Oxygen SaturationNCT05895682
A Clinical Trial to Verify the Accuracy of Seers Technology's Pulse Oximeter (mobiCARE +Pulse, MP100W) in Healthy Volunteers
A study testing mobiCARE +Pulse (MP100W) in people with Oxygen Saturation, run by Seers Technology Co., Ltd. at 1 site in South Korea.
Trial summary
It is important to evaluate the accuracy of the pulse oximeter, which is commonly used in clinical practice. The US FDA only allows the use of devices that meet the ISO 80601-2-61:2017 standard in the United States. Read more about this study
- Who is it for?
- Ages 20 to 50 yearsHealthy volunteers can take part
- Conditions the study is for
- Oxygen Saturation
- What is being tested?
- mobiCARE +Pulse (MP100W)
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 12 participants
- Where
- 1 siteSouth Korea
- Study dates
- 29 Apr 2023to 15 May 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 50 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- healthy adults between 20 and 50 years
- volunteers who have plasma proportion of carboxyhemoglobin 3%
- volunteers who have plasma proportion of methemoglobin 2%
- volunteers who have total plasma hemoglobin concentration over 10 g/dL
Who cannot join
- History of respiratory diseases
- History of cardiovascular disease
- Smokers (including ex-smokers)
- Pregnant
- History of fainting
- History of diabetes
Show all 9Show fewer
- Obesity (BMI> 30 kg/m2)
- Allen's test results, those who do not recover the color of their fingers and palms within 10 seconds
- History of allergic reaction to lidocaine, a local anesthetic
Trial locations and contacts
1 site in 1 country.
South Korea1 site
Seers Technology Co., Ltd.
Pyeongtaek-si, Gyeonggi-do, 17707
About this study
It is important to evaluate the accuracy of the pulse oximeter, which is commonly used in clinical practice. The US FDA only allows the use of devices that meet the ISO 80601-2-61:2017 standard in the United States. According to the ISO 80601-2-61:2017 standard, the accuracy of the oxygen saturation (SpO2) of the pulse oximeter should have an error range of less than 4.0% compared to the actual arterial blood oxygen saturation (SaO2) in the range of 70-100%. To prove compliance with this requirement, it is necessary to conduct a clinical trial that induces hypoxemia in healthy adults and compares and evaluates the arterial blood oxygen saturation values of the pulse oximeter's SpO2 and the arterial blood oxygen saturation values of the carbon monoxide-oxygen meter (CO-oximeter).
- Conditions
- Oxygen Saturation
- Being tested
- mobiCARE +Pulse (MP100W)
- Keywords
- Oxygen Saturation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
mobiCARE +Pulse (MP100W)Device
Volunteers were monitored using end-tidal carbon dioxide partial pressure and fraction of inspired oxygen. Each volunteer was placed in a semi-Fowler's position and connected to a breathing circuit to administer the nitrogen-air-carbon dioxide mixtures. A nose clip was applied to prevent breathing of room air. For frequent blood sampling, an arterial cannula was placed in the radial artery of each volunteer. Pulse oximeter probes were simultaneously attached to each volunteer's fingers. Each volunteer was exposed to various levels of induced hypoxia from 70~100% of SaO2. Each plateau of oxygen saturation was maintained for at least 30 s until stabilization, after which 1 ml of arterial blood was drawn into a heparinized syringe. The study period consisted of two rounds of hypoxia, and the volunteers were maintained on room air between each round. SaO2 measurements using a CO-oximeter were used as a reference for the SpO2 accuracy.
| Study group | Role | What they receive |
|---|---|---|
| Induced hypoxia | Experimental | Volunteers were monitored using end-tidal carbon dioxide partial pressure and fraction of inspired oxygen. Each volunteer was placed in a semi-Fowler's position and connected to a breathing circuit to administer the nitrogen-air-carbon dioxide mixtures. A nose clip was applied to prevent breathing of room air. For frequent blood sampling, an arterial cannula was placed in the radial artery of each volunteer. Pulse oximeter probes were simultaneously attached to each volunteer's fingers. Each volunteer was exposed to various levels of induced hypoxia from 70~100% of SaO2. Each plateau of oxygen saturation was maintained for at least 30 s until stabilization, after which 1 ml of arterial blood was drawn into a heparinized syringe. The study period consisted of two rounds of hypoxia, and the volunteers were maintained on room air between each round. SaO2 measurements using a CO-oximeter were used as a reference for the SpO2 accuracy. Receives: Device: mobiCARE +Pulse (MP100W) |
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy of SpO2
The root-mean-square of the difference between the observed pulse oximetry value (SpO2) and the carbon monoxide-oxygenometer arterial blood reference value (SRi) within the range of 70-100% of arterial oxygen saturation
Measured: 2 day
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Jun 2023
- Study start29 Apr 2023
- Primary completion14 May 2023
- Study completion15 May 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Oxygen SaturationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 12 participants (actual)
Sponsor and investigators
- Lead sponsor
- Seers Technology Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05895682
- Sponsor's protocol ID
- 2022-1657
- Status last verified
- Jun 2023
- First submitted
- 21 May 2023
- Last updated
- 8 Jun 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Jun 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Clinical Trial to Verify the Accuracy of Seers Technology's Pulse Oximeter (mobiCARE +Pulse, MP100W) in Healthy Volunteers
- ClinicalTrials.gov ID
- NCT05895682
- Acronym / sponsor ID
- 2022-1657
- Conditions
- Oxygen Saturation
- Keywords
- Oxygen Saturation
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 12 participants (actual)
- Lead sponsor
- Seers Technology Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- 29 Apr 2023 (actual)
- Primary completion
- 14 May 2023 (actual)
- Study completion
- 15 May 2023 (actual)
- First posted
- 8 Jun 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
It is important to evaluate the accuracy of the pulse oximeter, which is commonly used in clinical practice. The US FDA only allows the use of devices that meet the ISO 80601-2-61:2017 standard in the United States. According to the ISO 80601-2-61:2017 standard, the accuracy of the oxygen saturation (SpO2) of the pulse oximeter should have an error range of less than 4.0% compared to the actual arterial blood oxygen saturation (SaO2) in the range of 70-100%. To prove compliance with this requirement, it is necessary to conduct a clinical trial that induces hypoxemia in healthy adults and compares and evaluates the arterial blood oxygen saturation values of the pulse oximeter's SpO2 and the arterial blood oxygen saturation values of the carbon monoxide-oxygen meter (CO-oximeter).
