Amputation, SurgicalKSHNCT05990062
Improving Prosthetic Arms for Amputee: A Better Fit and More Functionality
A study testing K-Socket-Harness in people with Amputation, Surgical, run by VA Office of Research and Development at 1 site in United States.
Trial summary
This research and development will improve upon and investigate the potential validity of an innovative new transradial socket and harness design (the KSH system) that offers an alternative to standard hard sockets and rubber liners with a hybrid polymer and textile-based design derived from advanced athletic shoe… Read more about this study
- Who is it for?
- Any ageHealthy volunteers can take part
- Conditions the study is for
- Amputation, Surgical
- What is being tested?
- K-Socket-Harness
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 25 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Jun 2025to 30 Sep 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- Healthy volunteers accepted
- Child, Adult, Older adult
Who may be able to join
- Unilateral transradial arm amputation
- Possession of a functioning and wearable previously fit prosthetic arm of any type
- Residual limb length of at least 4 inches from the lateral epicondyle to the distal tip
- Residual limb length less than or equal to that allowing a clearance of 1.5 inches from a fitted wrist
- Must have at least 5-years of prosthetic use experience (For Phase 1 \& 2)
- Must have at least 1-year of prosthetic use experience (For Phase 3 only)
Who cannot join
- Current open sores or incisions, Heterotopic ossification (HO), traumatic neuromas, or any other condition preventing the wearing of a prosthetic socket
- Residual limb length less than 4 inches
- Residual limb length greater than that allowing 1.5 inches clearance from a fitted wrist.
- The investigators will make every effort to recruit Veterans. If its found that it is not possible to recruit enough Veterans, the investigators will perform a non-Veteran amendment to this protocol.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
United States1 site, 1 recruiting
- Recruiting
VA Pittsburgh Healthcare System University Drive Division, Pittsburgh, PA
Pittsburgh, Pennsylvania, 15240
Elizabeth B Toth, BA, (412) 954-5382, elizabeth.toth2@va.gov
Rory A Cooper, PhD
About this study
Official title: The Advancement of a New Variable-Compliance Socket and Frame System for Transradial Amputees to Optimize Socket Fit and Upper Limb Function
This research and development will improve upon and investigate the potential validity of an innovative new transradial socket and harness design (the KSH system) that offers an alternative to standard hard sockets and rubber liners with a hybrid polymer and textile-based design derived from advanced athletic shoe technology. The project consists of designing, custom fitting and evaluating the function and comfort of the this new novel system. The study will take place in 3 phases; Phase 1, five experienced Veterans with transradial arm amputations will be recruited to provide guidance and to assist with the design and development. Experienced end-user Veterans and Clinical staff will work together to assist with design, develop the fitting process and working with engineers on the design of a completely digital fitting device for measuring the residual limb and locating bony prominences of the limb to inform the socket design. Phase 2, testing and assessment, the design and process validation will take place with the five Veteran upper transradial arm amputees Phase 3, an additional 20 Veterans with transradial arm amputations will be recruited and fit with the KSH system and undergo a series of evaluative tests. Veterans will perform a series of static and dynamic tasks to evaluate function, comfort and load bearing failure. The primary goal of this study is to improve upon the current preliminary prototype and to test it with a broader population of potential users to help advance the engineering and design, and to learn the potential to fit a range of Veterans with transradial amputations.
Read the detailed description
Acceptance of prosthetic arms has long been a problem for clinical prosthetics, and recent studies indicate that recent advancements have done little to improve usage. Objections related to the fit and comfort of prosthetic arms remain the main reasons cited for the disuse of the devices, numbering nine of the top ten reasons cited for abandonment in a survey study. By addressing the literal point of pain for these users, the investigators hope to increase use and acceptance, allowing existing devices to have more positive impact on Veterans' lives. The breathability of composite sockets has been an acknowledged problem nearly since their development by the VA in the 1940s. Indeed, while the VA successfully developed a breathable composite socket very early on, it was quickly abandoned after it was discovered that the breathable composite recreated the problems with odor and cleanliness with leather sockets that the composites had been developed to solve. Industry leader Otto Bock discovered the same thing when it developed a porous silicone liner decades later. While VA and civilian providers were successful in replacing leather sockets with composites through the innovations in composites and other materials following World War II. Prosthetic clinics used to employ leatherworkers skilled in the art of making custom sockets and braces out of these traditional materials, but these services have disappeared along with the Veterans demanding them, and the workers capable of delivering them. By taking advantage of the benefits of the advanced materials and construction techniques that have replaced leather in the athletic shoe industry over the last seventy-five years, the investigators hope to restore much of the comfort and fit of these extinct socket