Corneal DiseaseNCT06101017
Developing a Nationwide Registry to Track Longitudinal Clinical Outcomes of Corneal Surgery and Disease
An observational study of Corneal Disease and Endothelial Corneal Dystrophy, run by Nitin Vaswani at 1 site in United States.
Trial summary
The goal is to develop a nationwide registry to track longitudinal clinical outcomes of and store imaging data related to numerous corneal conditions. There are two main objectives including the establishment of the first nationwide corneal transplant registry in the United States to include information related to the… Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Corneal Disease, Endothelial Corneal Dystrophy, Corneal Transplant Failure
- What is being tested?
- Optical Coherence Tomography
- How many people
- 19 participants
- Where
- 1 siteUnited States
- Study dates
- 12 Oct 2023to 15 Aug 2024
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: Adults (18+) with corneal disease and have received and OCT or Pentacam scan
Who may be able to join
- All subjects with corneal disease or undergoing corneal transplantation (either penetrating keratoplasty, endothelial keratoplasty [including DSAEK and DMEK], or anterior lamellar keratoplasty are eligible to be included in this study. Imaging studies performed pre-operatively, up until 1 year prior to surgery will be collected. Studies may include the following:
- OCT
- Corneal topography
- Specular biomicroscopy
- In vivo confocal biomicroscopy
Who cannot join
- Any criteria that does not meet the inclusion criteria above.
Trial locations and contacts
1 site in 1 country.
United States1 site
Keratoplasty Alliance International
Baltimore, Maryland, 21210
About this study
The goal is to develop a nationwide registry to track longitudinal clinical outcomes of and store imaging data related to numerous corneal conditions. There are two main objectives including the establishment of the first nationwide corneal transplant registry in the United States to include information related to the donor tissue, recipient, surgical procedure, and long-term clinical outcomes. Ultimately, this prospective data collection will allow us to determine prognostic factors for successful corneal transplantation and create an algorithm to guide clinical practice based on real world outcomes. The second objective is to collect and create a database of historical, de-identified optical coherence topography (OCT) and corneal topography images to ultimately develop artificial intelligence (AI) based diagnostic and prognostic algorithms for corneal disease and surgery.
Read the detailed description
Background. Overview of ocular conditions and global statistics Corneal disease is the fifth leading cause of blindness in the world, and approximately 4.5 million individuals have moderate to severe vision impairment secondary to loss of corneal clarity. Compared to other leading causes of blindness, corneal disease primarily affects a younger population and therefore has a greater disability-adjusted life years. Only 1 in 70 individuals with corneal blindness ultimately undergoes corneal transplantation due to a number of issues including socioeconomic and political factors. As a result, the number of keratoplasty procedures completed in the U.S. per annum is about 50,000.
Tracking Long-Term Outcomes After Corneal Transplantation In the United States, there is currently no registry or database tracking donor or recipient longitudinal outcomes after corneal transplantation. Other organ transplants including kidney, liver, heart, lung, and pancreas have an established registry , despite corneal transplants being one of the most common transplantations in the US. Australia is one of the few countries that has an established corneal graft registry since 1985, which has provided invaluable insight to determine positive and negative prognostic factors affecting corneal graft survival. In order to obtain best subject outcomes, clinical practice should ideally be tailored to selecting the best type of surgery (i.e. penetrating keratoplasty [PKP], endothelial keratoplasty [EK], anterior lamellar keratoplasty [ALK], or artificial cornea) for each individual patient, based on real world outcomes data.
Developing and utilizing artificial intelligence for corneal disease Machine learning, which plays an ever-growing role in developing artificial intelligence systems for medical applications, is a powerful means of handling very large data sets. A variety of algorithms can incorporate many values more efficiently and accurately than humans. Imaging studies are particularly rich, making them well-suited for machine learning.
An accurate AI/ML-enabled algorithm assessment of various imaging studies could improve precision over physical exams, improving patient outcomes by earlier and more accurate detection of abnormalities and better prediction of future outcomes. Additionally, AI/ML-enabled remote collection of patient data presents substantial potential benefits for patients, providers, and the broader health system to monitor disease, outcomes of surgery or treatment. With home- or community-based monitoring, healthy patients can save time and money traveling frequently to the clinic. For those where issues are detected, potential ocular conditions or post-surgical complications can be identified earlier before they become more severe and require intervention or surgery, which improves both patient outcomes and saves health system resources.
