AzTrials
AzTrials

Cone-Beam Computed TomographyNCT06056063

Project Looking-Glass Evaluation

A study testing Halcyon 4.0 in people with Cone-Beam Computed Tomography, run by Abramson Cancer Center at Penn Medicine at 1 site in United States.

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

Pilot study to validate the new design and workflow of Cone-Beam CT imaging for radiation therapy treatment simulation. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cone-Beam Computed Tomography
What is being tested?
Halcyon 4.0
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
27 participants
Where
1 siteUnited States
Study dates
19 Nov 2023to 30 Sep 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subjects will be treated with external beam radiotherapy at the Perelman Center for Advanced Medicine for any of the following malignancies: head-and-neck, thoracic, breast, gastrointestinal, gynecologic, or genitourinary.
  • Age ≥ 18 years
  • Ability to understand the requirements of the study and to give written informed consent, as determined by the treating physician
  • Availability of a complete set of treatment plans, including CT simulation images, target and normal structure contours, and radiation treatment prescriptions

Who cannot join

  • Subjects who are pregnant or have plans for pregnancy during the period of treatment.
  • Any malignancy not stated above.
  • Those unable to be treated on any linear accelerator (whether Truebeam™ or Halcyon™) unit either due to subject anatomy or treatment plan.
  • Those undergoing proton therapy.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Perelman Center for Advanced Medicine

    Philadelphia, Pennsylvania, 19104

Other trials in United States

About this study

Official title: Evaluation of Novel CT Imaging for Simulation on a Linear Accelerator

Pilot study to validate the new design and workflow of Cone-Beam CT imaging for radiation therapy treatment simulation.

Read the detailed description

This study is a prospective, non-randomized imaging evaluation study. A cohort of subjects undergoing standard of care radiation therapy will be selected based on malignancies from six disease sites. The Halcyon 4.0 images acquired in place of standard evaluation CT scans during the course of treatment will be used for target volume delineation and normal structures segmentation. Treatment plans will be recalculated based on the Halcyon 4.0 images from this system and compared to the original treatment plan. Dose differences will be evaluated. Two-tailed t-test will be used to compare the statistical significance of the dosimetric results as well as the volumetric differences among target volume and the volumes of organs at risk.

Being tested
Halcyon 4.0

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Halcyon 4.0Device

    This Halcyon 4.0 is a new imaging hardware recently developed by Varian and approved by the FDA.

Study groups in NCT06056063
Study groupRoleWhat they receive
Evaluate the Halcyon 4.0 obtained CBCT in comparison to a CT SIM for radiotherapy dose planningExperimentalTo evaluate the Halcyon 4.0 as a machine that will obtain CBCT that will be comparable to a CT simulator for radiotherapy treatment planning dose calculation. The novel CBCT images of subjects with malignancies from six disease sites obtained during the course of treatment for evaluation in place of the standard evaluation CBCT will be compared to their initial standard conventional CT simulation images used for treatment planning.
Receives: Device: Halcyon 4.0

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Acceptability of image quality of the novel cone-beam CT imaging system compared to that of standard cone-beam CT imaging and that of conventional fan beam CT imaging used for radiotherapy planning purposes

    Qualitative results (Yes is acceptable/No is not acceptable) will be reported as tabulated data to demonstrate the differences from the standard practice

    Measured: 1 year

  2. Ease of use of the novel cone-beam CT imaging system compared to standard practice

    Ease of use of the novel cone-beam CT imaging system on a scale of 1 (very easy to use, no difficulty) to 5 (unable to use due to difficulty)

    Measured: 1 year

  3. Quantitative comparison of the image quality of the novel cone-beam CT imaging system to that of standard cone-beam CT imaging and that of conventional fan beam CT imaging used for radiotherapy planning purposes

    A scale of Better/Worse/Equal will be used for metrics such as CBCT image artifact, CBCT image quality for OAR contouring, CBCT image quality for GTV contouring, motion artifacts, auto-segmentation ability, electron density similarity

    Measured: 1 year

  4. Statistical significance of quantitative comparison of the image quality of the novel cone-beam CT imaging system and standard practice

    For situations that the quantitative results will be measured, such as the structure volume or predicted electron densities etc., statistical significance will be calculated.

    Measured: 1 year

Secondary outcomes (1)
  1. Evaluation of the suitability and workflow of the novel CBCT images for radiation treatment planning and dose calculation.

    The secondary endpoint is to compare the accuracies of dose and volume calculations to the standard arm using the conventional CT simulation.

    Measured: 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Sep 2023
  2. Study start19 Nov 2023
  3. Primary completion11 Oct 2024
  4. Study completion30 Sep 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
27 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06056063
Sponsor's protocol ID
UPCC 02923
Other IDs
852966
Status last verified
Sep 2025
First submitted
28 Aug 2023
Last updated
15 Sep 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Halcyon 4.0 in people with Cone-Beam Computed Tomography, run by Abramson Cancer Center at Penn Medicine at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 15 Sep 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Acceptability of image quality of the novel cone-beam CT imaging system compared to that of standard cone-beam CT imaging and that of conventional fan beam CT imaging used for radiotherapy planning purposes (time frame: 1 year). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Sep 2025; AzTrials last refreshed its copy on 29 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in