designs, while at the same time delivering the improvements that have been delivered by the athletic shoe industry and advances in design and manufacturing over the same period. Lim design is working on a textile based prosthetic socket; however, the approach differs from the investigators': 1) The Lim design is not intended or currently suitable for upper limbs; 2) While a textile design, the Lim design cannot dynamically change in volume through the range of motion and constrains motion similar to any other socket once it has been adjusted; 3) The textile design of the Lim socket is nether breathable nor wicking and is designed to be used with silicone and/or gel liners, hence suffers from the same deficiencies with respect to heat and moisture management as traditional sockets. Lim Innovations and Ossur have publicly stated that they do not intend to pursue further innovations in the upper limb market. These frank admissions make it clear that the development of orphan devices for Veterans, must become the responsibility of the VA, whose goals for serving Veterans are sometimes in contrast with and not limited to the constraints of large and profitable markets. VA in collaboration with small companies can help fill this much needed void for innovation. VA has shown leadership in related domains with the research and design for ultralight wheelchairs, alternative controls for powered wheelchairs, and adaptive sports and recreation equipment, all of which eventually assisted the broader populations of Americans with disabilities. Harness discomfort is just as detrimental to acceptance as poor socket-body interface and can lead to contralateral damage to the axilla. Indeed, one recent study concluded that there was no acceptable level of force at which a body powered prosthesis could be operated pain and fatigue free with a traditional harness. While the conclusions of this study obviously contradict the staying power of the body powered prosthesis and harness system accepted by more than 90 per cent of the roughly half of users who accept a prosthesis at all, it does indicate that there is substantial improvement to be made in harnessing that could significantly improve both acceptance and comfort of the users who have been willing to tolerate the uncomfortable standard of care that has seen slow progress for decades.
Study Objectives and Hypothesis:
Specific Aim 1: Improve and develop the design and systems for fitting an innovative new transradial suspension design based on currently available technology used in athletic shoe construction.
- Design Criteria 1a: Optimize CAD documentation by revising and translating the current Autodesk Fusion 360 design to SolidWorks, aiding customization and improving design for manufacture.
- Design Criteria 1b: Verify that the currently Direct Metal Laser Sintered (DMLS) printed wrist and quick release can be efficiently and effectively CNC machined.
- Design Criteria 1c: Create fixturing and finalize CNC programming for manufacture, including the specification of manufacturing tolerances to ensure proper fit of components.
- Design Criteria 1e: Verify forearm and elbow counter parts-currently printed in Multijet Fusion (MJF)-in Selective Laser Sintering (SLS) or Fused Deposition or Fused Filament (FDM/FFF) Nylon material.
- Design Criteria 1f: Automate adaptation of the design through plugin and API development.
- Design Criteria 1g: Optimize production of 2D textile patterns with, for example, ExactFlat.
- Design Criteria 1h: Design a digital or Brannock-like fitting device for measuring the residual limb and locating bony prominences of the limb to inform the socket design.
- Design Criteria 1i: Design the device to weigh less than 2 pounds in total. The design will address common limitations of current upper-limb prostheses by improving comfort, range of motion, function, and sustained prosthesis use among individuals with transradial amputation.
Specific Aim 2: Verify performance gains for the innovative KSH system that can be delivered to Veterans. The new design is expected to significantly exceed the performance of the standard-of-care prosthesis in quantitative measures.
- Hypothesis 2a (H2a): That the improved KSH will provide a higher tensile static load bearing capacity before failure than the current standard-of-care prosthesis.
- Hypothesis 2b (H2b): That the improved KSH will provide greater tensile loads in a dynamic environment. The KSH system will allow users to perform better on a rowing ergometer 10-minute test before failure than the current standard-of-care prosthesis, as measured using strokes per minute, power in Watts, distance in meters, maximal force, and time before failure.
- Hypothesis 2c (H2c): The improved KSH will provide a greater range of motion in flexion/extension than the current standard-of-care prosthesis.
- Hypothesis 2d (H3d): Participants will require less time for donning/doffing the KSH than their current standard-of-care prosthesis.
Specific Aim 3: Verify functionality of the KSH system through testing with end-users.
- Hypothesis 3a (H3a): Participants will report high usability with setup and operation of the device (>80 on the System Usability Scale (SUS)).
- Hypothesis 3b (H3b): Participants will report significantly higher Socket Comfort Scores (SCS) with the KSH than their current standard-of-care prosthesis.
- Hypothesis 3c (H3c): Lower weight will correlate with greater user satisfaction, and the KSH will be statistically and clinically significantly lighter than participants' current devices.
- Hypothesis 3d (H3d): Participants will report that they would switch to the new design or have an additional prosthesis with the new design.
- Hypothesis 3e (H3e): Participants will report significantly higher Orthotics and Prosthetics User Survey (OPUS) scores with the KSH than their current standard-of-care prosthesis.
