AzTrials
AzTrials

SpasticityNCT05926596

Leg Stretching Using an Exoskeleton on Demand for People With Spasticity

A study testing Wearable Robotic Exoskeleton in people with Spasticity and Movement Disorders, run by VA Office of Research and Development at 1 site in United States.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

The purpose of this research study is to develop a protocol using a fully wearable, portable lower-limb exoskeleton for improving leg and walking function in people with movement disorders. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Spasticity, Movement Disorders, Spinal Cord Injury
What is being tested?
Wearable Robotic Exoskeleton
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10 participants
Where
1 siteUnited States
Study dates
9 Feb 2026to 30 Apr 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Veteran individuals with spasticity due to spinal cord injury (SCI) at least 6 months post SCI
  • Capable of providing informed consent and reporting age, gender, and neurological condition
  • Neurologically stable (>6 months post-SCI) and can wear the device and the sensors, provide written informed consent, and follow instruction

Who cannot join

  • Participants should not experience another neurological disorder except their primary diagnosed neurological condition (spinal cord injury)
  • Participants should not be pregnant
  • Participants should weigh less than 300 lbs
  • Participants should not have experienced signs of hip/knee pain during the past 2-3 weeks that limits mobility (i.e., reaching, walking, lifting, etc.)
  • Participants should be recovered from any previous surgical interventions, joint injuries, muscle strain, or extreme muscle soreness following surgery
  • Participants should not take medications known to affect bone metabolism, muscle strength or cardiovascular performance or have any ailments causing high fever, high blood pressure, or high heart rate

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Steven W Brose contact

(315) 425-4400

steven.brose@va.gov

United States1 site, 1 recruiting
  • Syracuse VA Medical Center, Syracuse, NY

    Syracuse, New York, 13210-2716

    Steven W Brose, (315) 425-4400, steven.brose@va.gov

    Steven W Brose

    Recruiting

Other trials in United States

About this study

Official title: Leg Stretching Using a Controllable Wearable Exoskeleton on Demand for People With Spasticity

The purpose of this research study is to develop a protocol using a fully wearable, portable lower-limb exoskeleton for improving leg and walking function in people with movement disorders. The study investigates the effects of wearing the device during a set of experiments including leg stretching, treadmill walking and overground walking in muscle activity, joint motion, and gait performance. The goal is to develop an effective lower-limb strategy to restore lost leg function (e.g., range of motion) and gait ability, and improve quality of life in people with movement deficits following a neurological disorder.

Read the detailed description

People with neurological conditions, including individuals with upper motor neuron injury, experience motor and sensory deficits, muscle weakness, limited range of motion, low weight-bearing capacity, and impaired balance that limit ambulation and interfere with the ability to perform activities of daily living. Lower-limb rehabilitation robots can assist with physical therapy and alleviate the burden of caregivers and nurses. Thus, the goal of this project is to develop wearable and portable technology to assist leg motion and stretching, and correspondingly activate muscles in people with neurological conditions who experience spasticity.

Spasticity results from increased muscle tone and interferes with the ability to functionally use voluntary muscle contraction for limb coordination and range of motion, which limits body transfers, ambulation, and exercise. Severe or intractable spasticity can lead to loss of body control and balance, resulting in falls and injuries, pressure injury of the skin, contractures, pain, wheelchair seating difficulties, in addition to other problems. Existent treatments to manage spasticity and overcome functional deficits related to spasticity include medications, neurosurgery, whole body or limb vibration, physical therapy, passive cycling, functional electrical stimulation (FES), along with other methods. However, medications may induce significant side effects including drowsiness, malaise, muscle weakness and pain (e.g., at the injection site); in addition, their effectiveness is sensitive to dosing fluctuations. Neurosurgery and direct spinal cord stimulation can treat intractable or focal spasticity, but they carry surgical risks, and their long-term benefits vary across individuals.

Stretching can decrease the excitability of motor neurons, maintain the viscoelastic properties of muscles and joints, provide relief from muscles spasms, and improve range of motion and gait function; further, stretching can be combined with oral medications to manage spasticity. Stretching is performed routinely by therapists, nurses, and caregivers to provide muscle stretching or preserve range of motion in joints with relatively low adverse effects. However, providing on-demand, reliable, manual limb stretching throughout the day and night imposes a heavy burden on caregivers and nurses both at home and in medical facilities. Hence, a critical need exists to develop a wearable approach to applying on-demand, safe, and customized dynamic stretching to manage spasticity after SCI, which can minimize the burden of caregivers and nurses.

This project exploits the recent technological advances in wearable sensors and fully wearable exoskeletons with reduced form factor and weight, which the investigators have not exploited (nor developed) in our previous research protocols at Syracuse University. These novel wearable exoskeletons are smart garments that conform to the human body and provide leg assistance in people with muscle weakness or hemiplegia. Light-weight exoskeletons have the potential to expand the breadth of tasks and environments in which exoskeletons are used for. Hence, this project introduces a lightweight, wearable exoskeleton to assist leg motion and stretching (e.g., targeting people with spasticity) under different postures (e.g., while lying down on a mat or bed, sitting on a chair or in a wheelchair).

