Coronary Artery DiseaseGENCOMXNCT06086496
Effectiveness and Safety of Abluminal Biodegradable Polymer Sirolimus-eluting Stent (GENOSS® DES)
An observational study of Coronary Artery Disease and Percutaneous Coronary Intervention, run by Genoss Co., Ltd. at 1 site in South Korea.
Trial summary
In this study, the investigators evaluated the effectiveness and safety of using the GENOSS® DES, which has a biodegradable polymer only on the inner wall of the blood vessel, for patients(all-comers) with coronary artery disease who require percutaneous coronary intervention through stent insertion. Read more about this study
- Who is it for?
- Ages 19 years and older
- Conditions the study is for
- Coronary Artery Disease, Percutaneous Coronary Intervention
- What is being tested?
- GENOSS® DES Sirolimus Eluting Coronary Stent System
- Type of treatment
- Medical device
- How many people
- 1,000 participants
- Where
- 1 siteSouth Korea
- Study dates
- 15 Jul 2022to 31 Dec 2027
- How long will I take part?
- 12 Months
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 19 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Coronary artery disease patients who underwent coronary intervention using the GENOSS® DES
<Inclusion Criteria>
- Adults over 19 years of age
- Patients with typical symptoms or objective evidence of myocardial ischemia and eligible for coronary angioplasty.
- Severe coronary artery stenosis suitable for GENOSS® DES insertion
- Patients who agree to the research protocol and clinical follow-up plan and give written informed consent in the consent form approved by the Institutional Review Board/Ethics Committee of each research institution.
<Exclusion Criteria>
- Test subjects with known hypersensitivity or contraindications to the following drugs or substances: heparin, aspirin, clopidogrel, sirolimus, contrast medium (however, even subjects with hypersensitivity to contrast medium can be controlled by steroids and pheniramine) In this case, registration is possible, but if there is known anaphylaxis, it is excluded)
- Patients who also received other drug-eluting stents
- If you have a disease with a remaining life expectancy of less than 1 year
- Pregnant or lactating women or women who may be pregnant
- Cases in which the patient was admitted to the hospital due to psychogenic shock and the likelihood of survival is medically expected to be low.
- Patients judged by researchers to be unsuitable for research
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
About this study
Official title: Evaluation of Effectiveness and Safety of Abluminal Biodegradable Polymer Sirolimus-eluting Stent in Routine Clinical Practice: A Prospective, Single-arm, Multicenter, Observational Study (The GENCOMX Registry)
In this study, the investigators evaluated the effectiveness and safety of using the GENOSS® DES, which has a biodegradable polymer only on the inner wall of the blood vessel, for patients(all-comers) with coronary artery disease who require percutaneous coronary intervention through stent insertion.
Read the detailed description
This study is a sponsor-initiated clinical trial (SIT) that enrolls patients who underwent percutaneous coronary intervention using the GENOSS® DES drug-eluting stent.
As it is a prospective, multicenter, observational study, the number of subjects is not separately calculated, but the plan is to recruit a total of 1,000 participants at 7 institutions during the study registration period.
- Being tested
- GENOSS® DES Sirolimus Eluting Coronary Stent System
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
GENOSS® DES Sirolimus Eluting Coronary Stent SystemDevice
The GENOSS® DES is L-605 cobalt chromium (CoCr) platform with a strut thickness of 70µm Sirolimus drug with concentration of 1.15µg/mm2 Abluminal biodegradable PLA and PLGA polymers.
| Study group | Role | What they receive |
|---|---|---|
| GENOSS® DES Sirolimus Eluting Coronary Stent System / B03300.20, class [4] | Patients with coronary artery disease who require interventional treatment through stent insertion in real-world practice (all-comer) Receives: Device: GENOSS® DES Sirolimus Eluting Coronary Stent System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Target Lesion Failure (TLF)
The composite end point of cardiac death, TV-MI (target vessel-MI), and TLR (target lesion revascularization)
Measured: at 12 months after the procedure
Secondary outcomes (8)
All deaths
Measured: at 12 months after the procedure
Cardiac death
Measured: at 12 months after the procedure
TV-MI (target vessel-myocardial infarction)
Measured: at 12 months after the procedure
any MI (myocardial infarction)
Measured: at 12 months after the procedure
ID-TVR (ischemia-driven target vessel revascularization)
Measured: at 12 months after the procedure
ID-TLR (ischemia-driven target lesion revascularization)
Measured: at 12 months after the procedure
Stent thrombosis by ARC definition
Measured: at 12 months after the procedure
Procedure success
When the final internal stenosis rate is less than 30% as assessed visually on angiography after the procedure and there is no death, Q-wave myocardial infarction, or urgent revascularization during hospitalization.
