CataractNCT05783583

A Comparison of the Diagnostic Confidence and Image Quality Between the Eyoto Theia (RDSL) and a Predicate Device.

An observational study of Cataract, run by Eyoto Group Ltd at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

A clinical study has been identified as a requirement for the RDSL (Theia). This study involves a clinical comparison of the imaging from the RDSL with that of a predicate device. Read more about this study

Who is it for?
Ages 21 to 99 yearsHealthy volunteers can take part
Conditions the study is for
Cataract
What is being tested?
Remote Digital Slit Lamp
Type of treatment
Medical device
How many people
49 participants
Where
1 siteUnited States
Study dates
1 Oct 2022to 20 Jan 2023
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 to 99 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: community

Who may be able to join

  • Healthy eye or ocular pathology

Who cannot join

  • No exclusion other than age as above

Trial locations and contacts

1 site in 1 country.

United States1 site
  • National Vision Inc Corporate Office

    Atlanta, Georgia, 300096

Other trials in United States

About this study

Official title: A Comparison of the Diagnostic Confidence and Image Quality Between the Eyoto Theia (RDSL) Remote Digital Slit Lamp and a the Topcon SL-D2 With DC-4 Digital Attachment (Predicate Device).

A clinical study has been identified as a requirement for the RDSL (Theia). This study involves a clinical comparison of the imaging from the RDSL with that of a predicate device.

The clinical evaluation showed that there remains some residual risk in the practitioner's ability to use the imaging from the RDSL to detect pathologies at the same level as when using the imaging function on a predicate device.

Read more

The aim of this comparative study is to determine the degree, if any, of difference in using images captured from the RDSL for clinical inspection of pathologies, when compared to images captured from a predicate device.

Due to the involvement of real patients during the study, ethics approval was sought prior to commencement. This study is limited to the clinical benefits of the device.

An additional Human factors study has been conducted to assess the useability of the device Images were taken of healthy eyes and eyes with pathology (with images of several pathologies from each major pathology group to give a full range) on both the predicate device, and the RDSL.

Read the detailed description

Methodology

Overview Images were taken of 14 healthy eyes and 35 unhealthy eyes containing a range of pathologies on both the predicate device and the THEIA. The pathologies to be imaged have been carefully selected using data from the clinical evaluation, and further investigation, to ensure that all aspects of the imaging systems and ocular structures are included.

The images were taken on compliant patients in a real-world setting.

Device Selection Device Type:AC-powered remote enabled slit-lamp Manufacturer:Eyoto Product Number:THEIA (3-008-0001-03)

Intended Use:

The THEIA is intended for non-invasive examination, illumination, magnification, visualization and recording of digital photographs and video of the anterior and posterior eye segments of the human eye and its surrounding area.

Magnification:6 (base Magnification), 10X, 16X, 25X (digital steps) Filters:Blue filter,Red-free filter (digital filter),yellow Filter (fluorescein enhancement filter) Lighting:White LED,12 V, 0.7 - 1.5 A, 8.4 W Image Sensor,CMOS, 1.1", 12 Megapixel The latest pre-production version of the THEIA was used. This is representative of and has all the same functionality as, the production model.

Three individual THEIA devices of the same version were used to collect the images.

Predicate Device Device Type:AC-powered slit lamp biomicroscope Manufacturer:Topcon Product Number:Topcon SL-2G or equivalent (SL-2D with imaging attachment) Intended Use:The Slit Lamp SL-2G is an AC-powered slit lamp biomicroscope intended for use in eye examination of the anterior eye segment, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma which affect the structural properties of the anterior eye segment.

Magnification:10X, 16X, 25X Filters:Blue filter, Red-free filter, Yellow Filter (fluorescein enhancement filter) available as an accessory Lighting:White LED Image Sensor (DC-4):CMOS, 5 Megapixel

The predicate device used for this study was equivalent to the Topcon SL-2G used in the substantial equivalence investigation, used with the recommended Topcon Digital Imaging Adaptor (DC-4) in order to take the images required.

Three individual predicate devices will be used to collect the images.

Conditions
Cataract
Being tested
Remote Digital Slit Lamp
Medical subject headings
Cataract

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Remote Digital Slit LampDevice

    Slit Lamp Examination

Study groups in NCT05783583
Study groupRoleWhat they receive
Enrolled participantsAdult human subjects showing either healthy eyes or specific ocular pathologies.
Receives: Device: Remote Digital Slit Lamp

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Diagnostic Confidence

    How confident the practitioner is in respect of their identification of a pathology from image on a scale of 1-5, with 5 being completely confident and 1 being not confident. Images reviewed via online from.

    Measured: Within 1 week after data collection

  2. Image Clarity

    The rating of clarity of image by the practitioner on a scale of 1-5, with 5 being excellent clarity and 1 being low clarity. Images reviewed via online from.

    Measured: Within 1 week after data collection

  3. Identification of Pathology

    % accuracy of identification of pathology shown or healthy eye. Images reviewed via online from.

    Measured: Within 1 week after data collection

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Mar 2023
  2. Study start1 Oct 2022
  3. Primary completion5 Jan 2023
  4. Study completion20 Jan 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Cross-sectional
Enrolment
49 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05783583
Sponsor's protocol ID
EYO-CS-001.1
Status last verified
Apr 2023
First submitted
30 Jan 2023
Last updated
7 Apr 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

An observational study of Cataract, run by Eyoto Group Ltd at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 7 Apr 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Diagnostic Confidence (time frame: Within 1 week after data collection). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Apr 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in