Objectives. Primary: To establish the first nationwide corneal registry in the United States to include information related to the disease state, information on donor tissue, recipient data, surgical procedure, and long-term clinical outcomes. Ultimately, this prospective data collection will allow us to determine prognostic factors for successful corneal transplantation and create an algorithm to guide clinical practice based on real world outcomes.
Secondary: To collect and create a database of de-identified imaging studies (including but not limited to optical coherence topography (OCT), in vivo confocal biomicroscopy, specular biomicroscopy, and corneal topography) to ultimately develop artificial intelligence (AI) based diagnostic and prognostic algorithms for corneal disease prevalence, progression and surgery outcomes.
Study Design. Design Prospective and observational.
Study Size The initial study subject recruitment will be piloted at a variety of US centers. All eligible subjects will be recruited and consented subjects will be enrolled during the initial phase of the study.
Data Collection US based corneal surgeons will obtain corneal images pre- and post- corneal transplantation. These de-identified images, along with the clinical information (donor and recipient characteristics, surgical information, and longitudinal outcomes afterwards) will be entered into the registry.
Data Elements for Corneal Graft Registry For the subjects undergoing corneal transplantation, the following elements will be collected and entered into a secure, electronic database. The imaging data source for this study are copies of corneal topography OCT, specular biomicroscopy and in vivo confocal biomicroscopy images produced during routine clinical care. The registry will receive copies of images in any format, including electronic data transfers and CDs. OCT images from different providers and care sites may vary in quality and detail. The abstraction process will map data to a single cohesive data schema.
Data sources All OCT and corneal topography images are de-identified with no subject health information. Only the raw images will be collected for analysis, and OCT images will be compiled with an aim to create an online registry.
Data collection and storage OCT images will be submitted by healthcare providers through a secure, encrypted, imaging request platform with personnel follow-up as needed. Imaging documentation is uploaded to the study's servers and de-identified of all subject data and protected health information (PHI).
Data abstraction Study staff with expertise in assessing OCT images will review all images submitted to detect patterns. These patterns will eventually be used to train AI/ML algorithms for the collection of measurement data.
Data security This study will comply with Health Insurance Portability and Accountability Act (HIPAA) security standards. In addition, the study team has a comprehensive set of security policies, including risk management strategies, incident response protocols, access controls, encryption standards, and study staff training to safeguard all subject images submitted.
Proposed Algorithm Development. Description of proposed Machine Learning method The algorithm has the opportunity to be the most versatile of any automated OCT image classifier and data collector. With enough data, it also can be the most accurate. The algorithm will be trained and optimized using a variety of OCT data from this study.
Data Management. Retention of images Images and documents pertaining to the study will be retained for the length of time required by relevant national or local health authorities, whichever is longer. After that period of time, the documents may be destroyed, subject to local regulations.
Data quality assurance policies The study team ensures the accuracy of data abstracted from OCT images through a range of measures leveraging both technology and human expertise. The image collection platform is designed to flag irregularities and low confidence images using conservative thresholds.
The study team undergoes a training program and must pass rigorous data quality testing before assuming full imaging screening responsibilities. All images are screened by a minimum of two reviewers, and difficult scenarios that are not described in standard procedures are escalated to a senior team lead, per policy. Procedures to document, review, and learn from escalations create feedback loops that improve operational effectiveness and reduce human error.
The study team will maintain logs of all data transformations and perform regular internal data quality audits. The data quality will be continuously monitored and analyzed throughout the submission and review process.
Access to Registry. Role-Based Access Control (RBAC) RBAC will be implemented to define different levels of access based on the user's role. Roles will be well-defined and correspond to specific responsibilities and permissions.
Authentication Strong authentication mechanisms, including two-factor authentication (2FA) will be in place to ensure that only authorized users can access the imaging registry. An authorization workflow where user access requests are reviewed and approved by study personnel will be utilized before access is granted. Study personnel will regularly review and manage user accounts, ensuring that only active users with legitimate access needs have accounts in the registry.
Access Granting / Revocation Access rights and permissions to users will be shared based on roles and responsibilities and the least privilege necessary will be granted for users to perform their tasks. Revoking access rights will be streamlined if users change roles or no longer require access. The study team will implement logging mechanisms to record user activities and access attempts. The study team will review logs to detect and investigate any suspicious or unauthorized activities.
