Venus-Vitae Pivotal Study Smart-Align Study

A study testing Venus-Vitae Transcatheter Heart Valve System in people with Aortic Valve Stenosis, run by Venus MedTech (HangZhou) Inc..

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Official record
Search all trials

Trial summary

The purpose is to evaluate the safety, effectiveness and performance of Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
Venus-Vitae Transcatheter Heart Valve System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
150 participants
Where
No sites listed yet
Study dates
31 Oct 2023to 30 Jun 2029
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥ 18 years
  • Patients with the symptoms of severe aortic stenosis
  • Severe aortic stenosis (AS, grade 3+), defined as AVA ≤ 1 cm2 (AVAi ≤ 0.6 cm2/m3) or Vmax ≥ 4.0 m/s or MPG ≥ 40 mmHg determined by echocardiography
  • Patients deemed for cardiac intervention by a heart team
  • Patients of all surgical risk categories can be enrolled in this study, but should follows local medical practices and regulatories.
  • Patients or their legal reprensentatives are willing to participate in the study and provide written informed consent, and agree to follow the follow-up requirements

Who cannot join

  • A subject meeting any of the following criteria shall be excluded:
  • Co-morbidities
  • Previous mechanical or biological aortic valve replacement
  • Untreated mitral, tricuspid or pulmonary valve diseases requiring procedural intervention
  • Acute myocardial infact within 30 days prior to index procedure
  • Untreated clinical significant coronary artery disease requiring revascularization
Show all 22Show fewer
  • Any therapeutic invasive cardiac procedure performed within 30 days (or drug-eluting coronary stent/scaffold implant within 6 months)
  • Sever symptomatic carotid artery stenosis
  • Stroke or TIA within 3 months or Modified Rankin Scale ≥ 4 disability
  • Chronic kidney disease (eGFR<30 mL/min/1.73m2)
  • Haemotologic disorders: Leukopenia (WBC < 3000 cell/mL), anemia (Hgb < 9 g/dL), thrombocytopenia (Plt< 50,000 cell/mL), or any known blood clotting disorder, deemed clinically significant after consultation with Haematooncology specialists
  • Severe right heart dysfunction Anatomical
  • LVEF < 20%
  • Echocardiographic evidence of intracardiac mass, thrombus, or vegetation
  • Inappropriate anatomy for femoral introduction and delivery of study device
  • Native aortic valve geometry and size unfavorable for study device anchoring General
  • Haemodynamics instability requiring inotropic support or intra-aortic balloon pump (IABP) or other hemodynamic support device, or any mechanical heart assistance
  • Known hypersensitivity or contraindication to antiplatelet, antithrombotic medications, or cobalt-chromium leading to be unable to undergo index procedure per physicians' judgement
  • Life expectancy ≤ 1 year due to noncardiac reasons
  • Active infection requiring antibiotic therapy including infective endocarditis
  • Planned relevant concomitant procedure within 30 days post index procedure
  • Pregnant, breastfeeding or intend to become pregnant within 1 year

About this study

Official title: Multicenter Pivotal Study to Evaluate the Treatment of Severe Aortic Valve Stenosis With Next-Generation Venus-Vitae Transcatheter Heart Valve (THV) System

The purpose is to evaluate the safety, effectiveness and performance of Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis.

Read the detailed description

This trial is a prospective, multi-center, non-randomized interventional study to evaluate the safety, effectiveness and performance of the Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis. Clinical visits will be scheduled at screening, pre-discharge, 30 days, 6 months, 12 months and annually thereafter to 5 years.

Being tested
Venus-Vitae Transcatheter Heart Valve System
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Venus-Vitae Transcatheter Heart Valve SystemDevice

    The Venus-Vitae THV is comprised of balloon-expandable and radiopaque cobalt-chromium alloy frame, porcine pericardium tri-leaflet, porcine pericardium inner skirt, polyurethane outer skirt, PTFE assembly sutures, and three radiopaque gold markers (Figure 1). The valve utilizes Venus Endura technology and stored in a non-aqueous condition.

