Coronary Artery DiseaseNCT06087575
Early Feasibility Study of the Supira System in Patients Undergoing HRPCI
A study testing Supira System in people with Coronary Artery Disease and High-risk Percutaneous Coronary Intervention, run by Supira Medical at 4 sites in United States.
Trial summary
The objective of this study is to assess the feasibility and safety of the Supira System in providing temporary cardiovascular hemodynamic support in patients undergoing HRPCI. The clinical data may be used to support subsequent regulatory applications and further evaluation of the Supira System. Read more about this study
- Who is it for?
- Ages 18 to 90 years
- Conditions the study is for
- Coronary Artery Disease, High-risk Percutaneous Coronary Intervention, Interventional Cardiology
- What is being tested?
- Supira System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 15 participants
- Where
- 4 sitesUnited States
- Study dates
- 4 Oct 2024to 17 Apr 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 90 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Subjects will be eligible for inclusion in this study if all of the following criteria apply:
- Age ≥18 and ≤90 years
- Subject is hemodynamically stable and will undergo elective or urgent (not emergent) HRPCI, where hemodynamic support is needed, as determined by the institutional heart team
- Informed consent granted by the patient or legally authorized representative
Subjects who meet any one of the following criteria will be excluded from study participation:
- Cardiogenic shock or acutely decompensated pre-existing chronic heart failure
- Note: Cardiogenic shock is defined as: systemic hypotension (systolic blood pressure (BP) <90 mmHg or the need for inotropes/pressors to maintain a systolic BP >90 mmHg) plus one of the following: any requirement for inotropes/pressors prior to arrival at the catheterization laboratory, clinical evidence of end-organ hypoperfusion or use of intra-aortic balloon pump (IABP), or any other circulatory support device.
- Stroke within 6 months of the index procedure, or any prior stroke with permanent neurologic deficit
- Evidence of left ventricular thrombus as assessed by Transthoracic Echocardiogram (TTE)
- Aortic valvular disease or regurgitation categorized as moderate or greater (≥2+ on a 4-grade scale as assessed on TTE)
- Aortic stenosis categorized as moderate or greater (gradient >20 mmHg or valve area <1.5 cm^2 as assessed on TTE)
- Previous aortic valve replacement or reconstruction
- Ascending or descending aortic dissection or aortic aneurysm >4.5 cm
- Aortic and iliofemoral anatomical conditions that preclude safe delivery and placement of the investigational device
- Presence of decompensated liver disease; severe liver dysfunction (Child class C)
- Ongoing renal replacement therapy with dialysis
- Infection of the proposed procedural access site or systemic active infection requiring ongoing antibiotic therapy
- Heparin-induced thrombocytopenia, current or any prior occurrences
- Known hypersensitivity to intravenous contrast agents that cannot be adequately pre-medicated or known hypersensitivity to heparin, aspirin, adenosine diphosphate (ADP) receptor inhibitors, or nitinol
- Known or suspected coagulopathy or abnormal coagulation parameters (defined as platelet count ≤ 100,000/mm³ or spontaneous International Normalized Ratio (INR) ≥1.5 or known fibrinogen ≤1.5 g/L)
- Any condition or scheduled surgery that will require discontinuation of antiplatelet and/or anticoagulant therapy within 90 days of the index procedure
- Planned coronary intervention within 30 days post index procedure
- Breastfeeding or pregnant
- Currently participating in active follow-up phase of another clinical study of an investigational drug or device
- Active COVID-related infection or prior COVID-19 diagnosis with sequelae that could confound endpoint assessments
- Other medical, social, or psychological problems that, in the opinion of the Investigator, compromises the subject's ability to provide written informed consent and/or to comply with study procedures
- Considered to be part of a vulnerable population (defined as individuals with mental disability, impoverished persons, homeless persons, nomads, refugees and those permanently incapable of giving informed consent; vulnerable populations also may include members of a group with a hierarchical structure such as university students, subordinate hospital and laboratory personnel, employees of the Sponsor, members of the armed forces and persons kept in detention)
Trial locations and contacts
4 sites in 1 country.