Relevance to Veterans: According to the DoD/VA Extremity Amputation Center of Excellence there were about 3,000 Veterans with transradial amputations enrolled for VA Healthcare in FY21, out of about 62,000 Veterans with limb amputations enrolled for VA healthcare. Veterans with arm amputations from Post-911 conflicts number just over 200, and because the total number of Veterans missing arms is demographically small, this very fact has severely limited innovation in the field of prosthetic arms. Those missing at least all five fingers of a hand are among the VA's most significantly disabled Veterans, rated at 80 per cent disabled alone for the loss of a dominant hand. Many arm amputees are eligible for Special Monthly Compensation as well as vehicle and housing modifications, reflecting the degree to which these Veterans' lives are impacted by the impairment. Indeed, even among the civilian population, arm amputation is rare enough to easily meet the FDA's medical orphan criteria of fewer than 200,000 patients, though the FDA's orphan drug law specifically excludes medical devices, and the FDA has a lower device threshold of 8,000 patients, further limiting innovation. The NIH's Genetic and Rare Diseases Information Center (GARD) lists limb absence as a rare birth condition but doesn't mention the same disability acquired by trauma or through other diseases, such as cancer, which is the second most common cause despite the small total number from all causes. While the subject design can be extended to other levels of amputation, this study will focus on transradial, or below elbow amputees. This population represents approximately seventy-five per cent of the VA population of Veterans with arm amputations, a subset that is also much more likely to successfully wear a prosthetic arm. Over 90% of these users choose body powered. The design could be extended to other Veteran populations, including people with lower-limb amputations and other levels of amputation, potentially increasing the benefit by offering the same benefits to those Veterans. By targeting the portion of an orphan population that is already more likely to use the device for which improvement is sought, and by targeting the concerns that are most likely to lead to abandonment, this research stands to increase acceptance and therefore access to activities of daily living, employment and recreation that can improve quality of life for some of the VA's most impaired patients. Success could then also be translated to larger populations with similar needs. The proposed design is intended to address more than half the total population of Veterans with upper limb amputations and could with additional research and development be designed in the future for other levels of amputation, including lower limb and myoelectric upper limb use.
- Conditions
- Amputation, Surgical
- Being tested
- K-Socket-Harness
- Keywords
- function, breathability, comfort, transradial
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
K-Socket-HarnessDevice
Also called KSH System
A transradial socket and harness design that offers a hybrid polymer and textile-based design derived from advanced athletic shoe technology. The KSH integrated socket, frame, and wrist, the "variable compliance prosthetic socket with breathable matrix," creates a dynamic and secure attachment with a combination of two lacing systems. The lacing systems lengthen and shorten six flexible hinges at the elbow, maintaining a secure attachment throughout the range of motion and accounting for volume changes in the soft tissue of the elbow that would otherwise restrict range of motion or cause the socket to separate from the residual limb.
| Study group | Role | What they receive |
|---|---|---|
| Verify performance gains for the innovative KSH system that can be delivered to Veterans. The new de | Experimental | The investigators will perform several functional tests of the both the KSH system and the standard of care prosthesis: tensile static load bearing capacity before failure, test rowing ergometer 10-minute test before failure measured using strokes per minute, power in Watts, distance in meters, maximal force, and time before failure, range of motion in flexion/extension, and donning/doffing time. Receives: Device: K-Socket-Harness |
| Verify functionality of the KSH system through testing with end-users. | Experimental | The investigators will use System Usability Scale (SUS) to assess high usability with setup and operation of the device. The investigators will assess Comfort Scores (SCS), evaluate weight and correlate it with user satisfaction. The investigators will report selection outcome between new design and current design. The investigators will asses 1) functional status, (2) health- related quality of life, and (3) satisfaction with services and (4) device scores through the Orthotics and Prosthetics User Survey (OPUS). Receives: Device: K-Socket-Harness |
What is being measured
The primary outcome is the main question the study is designed to answer.
Static tensile load bearing capacity to reach a 50-pound load on an industrial scale
The investigators will test tensile static load bearing capacity up to a 50 -pound load or to failure. The Veteran will stand safely on an industrial scale with the arm extended at their side and weight will be added to the distal end of the prosthesis until the goal is met or the prosthesis fails. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 20 minutes
Elbow range of motion in flexion/extension
The investigators will measure range of motion (in degrees) in flexion/extension with a standard goniometer. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 30 minutes
Donning/doffing prosthesis
The investigators will record the time it takes to donn/doff each prosthesis for both the KSH socket and the standard socket.
Measured: 30 minutes
Power in Watts generated on rowing machine
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test before failure, as measured using power in Watts. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 10 minutes
Strokes per 10-minute period
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test before failure, as measured using strokes per minute. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 10 minutes
Distance rowed in meters
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test measuring distance in meters before failure or to time expiration. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 10 minutes
Maximal force before failure
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test measuring maximal force (Newton) before failure. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 10 minutes
Total time before failure
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test recording the time (in minutes and seconds) before failure. The investigators will perform the task on both the KSH socket and the standard socket.
