- 16 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
- Study population
- Syncope group: patients referred to the Syncope Unit of Auxologico with a diagnosis of possible or certain reflex syncope (class I diagnostic criteria of ESC guidelines) after exclusion of competing diagnoses. No syncope group: 1) Patients without a history of syncope, referred to Auxologico for other reasons; these patients have absence of severe structural heart disease and other comorbidities. 2) Healthy volunteers selected among personnel of Auxologico. The selection of these patients will be made matching them to syncope cases by age and sex.
Key inclusion criteria (1 listed)
- patients referred to the Syncope Unit of Auxologico with a diagnosis of possible or certain reflex syncope (class I diagnostic criteria of ESC guidelines)
Key exclusion criteria (0 listed)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| adenosine dosageWhole blood is collected using finger puncture followed by deposit a drop of blood (20 μL) using finnpipette, on a blotting paper (Whatman 903 protein saver cards™) and dried over night at room temperature to obtain dried blood spot (DBS). | Biological | No syncope, Syncope |
Primary outcome
Adenosine dosage
Time frame: 2 hours
Comparison of plasmatic adenosine value observed in the syncope group with that of control group
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Feb 2024.
- Individual participant dataSharing planned: Yes
Related trials for Syncope
RecruitingObservational study
Genetic Markers of Cardiovascular Disease in Epilepsy
Epilepsy, Seizures
RecruitingObservational study
Whole-Body Point-of-Care Ultrasound in Older Adults Presenting to the Emergency Department After a Fall
Accidental Falls, Aged
Not yet recruiting
Head-to-Head (H2H) Comparison of Ambulatory Cardiac ECG Monitors in Japan
Atrial Fibrillation (AF), Atrial Flutter
RecruitingObservational study
Fainting Detection And Early Warning In Syncope Evaluation Study (ARISE)
Orthostatic Hypotension, Reflex Syncope
Active, not recruiting
Cardioneuroablation for Reflex Syncope and Exercise Capacity
Syncope, Vasovagal
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Syncope, run by Istituto Auxologico Italiano at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 0 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 Feb 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Adenosine dosage (time frame: 2 hours). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Feb 2024.