Upon request, auditors from certain regulatory institutions (i.e., CMS, FDA, etc.) or other third-party institutions may be granted temporary access to the registry for auditing purposes.
Incident Reporting Security incidents or breaches related to unauthorized access will be dealt with promptly to mitigate the impact of security incidents and prevent recurrence.
Withdrawal of Imaging Data The Principal Investigator or IRB has the right to remove and imaging data for medical, safety, or administrative reasons at any time. Appropriate procedures will be followed to ensure the safe withdrawal of each image from the study.
Image De-identification.
To ensure the secure and ethical handling of OCT data, a comprehensive image de-identification process will be implemented. This process aims to systematically remove or alter identifiable information from each image and its associated metadata while preserving clinical and research value of the images. The following steps outline the key aspects of this de-identification process:
Removing direct identifiers
- All direct identifiers used for the purpose of individual identification, such as subject names, medical record and accession numbers, and dates of birth, will be thoroughly searched for and removed from each image's pixel data.
- Concurrently, these direct identifiers will also be sought out and removed from the image metadata, except for the medical record number, which will be irreversibly transformed via a cryptographic hashing function.
Pixel-level Anonymization
● If required, specific image regions containing identifiable features, such as facial details or unique markings will undergo either masking or blurring. Such regions lacking diagnostic features will be masked, while those with diagnostic features will be subject to blurring.
Quality Control
- Rigorous quality checks will be executed to ensure that the anonymization process does not compromise the clinical value of the images.
- Trained professionals will review a subset of de-identified images to verify that critical diagnostic features are preserved accurately.
Encryption
- Both the original and de-identified images will be encrypted to ensure their security during storage and transmission.
- All data will be stored in a secure environment with controlled access, adhering to regulatory requirements and industry best practices.
Documentation
- A detailed record of the de-identification process will be maintained, including a comprehensive account of the steps undertaken, personnel involved, and any challenges encountered.
- This document serves as an essential audit trail, offering transparency and aiding in demonstrating compliance with data protection regulations.
- Conditions
- Corneal Disease, Endothelial Corneal Dystrophy, Corneal Transplant Failure, Corneal Transplant Rejection
- Being tested
- Optical Coherence Tomography
- Medical subject headings
- Corneal Diseases, Corneal endothelial dystrophy type 2
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Optical Coherence TomographyDiagnostic test
Non-invasive imaging test that use light waves to take cross-section pictures of the eye.
What is being measured
The primary outcome is the main question the study is designed to answer.
Corneal thickness measurement from OCT images
Measurements of individual corneal layers including the epithelium, Bowman's layer, stroma, Descemet's membrane, and endothelium. Overall corneal thickness from anterior to posterior surface.
Measured: 1 year
Reflectivity measurement from OCT images
Reflectivity profile within different layers of the cornea, including signal-to-noise ratio
Measured: 1 year
Segmentation measurement from OCT images
Identify boundaries of various corneal or retinal layers
Measured: 1 year
Secondary outcomes (5)
Corneal curvature measurement from Pentacam images
Measure two main radii of curvature, one for the anterior (front) surface and one for the posterior (back) surface
Measured: 1 year
Corneal diameter measurement from Pentacam images
The horizontal width of the cornea, also known as the corneal horizontal visible iris diameter (HVID) and will be measured in millimeters.
Measured: 1 year
Corneal volume measurement from Pentacam images
The three-dimensional space occupied by the cornea
Measured: 1 year
Corneal cross-section identification from Pentacam images
Two-dimensional representation of the cornea's internal structure as seen from a side view.
Measured: 1 year
Corneal densitometry measurement from Pentacam images
Measurement used to assess the transparency or opacity of the cornea.
