some orthodontic brands are more expensive than others, one of the primary outcomes of this study is to know if is it worth using expensive brands? will it provide better quality treatment, in particular, bond strength? The treatment duration is long therefore it is expensive, either for the orthodontist and/or the… Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
What is being tested?
Estimation of Shear Bond Strength
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteEgypt
Study dates
1 Dec 2020to 1 Dec 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • sound extracted upper and/or lower permanent premolars.
  • Intact buccal enamel surface with n erosion and cracks.
  • the teeth must be free from caries, restoration, white spot lesions, or any sign of decalcification.
  • No pretreatment with any chemical agents such as hydrogen peroxide or formalin.

Who cannot join

  • teeth with amelogenesis or dentinogenesis imperfecta.
  • labially restored teeth.
  • endodontically treated teeth.
  • teeth with fluorosis.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Future Unversity in Egypt

    New Cairo, Cairo Governorate

Other trials in Egypt

About this study

Official title: Comparison of Shear Bond Strength of Different Commercial Brands of Stainless Steel Orthodontic Brackets: An in Vitro Study

some orthodontic brands are more expensive than others, one of the primary outcomes of this study is to know if is it worth using expensive brands? will it provide better quality treatment, in particular, bond strength? The treatment duration is long therefore it is expensive, either for the orthodontist and/or the patient.

This study will be comparing the bond strength of different commercial brands of stainless steel brackets.

Read the detailed description

There are a plethora of studies in the science of orthodontics discussing different massive advances in the orthodontic adhesion concepts that allowed orthodontists to successfully bond brackets and tubes to teeth. the bond strength between the bracket and tooth should be sufficient to withstand the forces of mastication and the aggressive conditions of the oral environment. a commonly encountered problem is the failure of the bond between the bracket and tooth during treatment.

There are a lot of orthodontic in vitro studies that discussed bond failure and strength. multiple studies have studied the bracket-enamel bond strength with different curing systems and found that there was no significant difference in terms of bond strength. Several other studies discussed the effect of different adhesive systems on the bond strength to the enamel.

There are many studies that debated the shear bond strength of different metal bracket base shapes and sizes concluding that no differences in SBS for the surface area within the range of 6.82-12.35mm2 as well as the shape of the bracket base had no effect on shear bond strength.

The effectiveness or the success of the orthodontic treatment is arbitrated by achieving better aesthetics, better function, and better judgment for the patient too.

Even if there was a plethora of studies comparing the bond strength of different bracket shapes and sizes and also between metal and ceramic brackets, however, none have considered comparing shear bond strength of different bracket brands to enamel, Considering its cost and repeated failure which has its implication on both patient and orthodontist.

Being tested
Estimation of Shear Bond Strength
Keywords
Orthodontic brackets brands, Shear bond strength, Remanent adhesive Index

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Estimation of Shear Bond StrengthOther

    Also called Evaluation of Adhesive Remnant Index

    Measuring shear bond strength between the different bracket brands and the enamel will be estimated by aiming the edge of the blade of the universal testing machine at bracket-enamel interface. The force required to debond each bracket will be registered in Newtons (N), and converted to Megapascals by dividing the force registered in newtons on each bracket base area (mm2).

    After bond failure, the brackets and the enamel surfaces will be examined and assessed for the amount of adhesive remaining on the bracket bases by using digital microscope at 35x magnification. this will identify the site of bond failure.

Study groups in NCT05812456
Study groupRoleWhat they receive
3m Metal BracketsActive comparator3m Unitek Gemini Roth Stainless-Steel Brackets. it is passive Stainless-Steel components used in fixed Orthodontics appliance to help in solving malocclusions by bonding it to teeth's enamel. it acts as a means to transfers forces applied by activated archwires inserted in bracket slots to try to correct and improve the patients malocclusion problems. There are different sizes of Stainless-Steel bracket slots, There are 0.018 slot and 0.022 slot. Brackets are made of many different materials such as Stainless-Steel, ceramics, plastic or 3d printed. The most used type is metal brackets. Brackets come with built in prescriptions of torque and tip, there are two type of prescriptions: Roth and MBT
Receives: Other: Estimation of Shear Bond Strength
American Orthodontics Metal BracketsActive comparatorAmerican Orthodontics Mini Masters 0.022 Roth Stainless-Steel Brackets. it is passive Stainless-Steel components used in fixed Orthodontics appliance to help in solving malocclusions by bonding it to teeth's enamel. it acts as a means to transfers forces applied by activated archwires inserted in bracket slots to try to correct and improve the patients malocclusion problems. There are different sizes of Stainless-Steel bracket slots, There are .18 slot and .22 slot. Brackets are made of many different materials such as Stainless-Steel, ceramics, plastic or 3d printed. The most used type is metal brackets. Brackets come with built in prescriptions of torque and tip, there are two type of prescriptions: Roth and MBT
Receives: Other: Estimation of Shear Bond Strength
Fanta Metal BracketsExperimentalFanta Firmax 0.022 Roth Stainless-Steel Brackets. Fanta is a Chinese Orthodontic bracket brand that started to spread. it is passive Stainless-Steel components used in fixed Orthodontics appliance to help in solving malocclusions by bonding it to teeth's enamel. it acts as a means to transfers forces applied by activated archwires inserted in bracket slots to try to correct and improve the patients malocclusion problems. There are different sizes of Stainless-Steel bracket slots, There are 0.018 slot and 0.022 slot. Brackets are made of many different materials such as Stainless-Steel, ceramics, plastic or 3d printed. The most used type is metal brackets. Brackets come with built in prescriptions of torque and tip, there are two type of prescriptions: Roth and MBT
Receives: Other: Estimation of Shear Bond Strength
Matt Orthodontics Metal BracketsExperimentalMatt Orthodontics Pierre 0.022 Roth Metal Brackets. Matt is a Chinese Orthodontic bracket brand that started to spread. it is passive Stainless-Steel components used in fixed Orthodontics appliance to help in solving malocclusions by bonding it to teeth's enamel. it acts as a means to transfers forces applied by activated archwires inserted in bracket slots to try to correct and improve the patients malocclusion problems. There are different sizes of Stainless-Steel bracket slots, There are 0.018 slot and 0.022 slot. Brackets are made of many different materials such as Stainless-Steel, ceramics, plastic or 3d printed. The most used type is metal brackets. Brackets come with built in prescriptions of torque and tip, there are two type of prescriptions: Roth and MBT
Receives: Other: Estimation of Shear Bond Strength

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Estimation of Shear Bond Strength

    Measuring shear bond strength between the different bracket brands and the enamel will be estimated by aiming the edge of the blade of the universal testing machine at bracket-enamel interface. The force required to debond each bracket will be registered in Newtons (N), and converted to Megapascals by dividing the force registered in newtons on each bracket base area (mm2).

    Measured: 24 hours

Secondary outcomes (1)
  1. Evaluation of Adhesive Remanent Index

    ARI scale is used to asses site of bond failure After bond failure, the brackets and the enamel surfaces will be examined and assessed for the amount of adhesive remaining on the bracket bases by using digital microscope at 35x magnification.

    Measured: 24 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Apr 2023
  2. Study start1 Dec 2020
  3. Primary completion1 Dec 2022
  4. Study completion1 Dec 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05812456
Sponsor's protocol ID
FUE.REC(29)/12/2020
Status last verified
Apr 2023
First submitted
15 Mar 2023
Last updated
13 Apr 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing Estimation of Shear Bond Strength in people with Orthodontic Appliance Complication and Shear Strength, run by Future University in Egypt at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Apr 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Estimation of Shear Bond Strength (time frame: 24 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Apr 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in