AzTrials
AzTrials

Aortic StenosisNCT06069661

U.S. Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR

A study testing Aortic Stenosis in people with Aortic Stenosis, run by EnCompass Technologies, Inc. at 1 site in United States.

Withdrawn

Withdrawn. The study stopped before anyone enrolled.

Official record
Search all trials

Trial summary

The goal of this clinical trial is to learn about the safety and performance of the F2 device for cerebral embolic protection in participants with symptomatic aortic stenosis undergoing a Transcatheter Aortic Valve replacement procedure. Read more about this study

Who is it for?
Ages 22 years and older
Conditions the study is for
Aortic Stenosis
What is being tested?
Aortic Stenosis
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
0 participants
Where
1 siteUnited States
Study dates
Jun 2024to Jan 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 22 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥ 22 years.
  • The patient meets the established criteria and indications for commercially available TAVR (Edwards/Medtronic) for transfemoral access.
  • Modified Rankin Scale (mRS) 0 or 1 at screening.
  • Montreal Cognitive Assessment (MoCA) score ≥ 26 at screening.
  • The patient is willing and able to comply with protocol-specified follow-up evaluations.
  • 6 The patient or legally authorized representative is able and willing to provide written informed consent.

Who cannot join

  • Subjects are not eligible for the study if any of the following criteria are present:
  • Contraindications to MRI (e.g., subjects with MR unsafe implants including implantable temporary or permanent pacemaker or defibrillator, metal implants in field of view, metallic fragments, clips, or devices in the brain or eye before TAVR procedure, or claustrophobia).
  • Severe peripheral arterial, abdominal aortic, or thoracic aortic disease that precludes delivery sheath vascular access or filter deployment.
  • Patients in whom the aortic arch is heavily calcified, severely atheromatous, or severely tortuous.
  • Ascending aortic diameter > 38 mm or transverse aortic diameter > 27 mm.
  • Evidence of an acute myocardial infarction within 1 month before TAVR.
Show all 26Show fewer
  • Pre-existing prosthetic heart valve or prosthetic ring in any position.
  • Known intracardiac thrombus.
  • Severe allergy or known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel, nitinol, stainless steel alloy, and/or contrast sensitivity that cannot be adequately pre-medicated.
  • History of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated.
  • Patients who refuse blood transfusion.
  • Active peptic ulcer or history of upper gastrointestinal (GI) bleeding within the prior 3 months.
  • Recent (within 6 months) CVA or a TIA.
  • Renal insufficiency (creatinine > 2.5 mg/dL or GFR < 30) and/or renal replacement therapy at the time of screening.
  • Patients with hepatic failure (Child-Pugh class C).
  • Patients with hypercoagulable states that cannot be corrected by additional periprocedural heparin.
  • Patients presenting with cardiogenic shock or requiring vasopressor or inotropic support at the time of the index procedure.
  • Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20%.
  • Life expectancy < 12 months.
  • Currently participating in an investigational drug or another device study that has not completed the initial primary endpoint evaluation (e.g., long term follow-up study/continued access study subjects are able to be included).
  • Subjects who have had treatment with any other investigational device within 30 days prior to study enrollment.
  • Planned surgery or invasive procedure within 30 days following the index procedure (TAVR with F2 Filter).
  • Patients planned to undergo any other cardiac surgical or interventional procedure (e.g., concurrent coronary revascularization) during the TAVR procedure or within 10 days prior to the TAVR procedure. NOTE: Balloon valvuloplasty during TAVR is permitted. Diagnostic cardiac catheterization is permitted within 10 days prior to the TAVR procedure.
  • Patients with known mental or physical illness or known history of substance abuse that may cause non-compliance with the protocol or confound the data interpretation.
  • Females who are pregnant or nursing or plan to become pregnant during their participation in the study. Female subjects of child-bearing potential must have a negative pregnancy test at screening.
  • Any other condition that in the opinion of the investigator, precludes study participation or poses a significant hazard to the patient.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • New York Presbyterian/Columbia University

    New York, New York, 10032

Other trials in United States

About this study

Official title: A Prospective, Single-arm, Multicenter Feasibility Trial to Evaluate the Safety and Performance of the F2 Filter and Delivery System Used for Embolic Protection During Transcatheter Aortic Valve Replacement

The goal of this clinical trial is to learn about the safety and performance of the F2 device for cerebral embolic protection in participants with symptomatic aortic stenosis undergoing a Transcatheter Aortic Valve replacement procedure.

Read the detailed description

The goal of this clinical trial is to learn about the safety and performance of the F2 device for cerebral embolic protection in participants with symptomatic aortic stenosis undergoing a Transcatheter Aortic Valve replacement procedure. The F2 device is inserted via a transfemoral approach and positioned in the aorta to cover and protect the three great cerebral vessels from any debris released during the valve replacement procedure. The F2 device remains in place during the aortic valve replacement procedure. After the valve is placed, the F2 device is removed.

Conditions
Aortic Stenosis
Being tested
Aortic Stenosis
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Aortic StenosisDevice

    F2 Filter and Delivery system to cover the 3 great cerebral vessels

Study groups in NCT06069661
Study groupRoleWhat they receive
Single-ArmExperimentalDevice: F2 Filter and Delivery System
Receives: Device: Aortic Stenosis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Major adverse cardiac and cerebrovascular events (MACCE)

    Major adverse cardiac and cerebrovascular events

    Measured: 30 day

Secondary outcomes (9)
  1. Total new lesion volume

    Total new lesion volume

    Measured: 8-72 hours

  2. Average Individual new Lesion volume

    Average individual new lesion volume

    Measured: 8-72 hours

  3. Number of new Lesions

    Number of Lesions

    Measured: 8-72 hours

  4. Location of new Lesions

    Location of Lesions

    Measured: 8-72 hours

  5. Territory of new Lesions

    Territory of Lesions

    Measured: 8-72 hours

  6. Performance

    Technical success (% of patients with successful device deployment, position and retrieval) and procedure success (% of patients with technical device success and no device-related safety events)

    Measured: Intra-procedure

  7. Modified Rankin Score

    Measures neurological disability on a scale of 0-6 (low score is better outcome)

    Measured: 30 day

  8. National Institute of Health Stroke Scale (NIHSS)

    Measures stroke severity on a scale of 0-42 (low score is better outcome)

    Measured: 30 day

  9. Montreal Cognitive Assessment

    Measures cognitive impairment on a scale of 0-30 (high score is better outcome)

    Measured: 30 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Oct 2023
  2. Study startJun 2024 (estimated)
  3. Primary completionDec 2024 (estimated)
  4. Study completionJan 2025 (estimated)

Why it stopped: moving directly into the Pivotal study

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
0 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06069661
Sponsor's protocol ID
ET02
Status last verified
Feb 2025
First submitted
29 Sep 2023
Last updated
25 Feb 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Aortic Stenosis in people with Aortic Stenosis, run by EnCompass Technologies, Inc. at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 26 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: withdrawn, as of the sponsor's last update on 25 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was withdrawn before enrolling participants, so there are no results.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Major adverse cardiac and cerebrovascular events (MACCE) (time frame: 30 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Feb 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in