Measured: 10 minutes
Secondary outcomes (5)
Usability of prosthesis using the System Usability Score (SUS) on scale from 0-100
Participants will report usability with setup and operation of the device from ten questions using a five point Likert scale. The higher the score, the more usable (user friendly) the device is rated by the Veteran. The investigators would like the KSH system to score >80 on the System Usability Scale (SUS)).
Measured: 15 minutes
Socket Comfort Scores (SCS) on a scale from 0-10
Participants will report Socket Comfort Scores (SCS) after wearing and testing of the devices for both with the KSH and current standard-of-care prosthesis by using an 11 point scale, (0-10) zero being the most uncomfortable socket fit you can image, and 10 being the most comfortable socket fit.
Measured: 30 minutes
Weight of device in pounds
The investigators will correlate the weight of the prosthesis in pounds with user satisfaction of both the KSH device and the participants' current device.
Measured: 30 minutes
Participant preference
The investigators will ask the participant which device design they prefer to use.
Measured: 10 minutes
Orthotics and Prosthetics User Survey (OPUS)
The investigators will ask the participant to complete the questionnaire focusing on five modules; lower and upper extremity functional status (LEFS and UEFS), client satisfaction with device and services (CSD and CSS), and the health related quality of life (HRQoL) Scores are based on a 100 point scale. The higher the score indicates a better outcome.
Measured: 1 hour
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Aug 2023
- Study start1 Jun 2025
- Primary completion31 May 2028 (estimated)
- Study completion30 Sep 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Amputation, SurgicalStudies of the same condition, open and under way.
- More trials run by VA Office of Research and DevelopmentThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Model description
- The protocol consists of three phases with iterative design and development process involving input from Veterans with disabilities at various stages. In addition, 5 certified Prosthetists with at least five years of experience working with Veterans with transradial arm amputations will also be recruited to provide guidance and to assist with the design and development of the K-Socket Harness (KSH).
- Masking
- None (open label)
- Enrolment
- 25 participants (estimated)
Sponsor and investigators
- Lead sponsor
- VA Office of Research and Development
- Sponsor type
- US federal agency
- Collaborators
- Stumpworx LLC
- Responsible party
- Sponsor
- Investigators
- Rory A Cooper, PhD, Principal investigator, VA Pittsburgh Healthcare System University Drive Division, Pittsburgh, PA
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05990062
- Sponsor's protocol ID
- A4257-R
- Acronym
- KSH
- Status last verified
- Jul 2026
- First submitted
- 18 Jul 2023
- Last updated
- 24 Jul 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: Any information obtained from this study will be treated as confidential and will be safeguarded in accordance with the HIPAA privacy and security regulations. Research records may be released or disclosed if required by federal law. Records will be coded by assigning a case number and the information linking the case number to the subject's identity will be stored electronically on the VAPHS network. Any protected health information (PHI) stored electronically is in compliance with the HIPAA security rule. Study subjects will not be specifically identified in any publication of research results. Paper source documents of the coded research records will be kept in file cabinets within a locked file room. Any records which contain direct subject identifiers will be stored separately, with a different identification code, in a locked file cabinet within a locked file room. Records will be maintained in accordance with the Veterans Health Administration (VHA) Records Control Schedule.
Publications
Salminger S, Stino H, Pichler LH, Gstoettner C, Sturma A, Mayer JA, Szivak M, Aszmann OC. Current rates of prosthetic usage in upper-limb amputees - have innovations had an impact on device acceptance? Disabil Rehabil. 2022 Jul;44(14):3708-3713. doi: 10.1080/09638288.2020.1866684. Epub 2020 Dec 30.
PubMed 33377803Biddiss E, Chau T. Upper-limb prosthetics: critical factors in device abandonment. Am J Phys Med Rehabil. 2007 Dec;86(12):977-87. doi: 10.1097/PHM.0b013e3181587f6c.
PubMed 18090439Hichert M, Vardy AN, Plettenburg D. Fatigue-free operation of most body-powered prostheses not feasible for majority of users with trans-radial deficiency. Prosthet Orthot Int. 2018 Feb;42(1):84-92. doi: 10.1177/0309364617708651. Epub 2017 Jun 16.
PubMed 28621577Hanspal RS, Fisher K, Nieveen R. Prosthetic socket fit comfort score. Disabil Rehabil. 2003 Nov 18;25(22):1278-80. doi: 10.1080/09638280310001603983.
PubMed 14617445Heinemann AW, Bode RK, O'Reilly C. Development and measurement properties of the Orthotics and Prosthetics Users' Survey (OPUS): a comprehensive set of clinical outcome instruments. Prosthet Orthot Int. 2003 Dec;27(3):191-206. doi: 10.1080/03093640308726682.
