Sleep Apnea, ObstructiveNCT06097949
AcuPebble to Remotely Monitor Patients With OSA on CPAP Therapy
An observational study of Sleep Apnea, Obstructive, run by Royal Free Hospital NHS Foundation Trust at 1 site in United Kingdom.
Trial summary
Obstructive sleep apnoea (OSA) is a breathing problem that happens when you sleep. It is treated by a machine called continuous positive airway pressure (CPAP) therapy. The goal of this observational trial is to test how well a new wearable device can detect ongoing OSA in patients undergoing treatment with CPAP. Read more about this study
- Who is it for?
- Ages 18 to 80 years
- Conditions the study is for
- Sleep Apnea, Obstructive
- What is being tested?
- AcuPebble SA100
- Type of treatment
- Medical device
- How many people
- 25 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 7 Oct 2022to Feb 2024
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients with an existing diagnosis of obstructive sleep apnoea who have been established on continuous positive airway pressure (CPAP) therapy and are deemed compliant with therapy.
Who may be able to join
- Patients with an initial diagnosis of moderate/severe OSA (AHI ≥ 15events/hr made on full polysomnography, cardiorespiratory-polygraphy or other validated home sleep study) with no evidence of hypoventilation
- Patients who have been established on CPAP therapy for > 3months
- Patients who are deemed compliant on CPAP therapy (average use ≥ 4 hours/night for ≥ 70% of the last 28 days)
Who cannot join
- Age <18
- Subjects not fluent in English, or who have special communication needs
- Known allergy to adhesive dressing
- Subjects with physical or mental impairments who would not be able to use the device and technology on their own
- Subjects with implantable devices
- Subjects with stridor
- Subjects unable to give consent
- Subjects on non-invasive ventilation (NIV) or bi-level positive airway pressure (BIPAP)
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site, 1 recruiting
- Recruiting
Academic Respiratory Department Royal Free Hospital NHS Foundation Trust
London
Swapna Mandal, 02077940500 ext. 23359, swapnamandal@nhs.net
Amar Shah, 02077940500 ext. 23359, amar.shah5@nhs.net
About this study
Official title: The Use of a Novel Wearable Medical Device (AcuPebble SA100) to Remotely Monitor Patients With Obstructive Sleep Apnoea (OSA) on Continuous Positive Airway Pressure Therapy (CPAP)
Obstructive sleep apnoea (OSA) is a breathing problem that happens when you sleep. It is treated by a machine called continuous positive airway pressure (CPAP) therapy.
The goal of this observational trial is to test how well a new wearable device can detect ongoing OSA in patients undergoing treatment with CPAP. The main questions it aims to answer are:
Read more
- Does the new wearable device detect OSA in patients undergoing treatment with CPAP as well as gold standard sleep studies?
- Does the new wearable device detect OSA in patients undergoing treatment with CPAP more accurately than the CPAP machine can itself.
Participants will be asked to wear the following two devices while using their CPAP machine for 2 nights:
- AcuPebble SA100 (the new wearable device). This device is the size of a 2-pence coin and sits on the front of the neck and attaches via some double sided sticky tape. It is connected via bluetooth to a mobile phone application (app).
- A multi-channel sleep study, which is the gold standard way of performing sleep studies.
Researchers will then compare how much OSA is left in participants, comparing the values from the new device, gold standard sleep study and the CPAP machine itself.
Read the detailed description
Obstructive sleep apnoea (OSA) affects almost one billion people globally and can lead to numerous health consequences including ischaemic heart disease, hypertension, stroke and arrhythmias. It also has a profound impact on patient's quality of life and has a high economic burden on society. Continuous positive airway pressure (CPAP) therapy is globally accepted gold-standard treatment, virtually eliminating OSA (by normalising the apnoea-hypopnoea index (AHI)), thus improving quality of life, decreasing sleepiness and reducing medical sequelae. A high residual AHI may still be present despite adequate CPAP usage in some patients. This patient population will suffer with on-going / worsening somnolence, sleep apnoea symptoms and potentially increased cardiovascular risk, which will no doubt reduce their adherence thus increasing their residual AHI, perpetuating a viscous cycle.