Aim 1 characterizes the performance of the wearable device and its closed-loop control algorithm to apply precise adjustments for safe, automatic limb stretching and motion of single joints (e.g., joints in isolation while sitting or lying on a mat). The methods in this aim include the following: 1) design a control algorithm to apply safe leg forces exploiting joint kinematics and inertial feedback data using wearable sensors and 2) examine the magnitude and timing of the applied forces to the hip, knee and ankle joints, and toes. The research tasks in this aim will enable the customization of the applied forces across participants.

Aim 2 expands the implementation of the closed-loop controller from Aim 1 to different body postures and activities that involve multi-joint control. Participants wear the device to experience the applied forces by the wearable exoskeleton while lying down on a bed/mat or sitting down. Since the device is fully wearable, it serves as a powerful tool to examine the motion and limb-stretching of individuals with neurological conditions and spasticity. Thus, the device is not limited to fixed/stationary experimental conditions.

The last aim collects qualitative data from participants, caregivers, nurses, and clinicians (if involved) about the ease of use and satisfaction from using the wearable device. Questionnaires and surveys are used to gather qualitative data. Ease of use of the wearable device is assessed by examining if the protocol can be implemented within the expected duration including the time to don and doff the exoskeleton; further, it will be determined if the adherence to the protocol is achieved for all participants.

Research Design- Methodology

A candidate for the study will be asked to complete a Screening Questionnaire by phone or in person to check for eligibility. If the potential participant is eligible to enroll in the study, the participant will receive more information regarding the enrollment process. Participant will then complete a Demographics Questionnaire and answer questions about personal health and physical functioning.

Each lab visit may take up to 2 hours (including fitting the device, warm-up, testing procedures, rest breaks, unfitting the device, and removing the electrodes and wearable sensors).

Raw data will be collected from wearable sensors including the following: joint angles, 3D leg motion, muscle electromyography (EMG), and motor currents from the wearable device. Digital data recorded from experiments will be stored in .mat files (or .csv), password protected. There are no biological specimens collected.

Metadata will be applied to each component of the dataset following acquisition to ensure data is prepared for proper archiving. Metadata will include type, format, date, time, storage location, and context of data. Data generated during this project use conventional digital formats including:

  • MS Word, Power Point, Excel, Portable Data Format (PDF), and LaTeX (tex) files
  • Graphics, figures, tables, animations, videos from tests (jpeg, png, eps, mp4 files)
  • Code including MATLAB/Simulink files, C++ code, and ASCII text files

The paper participation records will be kept in locked file cabinets in the laboratory and/or offices, and the digital data will be stored on password-protected computers/servers or encrypted electronic storage devices in the offices and laboratory of the PIs' research team.

Being tested
Wearable Robotic Exoskeleton
Keywords
exoskeleton, spasticity
Medical subject headings
Muscle Spasticity, Movement Disorders, Spinal Cord Injuries

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Wearable Robotic ExoskeletonDevice

    • Participant preparation, placement of wearable sensors and monitoring, and wearable device fitting.
    • Lower-limb joint rotations and leg stretching protocol (40-60 minutes). The wearable exoskeleton and its control algorithm are evaluated to rotate leg joints and apply stretching similarly to the forces applied by nurses and caregivers when providing manual forces. Joint rotation and limb stretching is conducted while participants sit down (e.g., in a wheelchair, on a chair, on one side of a bed, or on a clinical mat) or lay down on a bed/mat. The protocol involves ankle plantarflexion and dorsiflexion, knee extension, hip flexion with the knee flexed, and toe flexion and extension (bilaterally) assisted by the exoskeleton, and each movement is repeated at a low-to-moderate rate of 10-30 cycles/minute.
    • Treadmilll and Overground Walking (60-90 minutes including rest periods)
    • Cool down (5-10 minutes)
Study groups in NCT05926596
Study groupRoleWhat they receive
Robotic ExoskeletonExperimentalAll participants will be interfered with a wearable robotic exoskeleton.
Receives: Device: Wearable Robotic Exoskeleton

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. 3D postures

    3D postures will be assessed using the device, combining measurements of multiple joints in space

    Measured: Through study completion, an average of 24 weeks

  2. Joint angles

    Hip and knee joint angles measured in degrees will be assessed using the device

    Measured: Through study completion, an average of 24 weeks

  3. Joint angular velocities

    Hip and knee joint velocities measured in radians per second or degrees per second will be assessed using the device

    Measured: Through study completion, an average of 24 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Jul 2023
  2. Study start9 Feb 2026
  3. Primary completion30 Apr 2027 (estimated)
  4. Study completion30 Apr 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
All participants will be interfered with with a wearable robotic exoskeleton.
Masking
None (open label)
Enrolment
10 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05926596
Sponsor's protocol ID
A4652-P
Other IDs
1I21RX004652-01A1
Status last verified
Sep 2026
First submitted
22 Jun 2023
Last updated
2 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in