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted25 Oct 2023
- Study start12 Oct 2023
- Primary completion15 Aug 2024
- Study completion15 Aug 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Corneal DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 19 participants (actual)
Sponsor and investigators
- Lead sponsor
- Nitin Vaswani
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Nitin Vaswani, Keratoplasty Alliance International
- Investigators
- Priya M Mathews, MD, Principal investigator, Keratoplasty Alliance InternationalNitin G Vaswani, MD, Principal investigator, Keratoplasty Alliance International
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06101017
- Sponsor's protocol ID
- MS.0823.001
- Status last verified
- Feb 2026
- First submitted
- 17 Oct 2023
- Last updated
- 19 Feb 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 19 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Developing a Nationwide Registry to Track Longitudinal Clinical Outcomes of Corneal Surgery and Disease
- ClinicalTrials.gov ID
- NCT06101017
- Acronym / sponsor ID
- MS.0823.001
- Conditions
- Corneal Disease, Endothelial Corneal Dystrophy, Corneal Transplant Failure, Corneal Transplant Rejection
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 19 participants (actual)
- Lead sponsor
- Nitin VaswaniUniversity, hospital or other
- Study start
- 12 Oct 2023 (actual)
- Primary completion
- 15 Aug 2024 (actual)
- Study completion
- 15 Aug 2024 (actual)
- First posted
- 25 Oct 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal is to develop a nationwide registry to track longitudinal clinical outcomes of and store imaging data related to numerous corneal conditions. There are two main objectives including the establishment of the first nationwide corneal transplant registry in the United States to include information related to the donor tissue, recipient, surgical procedure, and long-term clinical outcomes. Ultimately, this prospective data collection will allow us to determine prognostic factors for successful corneal transplantation and create an algorithm to guide clinical practice based on real world outcomes. The second objective is to collect and create a database of historical, de-identified optical coherence topography (OCT) and corneal topography images to ultimately develop artificial intelligence (AI) based diagnostic and prognostic algorithms for corneal disease and surgery.
Detailed description
Background. Overview of ocular conditions and global statistics Corneal disease is the fifth leading cause of blindness in the world, and approximately 4.5 million individuals have moderate to severe vision impairment secondary to loss of corneal clarity. Compared to other leading causes of blindness, corneal disease primarily affects a younger population and therefore has a greater disability-adjusted life years. Only 1 in 70 individuals with corneal blindness ultimately undergoes corneal transplantation due to a number of issues including socioeconomic and political factors. As a result, the number of keratoplasty procedures completed in the U.S. per annum is about 50,000.
Tracking Long-Term Outcomes After Corneal Transplantation In the United States, there is currently no registry or database tracking donor or recipient longitudinal outcomes after corneal transplantation. Other organ transplants including kidney, liver, heart, lung, and pancreas have an established registry , despite corneal transplants being one of the most common transplantations in the US. Australia is one of the few countries that has an established corneal graft registry since 1985, which has provided invaluable insight to determine positive and negative prognostic factors affecting corneal graft survival. In order to obtain best subject outcomes, clinical practice should ideally be tailored to selecting the best type of surgery (i.e. penetrating keratoplasty [PKP], endothelial keratoplasty [EK], anterior lamellar keratoplasty [ALK], or artificial cornea) for each individual patient, based on real world outcomes data.
Developing and utilizing artificial intelligence for corneal disease Machine learning, which plays an ever-growing role in developing artificial intelligence systems for medical applications, is a powerful means of handling very large data sets. A variety of algorithms can incorporate many values more efficiently and accurately than humans. Imaging studies are particularly rich, making them well-suited for machine learning.
An accurate AI/ML-enabled algorithm assessment of various imaging studies could improve precision over physical exams, improving patient outcomes by earlier and more accurate detection of abnormalities and better prediction of future outcomes. Additionally, AI/ML-enabled remote collection of patient data presents substantial potential benefits for patients, providers, and the broader health system to monitor disease, outcomes of surgery or treatment. With home- or community-based monitoring, healthy patients can save time and money traveling frequently to the clinic. For those where issues are detected, potential ocular conditions or post-surgical complications can be identified earlier before they become more severe and require intervention or surgery, which improves both patient outcomes and saves health system resources.
Objectives. Primary: To establish the first nationwide corneal registry in the United States to include information related to the disease state, information on donor tissue, recipient data, surgical procedure, and long-term clinical outcomes. Ultimately, this prospective data collection will allow us to determine prognostic factors for successful corneal transplantation and create an algorithm to guide clinical practice based on real world outcomes.
Secondary: To collect and create a database of de-identified imaging studies (including but not limited to optical coherence topography (OCT), in vivo confocal biomicroscopy, specular biomicroscopy, and corneal topography) to ultimately develop artificial intelligence (AI) based diagnostic and prognostic algorithms for corneal disease prevalence, progression and surgery outcomes.
Study Design. Design Prospective and observational.