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Induced hypoxia | Experimental | Device: mobiCARE +Pulse (MP100W)Volunteers were monitored using end-tidal carbon dioxide partial pressure and fraction of inspired oxygen. Each volunteer was placed in a semi-Fowler's position and connected to a breathing circuit to administer the nitrogen-air-carbon dioxide mixtures. A nose clip was applied to prevent breathing of room air. For frequent blood sampling, an arterial cannula was placed in the radial artery of each volunteer. Pulse oximeter probes were simultaneously attached to each volunteer's fingers. Each volunteer was exposed to various levels of induced hypoxia from 70~100% of SaO2. Each plateau of oxygen saturation was maintained for at least 30 s until stabilization, after which 1 ml of arterial blood was drawn into a heparinized syringe. The study period consisted of two rounds of hypoxia, and the volunteers were maintained on room air between each round. SaO2 measurements using a CO-oximeter were used as a reference for the SpO2 accuracy. |
Who may qualify
- Ages
- 20 to 50 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (4 listed)
- healthy adults between 20 and 50 years
- volunteers who have plasma proportion of carboxyhemoglobin 3%
- volunteers who have plasma proportion of methemoglobin 2%
- volunteers who have total plasma hemoglobin concentration over 10 g/dL
Key exclusion criteria (9 listed)
- History of respiratory diseases
- History of cardiovascular disease
- Smokers (including ex-smokers)
- Pregnant
- History of fainting
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| mobiCARE +Pulse (MP100W)Volunteers were monitored using end-tidal carbon dioxide partial pressure and fraction of inspired oxygen. Each volunteer was placed in a semi-Fowler's position and connected to a breathing circuit to administer the nitrogen-air-carbon dioxide mixtures. A nose clip was applied to prevent breathing of room air. For frequent blood sampling, an arterial cannula was placed in the radial artery of each volunteer. Pulse oximeter probes were simultaneously attached to each volunteer's fingers. Each volunteer was exposed to various levels of induced hypoxia from 70~100% of SaO2. Each plateau of oxygen saturation was maintained for at least 30 s until stabilization, after which 1 ml of arterial blood was drawn into a heparinized syringe. The study period consisted of two rounds of hypoxia, and the volunteers were maintained on room air between each round. SaO2 measurements using a CO-oximeter were used as a reference for the SpO2 accuracy. | Device | Induced hypoxia |
Primary outcome
Accuracy of SpO2
Time frame: 2 day
The root-mean-square of the difference between the observed pulse oximetry value (SpO2) and the carbon monoxide-oxygenometer arterial blood reference value (SRi) within the range of 70-100% of arterial oxygen saturation
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Jun 2023.
- Individual participant dataSharing planned: No
Related trials for Oxygen Saturation
RecruitingObservational study
Development and Validation of a Multimodal Deep Learning Model Using Peripheral Oxygen Saturation and Ballistocardiography Signals for Predicting Apnea-Hypopnea Index in Obstructive Sleep Apnea
Obstructive Sleep Apnea
Recruiting
Optimization of Saturation Targets And Resuscitation Trial (OptiSTART)
Premature Infants, Bronchopulmonary Dysplasia
Active, not recruiting
Influence of FreeO2 on Percentage of Time Within Oxygen Saturation Target Using Noninvasive Ventilation (NIV) and Continuous Positive Airway Pressure (CPAP) for Patients Admitted for AECOPD or Bariatric Surgery
COPD Exacerbation, Oxygen Toxicity
Recruiting
WIN Ratio Analysis to Determine a Strategy of Non- Invasive SUpport for Respiratory Failure in the EmeRgency Department
Acute Hypoxic Respiratory Failure, Acute Respiratory Distress Syndrome (ARDS)
Not yet recruiting
Effect of Nurse-Directed Therapeutic Positioning in Children With Pneumonia
Pediatric Pneumonia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing mobiCARE +Pulse (MP100W) in people with Oxygen Saturation, run by Seers Technology Co., Ltd. at 1 site in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 8 Jun 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy of SpO2 (time frame: 2 day). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jun 2023.