PubMed 14727700Dillingham TR, Pezzin LE, MacKenzie EJ. Limb amputation and limb deficiency: epidemiology and recent trends in the United States. South Med J. 2002 Aug;95(8):875-83. doi: 10.1097/00007611-200208000-00018.
PubMed 12190225
Study at a glance
From the registry record, last updated by the sponsor on 24 Jul 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Advancement of a New Variable-Compliance Socket and Frame System for Transradial Amputees to Optimize Socket Fit and Upper Limb Function
- ClinicalTrials.gov ID
- NCT05990062
- Acronym / sponsor ID
- KSH / A4257-R
- Conditions
- Amputation, Surgical
- Keywords
- function, breathability, comfort, transradial
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 25 participants (estimated)
- Lead sponsor
- VA Office of Research and DevelopmentUS federal agency
- Collaborators
- Stumpworx LLC
- Study start
- 1 Jun 2025 (actual)
- Primary completion
- 31 May 2028 (estimated)
- Study completion
- 30 Sep 2028 (estimated)
- First posted
- 14 Aug 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This research and development will improve upon and investigate the potential validity of an innovative new transradial socket and harness design (the KSH system) that offers an alternative to standard hard sockets and rubber liners with a hybrid polymer and textile-based design derived from advanced athletic shoe technology. The project consists of designing, custom fitting and evaluating the function and comfort of the this new novel system. The study will take place in 3 phases; Phase 1, five experienced Veterans with transradial arm amputations will be recruited to provide guidance and to assist with the design and development. Experienced end-user Veterans and Clinical staff will work together to assist with design, develop the fitting process and working with engineers on the design of a completely digital fitting device for measuring the residual limb and locating bony prominences of the limb to inform the socket design. Phase 2, testing and assessment, the design and process validation will take place with the five Veteran upper transradial arm amputees Phase 3, an additional 20 Veterans with transradial arm amputations will be recruited and fit with the KSH system and undergo a series of evaluative tests. Veterans will perform a series of static and dynamic tasks to evaluate function, comfort and load bearing failure. The primary goal of this study is to improve upon the current preliminary prototype and to test it with a broader population of potential users to help advance the engineering and design, and to learn the potential to fit a range of Veterans with transradial amputations.
Detailed description
Acceptance of prosthetic arms has long been a problem for clinical prosthetics, and recent studies indicate that recent advancements have done little to improve usage. Objections related to the fit and comfort of prosthetic arms remain the main reasons cited for the disuse of the devices, numbering nine of the top ten reasons cited for abandonment in a survey study. By addressing the literal point of pain for these users, the investigators hope to increase use and acceptance, allowing existing devices to have more positive impact on Veterans' lives. The breathability of composite sockets has been an acknowledged problem nearly since their development by the VA in the 1940s. Indeed, while the VA successfully developed a breathable composite socket very early on, it was quickly abandoned after it was discovered that the breathable composite recreated the problems with odor and cleanliness with leather sockets that the composites had been developed to solve. Industry leader Otto Bock discovered the same thing when it developed a porous silicone liner decades later. While VA and civilian providers were successful in replacing leather sockets with composites through the innovations in composites and other materials following World War II. Prosthetic clinics used to employ leatherworkers skilled in the art of making custom sockets and braces out of these traditional materials, but these services have disappeared along with the Veterans demanding them, and the workers capable of delivering them. By taking advantage of the benefits of the advanced materials and construction techniques that have replaced leather in the athletic shoe industry over the last seventy-five years, the investigators hope to restore much of the comfort and fit of these extinct socket designs, while at the same time delivering the improvements that have been delivered by the athletic shoe industry and advances in design and manufacturing over the same period. Lim design is working on a textile based prosthetic socket; however, the approach differs from the investigators': 1) The Lim design is not intended or currently suitable for upper limbs; 2) While a textile design, the Lim design cannot dynamically change in volume through the range of motion and constrains motion similar to any other socket once it has been adjusted; 3) The textile design of the Lim socket is nether breathable nor wicking and is designed to be used with silicone and/or gel liners, hence suffers from the same deficiencies with respect to heat and moisture management as traditional sockets. Lim Innovations and Ossur have publicly stated that they do not intend to pursue further innovations in the upper limb market. These frank admissions make it clear that the development of orphan devices for Veterans, must become the responsibility of the VA, whose goals for serving Veterans are sometimes in contrast with and not limited to the constraints of large and profitable markets. VA in collaboration with small companies can help fill this much needed void for innovation. VA has shown leadership in related domains with the research and design for ultralight wheelchairs, alternative controls for powered wheelchairs, and adaptive sports and recreation equipment, all of which eventually assisted the broader populations of Americans with disabilities. Harness discomfort is just as detrimental to acceptance as poor socket-body interface and can lead to contralateral damage to the axilla. Indeed, one recent study concluded that there was no acceptable level of force at which a body powered prosthesis could be operated pain and fatigue free with a traditional harness. While the conclusions of this study obviously contradict the staying power of the body powered prosthesis and harness system accepted by more than 90 per cent of the roughly half of users who accept a prosthesis at all, it does indicate that there is substantial improvement to be made in harnessing that could significantly improve both acceptance and comfort of the users who have been willing to tolerate the uncomfortable standard of care that has seen slow progress for decades.