Study Size The initial study subject recruitment will be piloted at a variety of US centers. All eligible subjects will be recruited and consented subjects will be enrolled during the initial phase of the study.
Data Collection US based corneal surgeons will obtain corneal images pre- and post- corneal transplantation. These de-identified images, along with the clinical information (donor and recipient characteristics, surgical information, and longitudinal outcomes afterwards) will be entered into the registry.
Data Elements for Corneal Graft Registry For the subjects undergoing corneal transplantation, the following elements will be collected and entered into a secure, electronic database. The imaging data source for this study are copies of corneal topography OCT, specular biomicroscopy and in vivo confocal biomicroscopy images produced during routine clinical care. The registry will receive copies of images in any format, including electronic data transfers and CDs. OCT images from different providers and care sites may vary in quality and detail. The abstraction process will map data to a single cohesive data schema.
Data sources All OCT and corneal topography images are de-identified with no subject health information. Only the raw images will be collected for analysis, and OCT images will be compiled with an aim to create an online registry.
Data collection and storage OCT images will be submitted by healthcare providers through a secure, encrypted, imaging request platform with personnel follow-up as needed. Imaging documentation is uploaded to the study's servers and de-identified of all subject data and protected health information (PHI).
Data abstraction Study staff with expertise in assessing OCT images will review all images submitted to detect patterns. These patterns will eventually be used to train AI/ML algorithms for the collection of measurement data.
Data security This study will comply with Health Insurance Portability and Accountability Act (HIPAA) security standards. In addition, the study team has a comprehensive set of security policies, including risk management strategies, incident response protocols, access controls, encryption standards, and study staff training to safeguard all subject images submitted.
Proposed Algorithm Development. Description of proposed Machine Learning method The algorithm has the opportunity to be the most versatile of any automated OCT image classifier and data collector. With enough data, it also can be the most accurate. The algorithm will be trained and optimized using a variety of OCT data from this study.
Data Management. Retention of images Images and documents pertaining to the study will be retained for the length of time required by relevant national or local health authorities, whichever is longer. After that period of time, the documents may be destroyed, subject to local regulations.
Data quality assurance policies The study team ensures the accuracy of data abstracted from OCT images through a range of measures leveraging both technology and human expertise. The image collection platform is designed to flag irregularities and low confidence images using conservative thresholds.
The study team undergoes a training program and must pass rigorous data quality testing before assuming full imaging screening responsibilities. All images are screened by a minimum of two reviewers, and difficult scenarios that are not described in standard procedures are escalated to a senior team lead, per policy. Procedures to document, review, and learn from escalations create feedback loops that improve operational effectiveness and reduce human error.
The study team will maintain logs of all data transformations and perform regular internal data quality audits. The data quality will be continuously monitored and analyzed throughout the submission and review process.
Access to Registry. Role-Based Access Control (RBAC) RBAC will be implemented to define different levels of access based on the user's role. Roles will be well-defined and correspond to specific responsibilities and permissions.
Authentication Strong authentication mechanisms, including two-factor authentication (2FA) will be in place to ensure that only authorized users can access the imaging registry. An authorization workflow where user access requests are reviewed and approved by study personnel will be utilized before access is granted. Study personnel will regularly review and manage user accounts, ensuring that only active users with legitimate access needs have accounts in the registry.
Access Granting / Revocation Access rights and permissions to users will be shared based on roles and responsibilities and the least privilege necessary will be granted for users to perform their tasks. Revoking access rights will be streamlined if users change roles or no longer require access. The study team will implement logging mechanisms to record user activities and access attempts. The study team will review logs to detect and investigate any suspicious or unauthorized activities.
Upon request, auditors from certain regulatory institutions (i.e., CMS, FDA, etc.) or other third-party institutions may be granted temporary access to the registry for auditing purposes.
Incident Reporting Security incidents or breaches related to unauthorized access will be dealt with promptly to mitigate the impact of security incidents and prevent recurrence.
Withdrawal of Imaging Data The Principal Investigator or IRB has the right to remove and imaging data for medical, safety, or administrative reasons at any time. Appropriate procedures will be followed to ensure the safe withdrawal of each image from the study.
Image De-identification.