Currently CPAP machines can store airflow and pressure data, displaying residual events and compliance indices. However, algorithms between devices vary and there are no standards on how to use the data, and there is mixed data surrounding residual event accuracy. A review by the American Thoracic Society concluded that while CPAP usage can be reliably determined from tracking systems, residual events (residual AHI) and mask leak data are not easy to interpret and differ depending on manufactures. Some studies have found that this is especially the case in relation to detecting hypopnoeic events. Therefore, a more accurate and simple system is needed to accurately determine usage and residual events, that is: standardised, reliable and independent of machine manufacturer. Overnight oximetry is used by some Trusts as a surrogate marker of residual events. However, studies that have validated overnight oximetry against polysomnography (gold standard) have found the specificity and sensitivity decrease with decreasing severity of disease. Therefore this is not a practical or reliable way to monitor patients remotely.
Therefore we aim to assess whether we can accurately measure the residual AHI with a simple, accurate, novel wearable device in patients undergoing CPAP therapy. This will enable us to accurately assess treatment effect and highlight patients who require more intensive / change in their therapy.
AcuPebble SA100 is a CE marked novel wearable device developed by Acurable Ltd which has already been validated as an automated diagnostic tool for OSA with a high positive (96%) and high negative (995) predictive value when compared to a gold standard sleep study. This is currently in clinical use. We intend to assess whether AcuPebble SA100 can also be used to accurately detect the residual AHI in patients with OSA on CPAP therapy.
Patients in this study will be asked to wear both AcuPebble SA100 and a gold standard multi-channel sleep study simultaneously, alongside using CPAP therapy for two consecutive nights. We will then compare the residual AHI from AcuPebble SA100 with gold standard, as well as comparing the accuracy of the CPAP machine AHI with gold standard. This will also enable us to detect whether AcuPebble SA100 is more accurate that the CPAP machine.
We will also assess the usability of AcuPebble SA100 in this population.
- Conditions
- Sleep Apnea, Obstructive
- Being tested
- AcuPebble SA100
- Keywords
- OSA, CPAP, Wearable technology
- Medical subject headings
- Sleep Apnea, Obstructive
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
AcuPebble SA100Device
This device is not being used as an interventional device but simply a monitoring tool on patients already on CPAP therapy. The device is being used within the scope of it's intended purpose as a medical device to diagnose OSA.
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy of the residual AHI measured by AcuPebble SA100
Our primary outcome will be to measure the residual AHI with AcuPebble SA100 and compare the accuracy of this measurement against a gold standard multi-channel sleep study. The residual AHI is a measurement that quantifies the amount of sleep disordered breathing that is still present despite treatment.
Measured: 6 months
Secondary outcomes (3)
Comparing the residual AHI measured by AcuPebble SA100 and the CPAP machine
To measure the residual AHI with AcuPebble SA100 and compare it to the measurement dervied from the continuous positive airway pressure (CPAP) machine. The residual AHI is a measurement that quantifies the amount of sleep disordered breathing that is still present despite treatment.
Measured: 6 months
Accuracy of the effective AHI measured by AcuPebble SA100
To measure the total night-time AHI (effective AHI) using AcuPebble SA100 and compare this measurement to a gold standard multi-channel sleep study. The residual AHI is a measurement that quantifies the amount of sleep disordered breathing that is still present despite treatment.
Measured: 6 months
Measure the acceptability of AcuPebble SA100
To measure how comfortable AcuPebble SA100 is to wear for people while they use their CPAP machine.
Measured: 6 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted24 Oct 2023
- Study start7 Oct 2022
- Primary completionFeb 2024 (estimated)
- Study completionFeb 2024 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Sleep Apnea, ObstructiveStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 25 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Royal Free Hospital NHS Foundation Trust
- Sponsor type
- University, hospital or other
- Collaborators
- Acurable Ltd.
