AzTrials
AzTrials

Cervical Spine FusionNCT06117267

Navigation Image Accuracy Test in Cervical Spine Surgery Using Anatase Spine Surgery Navigation System

A study testing Anatase Spine Surgery Navigation System in people with Cervical Spine Fusion, run by China Medical University Hospital.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The "Anatase" Spine Surgery Navigation System used in this study has obtained market approval in Taiwan(MOHW-MD-No.006663) and the United States (510(k) Numbers: K180523 and K220348). Read more about this study

Who is it for?
Ages 18 to 70 years
Conditions the study is for
Cervical Spine Fusion
What is being tested?
Anatase Spine Surgery Navigation System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
8 participants
Where
No sites listed yet
Study dates
Nov 2023to 30 Sep 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 70 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥18 years and ≤70 years
  • Patients who need to undergo posterior cervical pedicle screw placement surgery
  • The subject is willing to provide preoperative CT images and to use the navigation system during surgery for the verification of navigation image accuracy.
  • Subjects are willing and able to comply with the procedures and requirements of this clinical trial.
  • Subjects are able to understand and willing to sign the informed consent form.

Who cannot join

  • Creutzfeldt-Jakob disease
  • Known allergy to stainless steel
  • Immunocompromised such as but not limited to Acquired Immunodeficiency Syndrome (AIDS), HIV infection, Severe Combined Immunodeficiency Syndrome, Thymic Hypoplasia
  • Pregnant women
  • Have a systematic or local infection, which may increase study risk
  • Hereditary or acquired hemorrhagic diathesis or coagulation factor deficiency
Show all 12Show fewer
  • Use of anticoagulants
  • Osteoporosis
  • Be on uncontrolled diabetes mellitus.
  • Immunologically suppressed, or has received systemic steroids, excluding nasal steroids, at any dose daily for > 1 month within last 12 months.
  • Previous history of cervical spine surgery
  • Other medical conditions, as judged by a physician, may affect the physiological status for surgery.

Trial locations and contacts

No sites are listed yet.

About this study

Official title: A Single-arm, Single-center Clinical Study to Verify the Navigation Image Accuracy in Cervical Spine Surgery Using Anatase Spine Surgery Navigation System

The "Anatase" Spine Surgery Navigation System used in this study has obtained market approval in Taiwan(MOHW-MD-No.006663) and the United States (510(k) Numbers: K180523 and K220348).

The "Anatase" Spine Surgery Navigation System, also known as an Image Guide System, is indicated for precise positioning of surgical instruments or spinal implants, such as pedicle screw placement, during general spinal surgery. The system uses wireless optical tracking technology to track the position of instruments in relation to the surgical anatomy and register to the relative position in preoperative 3D CT imagery.

The aim of the study is to verify the accuracy of "Anatase" Spine Surgery Navigation System in Image-guided Cervical Spine Surgery. This trial will involve 8 subjects using the approved "Anatase" Spine Surgery Navigation System to collect images before screw implantation, and verify the accuracy of navigation images in cervical spine surgery.

Read the detailed description

The "Anatase" Spine Surgery Navigation System, is composed of an Optical Tracker, Computer, No-Touch Reader and Dynamic Reference Frame (DRF). The Optical Tracker is a position sensor, it tracks the position of instruments with DRF by infrared light, allowing the instrument and vertebra to be positioned. The Computer is a touch screen panel PC running the proprietary spine NAVI software that guides the surgical procedure and display the results of the operation and computation. A No-Touch Reader, which attached on the Optical Tracker, is a no-touch sensor to identify instruments. It's a unique design and identification technology allows the instrument to be wirelessly identified, reducing the risk and time required to set up the instrument type. The system can track the position of patient's vertebra and instruments by mounting the DRF on patient's vertebra and instruments.

The "Anatase" Spine Surgery Navigation System is indicated for precise positioning of surgical instruments or spinal implants during general spinal surgery. The system helps to guide surgeons with real-time image and provides preoperative planning and intraoperative control.

Being tested
Anatase Spine Surgery Navigation System
Keywords
Spine Surgery Navigation System
Medical subject headings
Klippel-Feil Syndrome

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Anatase Spine Surgery Navigation SystemDevice

    Collect images with the probe touching the target position before screw implantation

Study groups in NCT06117267
Study groupRoleWhat they receive
Anatase Spine Surgery Navigation SystemExperimentalUsing the navigation system during surgery
Receives: Device: Anatase Spine Surgery Navigation System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference between the actual and virtual (navigation system) distance of the probe.

    The assessor will measure the distance (mm) of the probe between the actual and virtual (navigation system) images.

    Measured: during the surgery

  2. Difference between the actual and virtual (navigation system) angle of the probe.

    The assessor will measure the angle (°) of the probe between the actual and virtual (navigation system) images.

    Measured: during the surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Nov 2023
  2. Study startNov 2023 (estimated)
  3. Primary completion30 Sep 2024 (estimated)
  4. Study completion30 Sep 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
8 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06117267
Sponsor's protocol ID
CMUH112-REC1-144
Status last verified
Nov 2023
First submitted
27 Oct 2023
Last updated
7 Nov 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Anatase Spine Surgery Navigation System in people with Cervical Spine Fusion, run by China Medical University Hospital.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 7 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Cheng-Di Chiu (04-22052121 ext. 15033, 022459@tool.caaumed.org.tw), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Difference between the actual and virtual (navigation system) distance of the probe. (time frame: during the surgery). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Nov 2023.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in