To ensure the secure and ethical handling of OCT data, a comprehensive image de-identification process will be implemented. This process aims to systematically remove or alter identifiable information from each image and its associated metadata while preserving clinical and research value of the images. The following steps outline the key aspects of this de-identification process:
Removing direct identifiers
- All direct identifiers used for the purpose of individual identification, such as subject names, medical record and accession numbers, and dates of birth, will be thoroughly searched for and removed from each image's pixel data.
- Concurrently, these direct identifiers will also be sought out and removed from the image metadata, except for the medical record number, which will be irreversibly transformed via a cryptographic hashing function.
Pixel-level Anonymization
● If required, specific image regions containing identifiable features, such as facial details or unique markings will undergo either masking or blurring. Such regions lacking diagnostic features will be masked, while those with diagnostic features will be subject to blurring.
Quality Control
- Rigorous quality checks will be executed to ensure that the anonymization process does not compromise the clinical value of the images.
- Trained professionals will review a subset of de-identified images to verify that critical diagnostic features are preserved accurately.
Encryption
- Both the original and de-identified images will be encrypted to ensure their security during storage and transmission.
- All data will be stored in a secure environment with controlled access, adhering to regulatory requirements and industry best practices.
Documentation
- A detailed record of the de-identification process will be maintained, including a comprehensive account of the steps undertaken, personnel involved, and any challenges encountered.
- This document serves as an essential audit trail, offering transparency and aiding in demonstrating compliance with data protection regulations.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Adults (18+) with corneal disease and have received and OCT or Pentacam scan
Key inclusion criteria (5 listed)
- All subjects with corneal disease or undergoing corneal transplantation (either penetrating keratoplasty, endothelial keratoplasty [including DSAEK and DMEK], or anterior lamellar keratoplasty are eligible to be included in this study. Imaging studies performed pre-operatively, up until 1 year prior to surgery will be collected. Studies may include the following:
- OCT
- Corneal topography
- Specular biomicroscopy
- In vivo confocal biomicroscopy
Key exclusion criteria (1 listed)
- Any criteria that does not meet the inclusion criteria above.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Optical Coherence TomographyNon-invasive imaging test that use light waves to take cross-section pictures of the eye. | Diagnostic test | – |
Primary outcome
Corneal thickness measurement from OCT images
Time frame: 1 year
Measurements of individual corneal layers including the epithelium, Bowman's layer, stroma, Descemet's membrane, and endothelium. Overall corneal thickness from anterior to posterior surface.
Reflectivity measurement from OCT images
Time frame: 1 year
Reflectivity profile within different layers of the cornea, including signal-to-noise ratio
Segmentation measurement from OCT images
Time frame: 1 year
Identify boundaries of various corneal or retinal layers
5 secondary outcomes
Corneal curvature measurement from Pentacam images
Time frame: 1 year
Corneal diameter measurement from Pentacam images
Time frame: 1 year
Corneal volume measurement from Pentacam images
Time frame: 1 year
Corneal cross-section identification from Pentacam images
Time frame: 1 year
Corneal densitometry measurement from Pentacam images
Time frame: 1 year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Feb 2026.
- Individual participant dataSharing planned: No
Related trials for Corneal Disease
Active, not recruitingPhase 3
Descemet Endothelial Thickness Comparison Trial II
Fuchs, Fuchs Dystrophy
RecruitingObservational study
National Ophthalmic Genotyping and Phenotyping Network (eyeGENE (Registered Trademark)), Stage 3 - Expansion of DNA and Data Repositories for Rare Inherited Ophthalmic Diseases
Inherited Ophthalmic Diseases, Hypopigmentation Disorder
RecruitingObservational study
Validation of Interleukins and Other Cytokines Together With OCT Imaging for Rapid Infectious Keratitis Assessment
Keratitis Bacterial, Keratitis Fungal
Not yet recruiting
A Single-Center Clinical Study Evaluating the Efficacy and Safety of Allogeneic Natural Killer (NK) Cell Transplantation for Mooren's Ulcer
Cornea Disease
Recruiting
Evaluation of a New Laser Refractive Vision Correction Using the TENEO™ 317 Model 2
Hyperopia and Myopia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Priya M Mathews, MD principal investigator
Keratoplasty Alliance International
Nitin G Vaswani, MD principal investigator
Keratoplasty Alliance International
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Corneal Disease and Endothelial Corneal Dystrophy, run by Nitin Vaswani at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Corneal thickness measurement from OCT images (time frame: 1 year). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Feb 2026.