Study groups in NCT05991271
Study groupRoleWhat they receive
procedureExperimentalimplant valve by TAVR
Receives: Device: Venus-Vitae Transcatheter Heart Valve System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The rate of deaths at the one-year follow-up visit post procedure

    All-cause mortality (The rate of deaths at the one-year follow-up visit post procedure)

    Measured: 1 Years

  2. Acceptable Hemodynamic Performance at 30 days

    Acceptable Bio-prosthesis Hemodynamic Performance at 30 days, defined as:

    • Mean gradient < 20mmHg
    • Less than moderate aortic regurgitation (perivalvular and transvalvular)

    Measured: 30 Days

Secondary outcomes (8)
  1. Occurrence of the following adverse events echocardiogram during follow-up

    Occurrence of the following adverse events echocardiogram during follow-up (The rate of follow events during the follow-up)

    • All-cause mortality
    • All stroke
    • Life-threatening bleeding
    • Acute MI
    • Heart failure hospitalizations
    • New permanent pacemaker implantation
    • Major vascular complication
    • Acute kidney injury
    • Aortic valve re-intervention (surgical or transcatheter)
    • Valve thrombosis
    • Structural valve deterioration

    Measured: 5 Years

  2. Technical success is defined as the following

    Technical success (at exit from procedure room) (VARC-3[1]) (The rate of Technical success at the Procedure)

    • Freedom from mortality
    • Successful access, delivery of the device, and retrieval of the delivery system
    • Correct positioning of a single prosthetic heart valve into the proper anatomical location
    • Freedom from surgery or intervention related to the device or a major vascular or access-related, or cardiac structural complication

    Measured: During the Procedure

  3. The rate of device success is defined as the following

    Device success (in-hospital) (VARC-3[1]) (The rate of device success during the in-hospital)

    • Freedom from mortality
    • Freedom from surgery or intervention related to the device or a major vascular or access-related or cardiac structural complication
    • Intended performance of the valve (mean gradient < 20 mmHg, peak velocity <3 m/s, and less than moderate aortic regurgitation)

    Measured: Up to 1 week

  4. The rate of acceptable valve function at pre-discharge by echocardiogram defined as the following:

    Acceptable valve function at pre-discharge by echocardiogram (The rate of follow events during the follow-up)

    • Freedom from moderate or greater patient-prosthesis mismatch (PPM)
    • MPG <20mmHg
    • Freedom from moderate or greater regurgitation (transvalvular and paravalvular)
    • Freedom from reoperation or intervention

    Measured: Up to 1 week

  5. The rate of freedom from severe coronary overlap assessed by post-implant angiogram

    Freedom from severe coronary overlap assessed by post-implant angiogram

    Measured: immediately after the procedure

  6. The rate of freedom from mild or greater commissure misalignment assessed by post-implant angiogram and/or 30-day CT

    Freedom from mild or greater commissure misalignment assessed by post-implant angiogram and/or 30-day CT (post-implant 30-day CT scan is not mandatory for each subjects)

    Measured: 30-Days

  7. The rate of freedom from mild or greater PVL by echocardiogram during follow-up

    Freedom from mild or greater PVL by echocardiogram during follow-up

    Measured: 5 Years

  8. New York Heart Association (NYHA) classification during follow-up

    New York Heart Association (NYHA) classification during follow-up

    Measured: 5 Years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Aug 2023
  2. Study start31 Oct 2023 (estimated)
  3. Primary completion31 Dec 2024 (estimated)
  4. Study completion30 Jun 2029 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
150 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05991271
Sponsor's protocol ID
VTAR-23-03
Status last verified
Aug 2023
First submitted
26 Jun 2023
Last updated
18 Aug 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Venus-Vitae Transcatheter Heart Valve System in people with Aortic Valve Stenosis, run by Venus MedTech (HangZhou) Inc..

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 22 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 18 Aug 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The rate of deaths at the one-year follow-up visit post procedure (time frame: 1 Years). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.