AzTrials
AzTrials

Aortic Valve StenosisGUIDE-TAVINCT05788770

Preoperative CT-imaging with Patient-specific Computer Simulation in Transcatheter Aortic Valve Replacement

A study testing FEops HEARTGuide in people with Aortic Valve Stenosis, run by Romy Hegeman at 2 sites in 2 countries.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Combining routine preoperative CT imaging with patient-specific computer modelling predicts the interaction between different sizes of transcatheter aortic valve replacement devices at different implantation depths and the patient's unique anatomy (including post-implantation deformation) allowing preoperative… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
FEops HEARTGuide
Could I receive a placebo?
No, everyone receives an active treatment
How many people
454 participants
Where
2 sitesin 2 countries
Study dates
6 Apr 2022to 31 Dec 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Primary symptomatic severe aortic valve stenosis
  • Accepted for TAVR, either by transfemoral, transsubclavian or transapical access
  • Plan to implant one of the following transcatheter heart valves for which FEops HEARTguide™ is available (CoreValve™ Evolut™ R, and Evolut™ PRO and Evolut™ PRO+ (Medtronic, Minnesota, USA), ACURATE neo™ and ACURATE neo 2™ (Boston Scientific, Marlborough, MA, USA)
  • Informed consent
  • Exclusion Criteria:a potential subject who meets any of the following criteria will be excluded from participation in this study before randomization:
  • Previous surgical aortic valve replacement
Show all 11Show fewer
  • Permanent pacemaker at baseline
  • Emergency procedure
  • Poor CT image quality (disabling computer-simulation, i.e. generation of 3D anatomical models will not be possible with poor CT image quality), for example because of motion artifacts due to the presence of other implanted devices affecting the region of interest
  • Patient who did not agree to the informed consent and/or refused to participate
  • Patient unable to understand the informed consent/study

Who cannot join

None listed.

Trial locations and contacts

2 sites in 2 countries.

2 sites in 2 countries

Austria1 site, 1 recruiting
  • Vienna General Hospital

    Vienna

    Prof. Martin Andreas, MD, PhD

    Severin Längle, MD

    Recruiting

Other trials in Austria

Netherlands1 site, 1 recruiting
  • St. Antonius Hospital

    Nieuwegein, Utrecht, 3435 CM

    Romy Hegeman, MD

    Dirk-Jan van Ginkel, MD

    Recruiting

Other trials in Netherlands

About this study

Official title: Preoperative CT-imaging with Patient-specific Computer Simulation in Transcatheter Aortic Valve Replacement: a Randomized Controlled Trial

Combining routine preoperative CT imaging with patient-specific computer modelling predicts the interaction between different sizes of transcatheter aortic valve replacement devices at different implantation depths and the patient's unique anatomy (including post-implantation deformation) allowing preoperative evaluation of the risk for paravalvular leakage and conduction disorders.

The objective of this randomized controlled trial is to evaluate whether pre-operative CT-imaging with advanced computer modelling and simulation (FEops HEARTguide™) adequately predicts procedural outcomes in TAVR procedures, whether it leads to changes of preoperative decisions and whether or not this leads to improved outcome in TAVR procedures.

Being tested
FEops HEARTGuide
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • FEops HEARTGuideOther

    FEops HEARTGuide added to routine preoperative CT imaging. Results of the computer modelling will be discussed with TAVR implanting team prior to and during the procedure.

Study groups in NCT05788770
Study groupRoleWhat they receive
FEops HEARTGuideExperimentalDevice selection using FEops HEARTGuide: 3D anatomical analysis and simulation of transcatheter aortic valve prosthesis prior to procedure based on computed tomography.
Receives: Other: FEops HEARTGuide
Standard transcatheter aortic valve implantation (no FEops HEARTGuide)No interventionControl: standard of care, CT based device selection.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mild to severe paravalvular regurgitation

    Measured: 30-days

Secondary outcomes (13)
  1. Incidence of new conduction disorder (new-onset left bundle branch block or new-onset atrioventricular block)

    Measured: 30 days after TAVI

  2. Need for permanent pacemaker implantation

    Measured: 30 days after TAVI

  3. Preoperative valve size selection

    Measured: Preprocedural

  4. Final valve size

    Measured: Perprocedural

  5. Target implantation depth

    Measured: Preprocedural

  6. Final implantation depth

    Measured: Perprocedural

  7. Change of preoperative decision in choice of default transcather heart valve

    Measured: Preprocedural

  8. Change of preoperative decision in valve size selection

    Measured: Preprocedural

  9. Change of preoperative decision in target implantation depth

    Measured: Preprocedural

  10. Failure to implant valve

    Measured: Preprocedural

  11. Composite endpoint of major adverse cardiac and cerebrovascular events (MACCE)

    Including mortality, stroke, life-threatening bleeding, major vascular complications, valve-related dysfunction requiring repeat procedure (TAVR or SAVR), according to the VARC-3 criteria

    Measured: 30 days after TAVI

  12. Quality of life assessed by the EuroQol questionnaire

    EuroQol-5 Dimensions-5 Levels, lower levels refer to better outcomes. Visual analog scale (0-100). Higher scores refer to a better outcome.

    Measured: 90 days after TAVI

  13. Quality of life assessed by the Kansas City Cardiomyopathy Questionnaire

    All scores are represented on a 0-to-100-point scale. Higher score refers to preferabel outcomes.

    Measured: 90 days after TAVI

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Mar 2023
  2. Study start6 Apr 2022
  3. Primary completion31 Dec 2024 (estimated)
  4. Study completion31 Dec 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Multicenter, multinational, randomized controlled, open-label, trial
Masking
None (open label)
Enrolment
454 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05788770
Sponsor's protocol ID
NL77697.100.21
Acronym
GUIDE-TAVI
Status last verified
Sep 2024
First submitted
15 Mar 2023
Last updated
19 Sep 2024
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing FEops HEARTGuide in people with Aortic Valve Stenosis, run by Romy Hegeman at 2 sites in 2 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 11 inclusion and 0 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 19 Sep 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Austria, Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Romy Hegeman, MD (+31 (0)6 41 71 16 79, r.hegeman@antoniusziekenhuis.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mild to severe paravalvular regurgitation (time frame: 30-days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Sep 2024.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in