United States4 sites
Piedmont Heart Institute Cardiovascular Research
Atlanta, Georgia, 30309
Mount Sinai
New York, New York, 10029
University of California Davis (UC Davis) Medical Center
Sacramento, California, 95817
Montefiore Medical Center Cardiology Research
The Bronx, New York, 10467
About this study
Official title: Early Feasibility Study of the Supira System in Patients Undergoing High-Risk Percutaneous Coronary Intervention (HRPCI) - The SUPPORT I Trial
The objective of this study is to assess the feasibility and safety of the Supira System in providing temporary cardiovascular hemodynamic support in patients undergoing HRPCI. The clinical data may be used to support subsequent regulatory applications and further evaluation of the Supira System.
Read the detailed description
The Supira System is a temporary (≤ 4 hours) ventricular support device indicated for use during elective or urgent HRPCI performed in hemodynamically stable patients with severe coronary artery disease when a heart team, including a cardiac surgeon, has determined HRPCI is the appropriate therapeutic option.
- Conditions
- Coronary Artery Disease, High-risk Percutaneous Coronary Intervention, Interventional Cardiology
- Being tested
- Supira System
- Keywords
- left ventricular assist device (LVAD), peripheral mechanical circulatory support (MCS), Supira System
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Supira SystemDevice
The Supira System is a minimally invasive, miniaturized percutaneous ventricular assist device (pVAD) system that is intended to provide temporary (≤4 hours) hemodynamic support to patients undergoing a HRPCI procedure. The Catheter is inserted percutaneously via the femoral artery, across the aortic valve, and into the left ventricle under fluoroscopic guidance, with a portion remaining in the ascending aorta. The left ventricle is unloaded by pumping blood from the ventricle into the ascending aorta and systemic circulation.
| Study group | Role | What they receive |
|---|---|---|
| Supira System | Experimental | Ventricular support indicated for use during elective or urgent high-risk percutaneous coronary interventions. Receives: Device: Supira System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Feasibility: Successful initiation and maintenance of hemodynamic support
Successful initiation and maintenance of hemodynamic support without severe hypotension throughout the index procedure. Sustained hypotension is defined as sustained mean arterial pressure (MAP) < 60 mmHg requiring inotropic/pressor medications or alternative mechanical circulatory support.
Measured: From device delivery through removal (up to 4 hours)
Safety: Rate of composite major device-related adverse events (MDRAEs), from device insertion through device removal (inclusive of Supira procedure-related SAEs).
MDRAEs are defined as any serious adverse events that are adjudicated by the Clinical Events Committee (CEC) as definitely or probably related to the Supira System.
Measured: From device delivery through device removal (up to 4 hours)
Secondary outcomes (5)
Technical Success
Rate of technical success, defined as completion of the entire Supira System procedure, including delivery, operation without device malfunction, and successful removal of the Catheter
Measured: From device delivery through device removal (up to 4 hours)
Procedural Success
Rate of procedural success, defined as the rate of technical success without procedural SAEs.
Measured: From device delivery through device removal (up to 4 hours)
Rate of composite MDRAEs from device removal through hospital discharge or 72 hours post-procedure, whichever occurs first.
Measured: From device removal through hospital discharge or 72 hours post-procedure (whichever occurs first) through 30 days post device removal.
Rate of composite MDRAEs from hospital discharge or 72 hours post-procedure (whichever occurs first) through 30 days post device removal.
Measured: From hospital discharge or 72 hours post-procedure (whichever occurs first) through 30 days post device removal.
Rate of composite MDRAEs from 30 days to 90 days post device removal.
Measured: From 30 days to 90 days post device removal.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted18 Oct 2023
- Study start4 Oct 2024
- Primary completion25 Feb 2025
- Study completion17 Apr 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- The study is a prospective, non-randomized, single-arm, multicenter, feasibility study
- Masking
- None (open label)
- Enrolment
- 15 participants (actual)
Sponsor and investigators
- Lead sponsor
- Supira Medical
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06087575
- Sponsor's protocol ID
- CP-10003
- Status last verified
- Feb 2026
- First submitted
- 5 Oct 2023
- Last updated
- 9 Feb 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Kandzari DE, Mignatti A, Kini A, Wong G, Singh G, Latib A, Costa R, Campos CM, Abizaid A. Clinical Experience With a Novel Percutaneous LV Assist Device in High-Risk PCI: Primary Results From the SUPPORT I Study. Circ Cardiovasc Interv. 2026 May 5:e016010. doi: 10.1161/CIRCINTERVENTIONS.125.016010. Online ahead of print.