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06097949
- Sponsor's protocol ID
- 311874
- Status last verified
- Oct 2023
- First submitted
- 19 Sep 2023
- Last updated
- 24 Oct 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: No plan to share individual participant data
Study at a glance
From the registry record, last updated by the sponsor on 24 Oct 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Use of a Novel Wearable Medical Device (AcuPebble SA100) to Remotely Monitor Patients With Obstructive Sleep Apnoea (OSA) on Continuous Positive Airway Pressure Therapy (CPAP)
- ClinicalTrials.gov ID
- NCT06097949
- Acronym / sponsor ID
- 311874
- Conditions
- Sleep Apnea, Obstructive
- Keywords
- OSA, CPAP, Wearable technology
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 25 participants (estimated)
- Lead sponsor
- Royal Free Hospital NHS Foundation TrustUniversity, hospital or other
- Collaborators
- Acurable Ltd.
- Study start
- 7 Oct 2022 (actual)
- Primary completion
- Feb 2024 (estimated)
- Study completion
- Feb 2024 (estimated)
- First posted
- 24 Oct 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Obstructive sleep apnoea (OSA) is a breathing problem that happens when you sleep. It is treated by a machine called continuous positive airway pressure (CPAP) therapy.
The goal of this observational trial is to test how well a new wearable device can detect ongoing OSA in patients undergoing treatment with CPAP. The main questions it aims to answer are:
- Does the new wearable device detect OSA in patients undergoing treatment with CPAP as well as gold standard sleep studies?
- Does the new wearable device detect OSA in patients undergoing treatment with CPAP more accurately than the CPAP machine can itself.
Participants will be asked to wear the following two devices while using their CPAP machine for 2 nights:
- AcuPebble SA100 (the new wearable device). This device is the size of a 2-pence coin and sits on the front of the neck and attaches via some double sided sticky tape. It is connected via bluetooth to a mobile phone application (app).
- A multi-channel sleep study, which is the gold standard way of performing sleep studies.
Researchers will then compare how much OSA is left in participants, comparing the values from the new device, gold standard sleep study and the CPAP machine itself.
Detailed description
Obstructive sleep apnoea (OSA) affects almost one billion people globally and can lead to numerous health consequences including ischaemic heart disease, hypertension, stroke and arrhythmias. It also has a profound impact on patient's quality of life and has a high economic burden on society. Continuous positive airway pressure (CPAP) therapy is globally accepted gold-standard treatment, virtually eliminating OSA (by normalising the apnoea-hypopnoea index (AHI)), thus improving quality of life, decreasing sleepiness and reducing medical sequelae. A high residual AHI may still be present despite adequate CPAP usage in some patients. This patient population will suffer with on-going / worsening somnolence, sleep apnoea symptoms and potentially increased cardiovascular risk, which will no doubt reduce their adherence thus increasing their residual AHI, perpetuating a viscous cycle.
Currently CPAP machines can store airflow and pressure data, displaying residual events and compliance indices. However, algorithms between devices vary and there are no standards on how to use the data, and there is mixed data surrounding residual event accuracy. A review by the American Thoracic Society concluded that while CPAP usage can be reliably determined from tracking systems, residual events (residual AHI) and mask leak data are not easy to interpret and differ depending on manufactures. Some studies have found that this is especially the case in relation to detecting hypopnoeic events. Therefore, a more accurate and simple system is needed to accurately determine usage and residual events, that is: standardised, reliable and independent of machine manufacturer. Overnight oximetry is used by some Trusts as a surrogate marker of residual events. However, studies that have validated overnight oximetry against polysomnography (gold standard) have found the specificity and sensitivity decrease with decreasing severity of disease. Therefore this is not a practical or reliable way to monitor patients remotely.
Therefore we aim to assess whether we can accurately measure the residual AHI with a simple, accurate, novel wearable device in patients undergoing CPAP therapy. This will enable us to accurately assess treatment effect and highlight patients who require more intensive / change in their therapy.