Measured: during the hospitalization period (up to 3 days)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Oct 2023
- Study start15 Jul 2022
- Primary completion31 Dec 2027 (estimated)
- Study completion31 Dec 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Genoss Co., Ltd.The sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 1,000 participants (estimated)
- Target duration
- 12 Months
Sponsor and investigators
- Lead sponsor
- Genoss Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06086496
- Sponsor's protocol ID
- 2022AN0320
- Acronym
- GENCOMX
- Status last verified
- Sep 2025
- First submitted
- 4 Oct 2023
- Last updated
- 6 Oct 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: The data set is available from the the corresponding author upon reasonable request.
Study at a glance
From the registry record, last updated by the sponsor on 6 Oct 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Effectiveness and Safety of Abluminal Biodegradable Polymer Sirolimus-eluting Stent in Routine Clinical Practice: A Prospective, Single-arm, Multicenter, Observational Study (The GENCOMX Registry)
- ClinicalTrials.gov ID
- NCT06086496
- Acronym / sponsor ID
- GENCOMX / 2022AN0320
- Study type
- Observational
- Recruitment status
- Enrolling by invitation
- Enrolment
- 1,000 participants (estimated)
- Lead sponsor
- Genoss Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- 15 Jul 2022 (actual)
- Primary completion
- 31 Dec 2027 (estimated)
- Study completion
- 31 Dec 2027 (estimated)
- First posted
- 17 Oct 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
In this study, the investigators evaluated the effectiveness and safety of using the GENOSS® DES, which has a biodegradable polymer only on the inner wall of the blood vessel, for patients(all-comers) with coronary artery disease who require percutaneous coronary intervention through stent insertion.
Detailed description
This study is a sponsor-initiated clinical trial (SIT) that enrolls patients who underwent percutaneous coronary intervention using the GENOSS® DES drug-eluting stent.
As it is a prospective, multicenter, observational study, the number of subjects is not separately calculated, but the plan is to recruit a total of 1,000 participants at 7 institutions during the study registration period.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Target follow-up
- 12 Months
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| GENOSS® DES Sirolimus Eluting Coronary Stent System / B03300.20, class [4] | – | Device: GENOSS® DES Sirolimus Eluting Coronary Stent SystemPatients with coronary artery disease who require interventional treatment through stent insertion in real-world practice (all-comer) |
Who may qualify
- Ages
- 19 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Coronary artery disease patients who underwent coronary intervention using the GENOSS® DES
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| GENOSS® DES Sirolimus Eluting Coronary Stent SystemThe GENOSS® DES is L-605 cobalt chromium (CoCr) platform with a strut thickness of 70µm Sirolimus drug with concentration of 1.15µg/mm2 Abluminal biodegradable PLA and PLGA polymers. | Device | GENOSS® DES Sirolimus Eluting Coronary Stent System / B03300.20, class [4] |
Primary outcome
Target Lesion Failure (TLF)
Time frame: at 12 months after the procedure
The composite end point of cardiac death, TV-MI (target vessel-MI), and TLR (target lesion revascularization)
8 secondary outcomes
All deaths
Time frame: at 12 months after the procedure
Cardiac death
Time frame: at 12 months after the procedure
TV-MI (target vessel-myocardial infarction)
Time frame: at 12 months after the procedure
any MI (myocardial infarction)
Time frame: at 12 months after the procedure
ID-TVR (ischemia-driven target vessel revascularization)
Time frame: at 12 months after the procedure
ID-TLR (ischemia-driven target lesion revascularization)
Time frame: at 12 months after the procedure
Stent thrombosis by ARC definition
Time frame: at 12 months after the procedure
Procedure success
Time frame: during the hospitalization period (up to 3 days)
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Oct 2025.
- Individual participant dataSharing planned: No. The data set is available from the the corresponding author upon reasonable request.
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Coronary Artery Disease and Percutaneous Coronary Intervention, run by Genoss Co., Ltd. at 1 site in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: enrolling by invitation, as of the sponsor's last update on 6 Oct 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Target Lesion Failure (TLF) (time frame: at 12 months after the procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Oct 2025.