Study Objectives and Hypothesis:
Specific Aim 1: Improve and develop the design and systems for fitting an innovative new transradial suspension design based on currently available technology used in athletic shoe construction.
- Design Criteria 1a: Optimize CAD documentation by revising and translating the current Autodesk Fusion 360 design to SolidWorks, aiding customization and improving design for manufacture.
- Design Criteria 1b: Verify that the currently Direct Metal Laser Sintered (DMLS) printed wrist and quick release can be efficiently and effectively CNC machined.
- Design Criteria 1c: Create fixturing and finalize CNC programming for manufacture, including the specification of manufacturing tolerances to ensure proper fit of components.
- Design Criteria 1e: Verify forearm and elbow counter parts-currently printed in Multijet Fusion (MJF)-in Selective Laser Sintering (SLS) or Fused Deposition or Fused Filament (FDM/FFF) Nylon material.
- Design Criteria 1f: Automate adaptation of the design through plugin and API development.
- Design Criteria 1g: Optimize production of 2D textile patterns with, for example, ExactFlat.
- Design Criteria 1h: Design a digital or Brannock-like fitting device for measuring the residual limb and locating bony prominences of the limb to inform the socket design.
- Design Criteria 1i: Design the device to weigh less than 2 pounds in total. The design will address common limitations of current upper-limb prostheses by improving comfort, range of motion, function, and sustained prosthesis use among individuals with transradial amputation.
Specific Aim 2: Verify performance gains for the innovative KSH system that can be delivered to Veterans. The new design is expected to significantly exceed the performance of the standard-of-care prosthesis in quantitative measures.
- Hypothesis 2a (H2a): That the improved KSH will provide a higher tensile static load bearing capacity before failure than the current standard-of-care prosthesis.
- Hypothesis 2b (H2b): That the improved KSH will provide greater tensile loads in a dynamic environment. The KSH system will allow users to perform better on a rowing ergometer 10-minute test before failure than the current standard-of-care prosthesis, as measured using strokes per minute, power in Watts, distance in meters, maximal force, and time before failure.
- Hypothesis 2c (H2c): The improved KSH will provide a greater range of motion in flexion/extension than the current standard-of-care prosthesis.
- Hypothesis 2d (H3d): Participants will require less time for donning/doffing the KSH than their current standard-of-care prosthesis.
Specific Aim 3: Verify functionality of the KSH system through testing with end-users.
- Hypothesis 3a (H3a): Participants will report high usability with setup and operation of the device (>80 on the System Usability Scale (SUS)).
- Hypothesis 3b (H3b): Participants will report significantly higher Socket Comfort Scores (SCS) with the KSH than their current standard-of-care prosthesis.
- Hypothesis 3c (H3c): Lower weight will correlate with greater user satisfaction, and the KSH will be statistically and clinically significantly lighter than participants' current devices.
- Hypothesis 3d (H3d): Participants will report that they would switch to the new design or have an additional prosthesis with the new design.
- Hypothesis 3e (H3e): Participants will report significantly higher Orthotics and Prosthetics User Survey (OPUS) scores with the KSH than their current standard-of-care prosthesis.
Relevance to Veterans: According to the DoD/VA Extremity Amputation Center of Excellence there were about 3,000 Veterans with transradial amputations enrolled for VA Healthcare in FY21, out of about 62,000 Veterans with limb amputations enrolled for VA healthcare. Veterans with arm amputations from Post-911 conflicts number just over 200, and because the total number of Veterans missing arms is demographically small, this very fact has severely limited innovation in the field of prosthetic arms. Those missing at least all five fingers of a hand are among the VA's most significantly disabled Veterans, rated at 80 per cent disabled alone for the loss of a dominant hand. Many arm amputees are eligible for Special Monthly Compensation as well as vehicle and housing modifications, reflecting the degree to which these Veterans' lives are impacted by the impairment. Indeed, even among the civilian population, arm amputation is rare enough to easily meet the FDA's medical orphan criteria of fewer than 200,000 patients, though the FDA's orphan drug law specifically excludes medical devices, and the FDA has a lower device threshold of 8,000 patients, further limiting innovation. The NIH's Genetic and Rare Diseases Information Center (GARD) lists limb absence as a rare birth condition but doesn't mention the same disability acquired by trauma or through other diseases, such as cancer, which is the second most common cause despite the small total number from all causes. While the subject design can be extended to other levels of amputation, this study will focus on transradial, or below elbow amputees. This population represents approximately seventy-five per cent of the VA population of Veterans with arm amputations, a subset that is also much more likely to successfully wear a prosthetic arm. Over 90% of these users choose body powered. The design could be extended to other Veteran populations, including people with lower-limb amputations and other levels of amputation, potentially increasing the benefit by offering the same benefits to those Veterans. By targeting the portion of an orphan population that is already more likely to use the device for which improvement is sought, and by targeting the concerns that are most likely to lead to abandonment, this research stands to increase acceptance and therefore access to activities of daily living, employment and recreation that can improve quality of life for some of the VA's most impaired patients. Success could then also be translated to larger populations with similar needs. The proposed design is intended to address more than half the total population of Veterans with upper limb amputations and could with additional research and development be designed in the future for other levels of amputation, including lower limb and myoelectric upper limb use.
