Comparison of Pulse Oximetry (SpO2) With Different Oximeters and Arterial Saturation (SaO2): Oxygap2 Study

An observational study of Respiratory Failure and Hypoxemia, run by Laval University at 3 sites in Canada.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

The oximeter is used to monitor intensive care patients undergoing oxygen therapy. It indicates pulsed oxygen saturation (SpO2), a reflection of arterial oxygen saturation (SaO2) which enables detection of hypoxemia and hyperoxia, both deleterious state. Read more about this study

Who is it for?
Ages 0 to 100 years
Conditions the study is for
Respiratory Failure, Hypoxemia, Hyperoxemia
What is being tested?
SpO2 and SaO2 comparison
Type of treatment
Medical device
How many people
200 participants
Where
3 sitesCanada
Study dates
20 Jun 2024to 30 Dec 2026
Phase
Observational

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 0 to 100 years
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: All patient in ICU with arterial catheter already installed will be consider

Who may be able to join

  • ≥ 18 years old (adult population) -
  • Patients admitted to the Intensive Care Unit
  • Artery catheter already installed
  • Pediatric population
  • Below 18 years old
  • Patients admitted to the Intensive Care Unit
  • Artery catheter already installed

Who cannot join

  • No or poor signal with the usual pulse oximeter/based on clinician judgment
  • High dose of vasopressors or inotropes (epinephrine or norepinephrine ˃ 1mcg/kg/min), shock state (lactates above 3 mmoles/L)
  • Pigmented nails or nail polish
  • Methemoglobinemia history
  • Hemoglobin below 80 g/L
  • Patient in isolation (multi-resistant bacteria, C-Difficile, SARS-COV-2…)
  • Prone position, Extra Corporel Membrane Oxygenator

Trial locations and contacts

3 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Canada3 sites, 3 recruiting
  • CHUM

    Montreal, Quebec, H2X0A9

    Emmanuel Charbonney, 514-890-8000, emmanuel.charbonney@umontreal.ca

    Recruiting
  • CHU Ste-Justine

    Montreal, Quebec, H3T 1C5

    Philippe Jouvet, philippe.jouvet.med@ssss.gouv.qc.ca

    Michael Sauthier

    Not yet recruiting
  • Institut Universitaire de Cardiologie et de Pneumologie de Québec

    Québec, Quebec, G1V 4G5

    Francois Lellouche, francois.lellouche@criucpq.ulaval.ca

    Not yet recruiting

Other trials in Canada

About this study

The oximeter is used to monitor intensive care patients undergoing oxygen therapy. It indicates pulsed oxygen saturation (SpO2), a reflection of arterial oxygen saturation (SaO2) which enables detection of hypoxemia and hyperoxia, both deleterious state. Current SpO2 recommendations aim to reduce both risk of hypoxemia and hyperoxia. SpO2 is considered the 5th vital sign.

Current recommendations for SpO2 targets do not consider the variability of oximeters used in clinical practice. This variability and lack of specification represent an obstacle to an optimal practice of oxygen therapy.

Thus, this study aims to compare the SpO2 values of different oximeters (General Electric-GE, Medtronic, Masimo and Nonin) used in clinical practice with the SaO2 reference value obtained by an arterial gas in order to specify the precision and the systematic biases of the oximeters studied. This data will also make it possible to refine the recommendations concerning optimal oxygenation

Being tested
SpO2 and SaO2 comparison
Medical subject headings
Respiratory Insufficiency, Hypoxia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • SpO2 and SaO2 comparisonDevice

    Several pulse oximeter will be place on patient find few minutes before arterial blood gases. During an arterial blood sample, all SpO2 will be recorded

Study groups in NCT06102499
Study groupRoleWhat they receive
Pediatric populationPediatric population < 18 years old (estimated 100 patients)
Receives: Device: SpO2 and SaO2 comparison
Adult populationAdult population >or= 18 years old (estimated 100 patients)
Receives: Device: SpO2 and SaO2 comparison

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference between GE oximeter SpO2 value and the SaO2 value on arterial blood gases

    Difference between GE oximeter SpO2 and the SaO2 value

    Measured: During procedure (arterial blood gas sample collection)

  2. Difference between Nellcor oximeter SpO2 value and the SaO2 value on arterial blood gases

    Difference between Nellcor oximeter SpO2 and the SaO2 value

    Measured: During procedure (arterial blood gassample collection)

  3. Difference between Masimo oximeter SpO2 value and the SaO2 value on arterial blood gases

    Difference between Masimo oximeter SpO2 and the SaO2 value

    Measured: During procedure (arterial blood gas sample collection)

  4. Difference between Nonin oximeter SpO2 value and the SaO2 value on arterial blood gases

    Difference between Nonin oximeter SpO2 and the SaO2 value

    Measured: During procedure (arterial blood gas sample collection)

Secondary outcomes (2)
  1. Overestimation and underestimation of SaO2

    Percent of pairs with overestimation and underestimation of SaO2 for each oximeter.

    Measured: During procedure (arterial blood gas sample collection)

  2. Hypoxemia detection

    Ability to detect hypoxemia (SpO2 below 90% and PaO2 < 60 mmHg)

    Measured: During procedure (arterial blood gas sample collection)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Oct 2023
  2. Study start20 Jun 2024
  3. Primary completion30 Jun 2026 (estimated)
  4. Study completion30 Dec 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06102499
Sponsor's protocol ID
22373
Acronym
Oxygap 2
Status last verified
Aug 2025
First submitted
6 Oct 2023
Last updated
28 Aug 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in