AcuPebble SA100 is a CE marked novel wearable device developed by Acurable Ltd which has already been validated as an automated diagnostic tool for OSA with a high positive (96%) and high negative (995) predictive value when compared to a gold standard sleep study. This is currently in clinical use. We intend to assess whether AcuPebble SA100 can also be used to accurately detect the residual AHI in patients with OSA on CPAP therapy.
Patients in this study will be asked to wear both AcuPebble SA100 and a gold standard multi-channel sleep study simultaneously, alongside using CPAP therapy for two consecutive nights. We will then compare the residual AHI from AcuPebble SA100 with gold standard, as well as comparing the accuracy of the CPAP machine AHI with gold standard. This will also enable us to detect whether AcuPebble SA100 is more accurate that the CPAP machine.
We will also assess the usability of AcuPebble SA100 in this population.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients with an existing diagnosis of obstructive sleep apnoea who have been established on continuous positive airway pressure (CPAP) therapy and are deemed compliant with therapy.
Key inclusion criteria (3 listed)
- Patients with an initial diagnosis of moderate/severe OSA (AHI ≥ 15events/hr made on full polysomnography, cardiorespiratory-polygraphy or other validated home sleep study) with no evidence of hypoventilation
- Patients who have been established on CPAP therapy for > 3months
- Patients who are deemed compliant on CPAP therapy (average use ≥ 4 hours/night for ≥ 70% of the last 28 days)
Key exclusion criteria (8 listed)
- Age <18
- Subjects not fluent in English, or who have special communication needs
- Known allergy to adhesive dressing
- Subjects with physical or mental impairments who would not be able to use the device and technology on their own
- Subjects with implantable devices
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| AcuPebble SA100This device is not being used as an interventional device but simply a monitoring tool on patients already on CPAP therapy. The device is being used within the scope of it's intended purpose as a medical device to diagnose OSA. | Device | – |
Primary outcome
Accuracy of the residual AHI measured by AcuPebble SA100
Time frame: 6 months
Our primary outcome will be to measure the residual AHI with AcuPebble SA100 and compare the accuracy of this measurement against a gold standard multi-channel sleep study. The residual AHI is a measurement that quantifies the amount of sleep disordered breathing that is still present despite treatment.
3 secondary outcomes
Comparing the residual AHI measured by AcuPebble SA100 and the CPAP machine
Time frame: 6 months
Accuracy of the effective AHI measured by AcuPebble SA100
Time frame: 6 months
Measure the acceptability of AcuPebble SA100
Time frame: 6 months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 24 Oct 2023.
- Individual participant dataSharing planned: No. No plan to share individual participant data
Related trials for Sleep Apnea, Obstructive
RecruitingObservational study
Development and Validation of a Multimodal Deep Learning Model Using Peripheral Oxygen Saturation and Ballistocardiography Signals for Predicting Apnea-Hypopnea Index in Obstructive Sleep Apnea
Obstructive Sleep Apnea
RecruitingPhase 3
A Study to Learn About the Monthly Dosing Study Medicine Called Berobenatide in Adults With Breathing Problems During Sleep and Overweight or Obesity Who Do Not Use a Breathing Machine (PAP) (VESPER-OSA 2)
Apnea, Sleep Disorders
Not yet recruitingPhase 2
Supplemental Oxygen for Sleep-Disordered Breathing in Adults With Chronic Opioid Use.
Sleep-disordered Breathing, Chronic Opioid Use
Recruiting
Nightly Wearable Monitoring During Home-Based Submental Electrical Stimulation for Obstructive Sleep Apnea
Obstructive Sleep Apnea
RecruitingPhase 1/2
DRonabinol Treatment of OSA
Obstructive Sleep Apnea
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Sleep Apnea, Obstructive, run by Royal Free Hospital NHS Foundation Trust at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 24 Oct 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Swapna Mandal, PhD (0207 794 0500 ext. 23359, swapnamandal@nhs.net), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy of the residual AHI measured by AcuPebble SA100 (time frame: 6 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Oct 2023.