Study design
- Primary purpose
- Other
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- The protocol consists of three phases with iterative design and development process involving input from Veterans with disabilities at various stages. In addition, 5 certified Prosthetists with at least five years of experience working with Veterans with transradial arm amputations will also be recruited to provide guidance and to assist with the design and development of the K-Socket Harness (KSH).
| Arm | Type | Receives |
|---|---|---|
| Verify performance gains for the innovative KSH system that can be delivered to Veterans. The new de | Experimental | Device: K-Socket-HarnessThe investigators will perform several functional tests of the both the KSH system and the standard of care prosthesis: tensile static load bearing capacity before failure, test rowing ergometer 10-minute test before failure measured using strokes per minute, power in Watts, distance in meters, maximal force, and time before failure, range of motion in flexion/extension, and donning/doffing time. |
| Verify functionality of the KSH system through testing with end-users. | Experimental | Device: K-Socket-HarnessThe investigators will use System Usability Scale (SUS) to assess high usability with setup and operation of the device. The investigators will assess Comfort Scores (SCS), evaluate weight and correlate it with user satisfaction. The investigators will report selection outcome between new design and current design. The investigators will asses 1) functional status, (2) health- related quality of life, and (3) satisfaction with services and (4) device scores through the Orthotics and Prosthetics User Survey (OPUS). |
Who may qualify
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (6 listed)
- Unilateral transradial arm amputation
- Possession of a functioning and wearable previously fit prosthetic arm of any type
- Residual limb length of at least 4 inches from the lateral epicondyle to the distal tip
- Residual limb length less than or equal to that allowing a clearance of 1.5 inches from a fitted wrist
- Must have at least 5-years of prosthetic use experience (For Phase 1 \& 2)
Key exclusion criteria (4 listed)
- Current open sores or incisions, Heterotopic ossification (HO), traumatic neuromas, or any other condition preventing the wearing of a prosthetic socket
- Residual limb length less than 4 inches
- Residual limb length greater than that allowing 1.5 inches clearance from a fitted wrist.
- The investigators will make every effort to recruit Veterans. If its found that it is not possible to recruit enough Veterans, the investigators will perform a non-Veteran amendment to this protocol.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| K-Socket-HarnessAlso: KSH SystemA transradial socket and harness design that offers a hybrid polymer and textile-based design derived from advanced athletic shoe technology. The KSH integrated socket, frame, and wrist, the "variable compliance prosthetic socket with breathable matrix," creates a dynamic and secure attachment with a combination of two lacing systems. The lacing systems lengthen and shorten six flexible hinges at the elbow, maintaining a secure attachment throughout the range of motion and accounting for volume changes in the soft tissue of the elbow that would otherwise restrict range of motion or cause the socket to separate from the residual limb. | Device | Verify functionality of the KSH system through testing with end-users., Verify performance gains for the innovative KSH system that can be delivered to Veterans. The new de |
Primary outcome
Static tensile load bearing capacity to reach a 50-pound load on an industrial scale
Time frame: 20 minutes
The investigators will test tensile static load bearing capacity up to a 50 -pound load or to failure. The Veteran will stand safely on an industrial scale with the arm extended at their side and weight will be added to the distal end of the prosthesis until the goal is met or the prosthesis fails. The investigators will perform the task on both the KSH socket and the standard socket.
Elbow range of motion in flexion/extension
Time frame: 30 minutes
The investigators will measure range of motion (in degrees) in flexion/extension with a standard goniometer. The investigators will perform the task on both the KSH socket and the standard socket.
Donning/doffing prosthesis
Time frame: 30 minutes
The investigators will record the time it takes to donn/doff each prosthesis for both the KSH socket and the standard socket.
Power in Watts generated on rowing machine
Time frame: 10 minutes
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test before failure, as measured using power in Watts. The investigators will perform the task on both the KSH socket and the standard socket.
Strokes per 10-minute period
Time frame: 10 minutes
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test before failure, as measured using strokes per minute. The investigators will perform the task on both the KSH socket and the standard socket.