PubMed 42083862
Study at a glance
From the registry record, last updated by the sponsor on 9 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Early Feasibility Study of the Supira System in Patients Undergoing High-Risk Percutaneous Coronary Intervention (HRPCI) - The SUPPORT I Trial
- ClinicalTrials.gov ID
- NCT06087575
- Acronym / sponsor ID
- CP-10003
- Conditions
- Coronary Artery Disease, High-risk Percutaneous Coronary Intervention, Interventional Cardiology
- Keywords
- left ventricular assist device (LVAD), peripheral mechanical circulatory support (MCS), Supira System
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 15 participants (actual)
- Lead sponsor
- Supira MedicalIndustry (pharma, biotech, devices)
- Study start
- 4 Oct 2024 (actual)
- Primary completion
- 25 Feb 2025 (actual)
- Study completion
- 17 Apr 2025 (actual)
- First posted
- 18 Oct 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The objective of this study is to assess the feasibility and safety of the Supira System in providing temporary cardiovascular hemodynamic support in patients undergoing HRPCI. The clinical data may be used to support subsequent regulatory applications and further evaluation of the Supira System.
Detailed description
The Supira System is a temporary (≤ 4 hours) ventricular support device indicated for use during elective or urgent HRPCI performed in hemodynamically stable patients with severe coronary artery disease when a heart team, including a cardiac surgeon, has determined HRPCI is the appropriate therapeutic option.
Study design
- Primary purpose
- Device feasibility
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- The study is a prospective, non-randomized, single-arm, multicenter, feasibility study
| Arm | Type | Receives |
|---|---|---|
| Supira System | Experimental | Device: Supira SystemVentricular support indicated for use during elective or urgent high-risk percutaneous coronary interventions. |
Who may qualify
- Ages
- 18 to 90 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Supira SystemThe Supira System is a minimally invasive, miniaturized percutaneous ventricular assist device (pVAD) system that is intended to provide temporary (≤4 hours) hemodynamic support to patients undergoing a HRPCI procedure. The Catheter is inserted percutaneously via the femoral artery, across the aortic valve, and into the left ventricle under fluoroscopic guidance, with a portion remaining in the ascending aorta. The left ventricle is unloaded by pumping blood from the ventricle into the ascending aorta and systemic circulation. | Device | Supira System |
Primary outcome
Feasibility: Successful initiation and maintenance of hemodynamic support
Time frame: From device delivery through removal (up to 4 hours)
Successful initiation and maintenance of hemodynamic support without severe hypotension throughout the index procedure. Sustained hypotension is defined as sustained mean arterial pressure (MAP) < 60 mmHg requiring inotropic/pressor medications or alternative mechanical circulatory support.
Safety: Rate of composite major device-related adverse events (MDRAEs), from device insertion through device removal (inclusive of Supira procedure-related SAEs).
Time frame: From device delivery through device removal (up to 4 hours)
MDRAEs are defined as any serious adverse events that are adjudicated by the Clinical Events Committee (CEC) as definitely or probably related to the Supira System.
5 secondary outcomes
Technical Success
Time frame: From device delivery through device removal (up to 4 hours)
Procedural Success
Time frame: From device delivery through device removal (up to 4 hours)
Rate of composite MDRAEs from device removal through hospital discharge or 72 hours post-procedure, whichever occurs first.
Time frame: From device removal through hospital discharge or 72 hours post-procedure (whichever occurs first) through 30 days post device removal.
Rate of composite MDRAEs from hospital discharge or 72 hours post-procedure (whichever occurs first) through 30 days post device removal.
Time frame: From hospital discharge or 72 hours post-procedure (whichever occurs first) through 30 days post device removal.
Rate of composite MDRAEs from 30 days to 90 days post device removal.
Time frame: From 30 days to 90 days post device removal.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Feb 2026.
- Derived from this study: PubMed 42083862Kandzari DE, Mignatti A, Kini A, Wong G, Singh G, Latib A, Costa R, Campos CM, Abizaid A. Clinical Experience With a Novel Percutaneous LV Assist Device in High-Risk PCI: Primary Results From the SUPPORT I Study. Circ Cardiovasc Interv. 2026 May 5:e016010. doi: 10.1161/CIRCINTERVENTIONS.125.016010. Online ahead of print.
- Individual participant dataSharing planned: No
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
4 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Supira System in people with Coronary Artery Disease and High-risk Percutaneous Coronary Intervention, run by Supira Medical at 4 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Feasibility: Successful initiation and maintenance of hemodynamic support (time frame: From device delivery through removal (up to 4 hours)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06087575, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Feb 2026.