Distance rowed in meters
Time frame: 10 minutes
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test measuring distance in meters before failure or to time expiration. The investigators will perform the task on both the KSH socket and the standard socket.
Maximal force before failure
Time frame: 10 minutes
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test measuring maximal force (Newton) before failure. The investigators will perform the task on both the KSH socket and the standard socket.
Total time before failure
Time frame: 10 minutes
The investigators will test tensile loads in a dynamic environment before failure. The investigators will test the performance on a rowing ergometer 10-minute test recording the time (in minutes and seconds) before failure. The investigators will perform the task on both the KSH socket and the standard socket.
5 secondary outcomes
Usability of prosthesis using the System Usability Score (SUS) on scale from 0-100
Time frame: 15 minutes
Socket Comfort Scores (SCS) on a scale from 0-10
Time frame: 30 minutes
Weight of device in pounds
Time frame: 30 minutes
Participant preference
Time frame: 10 minutes
Orthotics and Prosthetics User Survey (OPUS)
Time frame: 1 hour
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Jul 2026.
- Background: PubMed 33377803Salminger S, Stino H, Pichler LH, Gstoettner C, Sturma A, Mayer JA, Szivak M, Aszmann OC. Current rates of prosthetic usage in upper-limb amputees - have innovations had an impact on device acceptance? Disabil Rehabil. 2022 Jul;44(14):3708-3713. doi: 10.1080/09638288.2020.1866684. Epub 2020 Dec 30.
- Background: PubMed 18090439Biddiss E, Chau T. Upper-limb prosthetics: critical factors in device abandonment. Am J Phys Med Rehabil. 2007 Dec;86(12):977-87. doi: 10.1097/PHM.0b013e3181587f6c.
- Background: PubMed 28621577Hichert M, Vardy AN, Plettenburg D. Fatigue-free operation of most body-powered prostheses not feasible for majority of users with trans-radial deficiency. Prosthet Orthot Int. 2018 Feb;42(1):84-92. doi: 10.1177/0309364617708651. Epub 2017 Jun 16.
- Background: PubMed 14617445Hanspal RS, Fisher K, Nieveen R. Prosthetic socket fit comfort score. Disabil Rehabil. 2003 Nov 18;25(22):1278-80. doi: 10.1080/09638280310001603983.
- Background: PubMed 14727700Heinemann AW, Bode RK, O'Reilly C. Development and measurement properties of the Orthotics and Prosthetics Users' Survey (OPUS): a comprehensive set of clinical outcome instruments. Prosthet Orthot Int. 2003 Dec;27(3):191-206. doi: 10.1080/03093640308726682.
- Background: PubMed 12190225Dillingham TR, Pezzin LE, MacKenzie EJ. Limb amputation and limb deficiency: epidemiology and recent trends in the United States. South Med J. 2002 Aug;95(8):875-83. doi: 10.1097/00007611-200208000-00018.
- Individual participant dataSharing planned: Yes. Any information obtained from this study will be treated as confidential and will be safeguarded in accordance with the HIPAA privacy and security regulations. Research records may be released or disclosed if required by federal law. Records will be coded by assigning a case number and the information linking the case number to the subject's identity will be stored electronically on the VAPHS network. Any protected health information (PHI) stored electronically is in compliance with the HIPAA security rule. Study subjects will not be specifically identified in any publication of research results. Paper source documents of the coded research records will be kept in file cabinets within a locked file room. Any records which contain direct subject identifiers will be stored separately, with a different identification code, in a locked file cabinet within a locked file room. Records will be maintained in accordance with the Veterans Health Administration (VHA) Records Control Schedule.
Related trials for Amputation, Surgical
RecruitingObservational study
Early Postoperative Pain Following a Limb Amputation
Amputation, Surgical, Pain Management
Recruiting
Hemocoll, Avitene, or Bone Wax for Cancellous Bone Bleeding After Single-Ray Amputation
Hemostasis, Surgical Blood Loss
RecruitingPhase 2/3
Human Penile Allotransplantation
Amputation, Wounds and Injuries
Not yet recruitingObservational study
Post-Amputation Stump Infection as a Predictor of Persistent Residual Limb Pain: A Prospective Cohort Study
Residual Limb Pain, Stump Pain
Recruiting
Prevention of PostAmputation Pain With Targeted Muscle Reinnervation
Amputation, Surgical, Phantom Limb Pain
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Rory A Cooper, PhD principal investigator
VA Pittsburgh Healthcare System University Drive Division, Pittsburgh, PA
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing K-Socket-Harness in people with Amputation, Surgical, run by VA Office of Research and Development at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 24 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Elizabeth B Toth, BA ((412) 954-5382, elizabeth.toth2@va.gov), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Static tensile load bearing capacity to reach a 50-pound load on an industrial scale (time frame: 20 minutes). The study lists 8 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05990062, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Jul 2026; AzTrials last refreshed its copy on 6 Nov 2026.