Whole Body VibrationNCT06172244
Acute Effect of Whole Body Vibration on Reaction Speed and Proprioception
A study testing Applying with whole body vibration device in people with Whole Body Vibration, run by Çağtay Maden at 1 site in Turkey (Türkiye).
Trial summary
It will be determined whether the application of whole body vibration has an immediate effect on upper extremity reaction speed and proprioception. Read more about this study
- Who is it for?
- Ages 18 to 25 yearsHealthy volunteers can take part
- Conditions the study is for
- Whole Body Vibration
- What is being tested?
- Applying with whole body vibration device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 62 participants
- Where
- 1 siteTurkey (Türkiye)
- Study dates
- 1 Jul 2023to 30 Nov 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 25 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- Healthy individuals between the ages of 18-25
- Those who do not have any orthopedic problems in the upper extremity
- Individuals without any neurological problems
- Those who volunteer to participate in the study
Who cannot join
- Those who have vertigo
Trial locations and contacts
1 site in 1 country.
Turkey (Türkiye)1 site
Gaziantep İslamic Science and Technology University
Gaziantep, Şahinbey, 27000
About this study
Official title: Acute Effect of Whole Body Vibration on Reaction Speed and Proprioception in the Upper Extremity in Healthy Subjects
It will be determined whether the application of whole body vibration has an immediate effect on upper extremity reaction speed and proprioception.
Read the detailed description
Muscles and tendons are among the mechanisms affected by whole body vibration. In this way, it is thought that TVV indirectly affects the reaction speed of individuals. In the light of this information, this study was planned to investigate how whole body vibration application affects proprioception and reaction speed. The reaction rate and instantaneous effect of the virion given at 30 Hz and 2 mm amplitude in the push-up position on proprioception will be investigated. The aim of this study is to investigate the instantaneous effect of whole body vibration on reaction speed and proprioception in the upper extremity in healthy individuals.
- Conditions
- Whole Body Vibration
- Being tested
- Applying with whole body vibration device
- Keywords
- whole body vibration, healthy subject, reaction time, proprioception, Upper Extremity
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Applying with whole body vibration deviceOther
A total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest.
| Study group | Role | What they receive |
|---|---|---|
| Whole body vibration | Experimental | A total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest. Receives: Other: Applying with whole body vibration device |
What is being measured
The primary outcome is the main question the study is designed to answer.
Nelson Hand Reaction Test
The participant is asked to sit in the chair with the forearm and hand comfortably resting on the table. The tips of the thumb and index finger are positioned 8-10 cm away from the table, with the tops of the thumb and index finger parallel to each other. The tester asks the individual to hold the ruler between his thumb and index finger. At the same time, the patient is asked to look directly at the middle point of the ruler while holding it between his fingers. As soon as the ruler is released, the person is told to catch the ruler with his thumb and forefinger. The ruler is left and the numerical value on the upper edge of the subject's thumb, where the subject grasps the ruler, is read and recorded.
Measured: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
Reaction Rate Evaluation with Sway Medical Smartphone Application
The person will sit comfortably on a chair and hold the smartphone with the thumbs on both sides. When the orange screen appears, the phone should quickly rotate the screen in the desired direction. Once you will do the test to learn the application. Then, the application is made three times and the reaction rate is calculated by taking the average time of these three applications.
Measured: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
Upper extremity proprioception measurement
Elbow flexion, shoulder flexion and abduction 30 and 60 degree angles were measured with a digital goniometer. The elbow and shoulder positions were brought to the desired angle and they were asked to return to the same angle. The angle of deviation was recorded.
Measured: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted15 Dec 2023
- Study start1 Jul 2023
- Primary completion1 Nov 2023
- Study completion30 Nov 2023
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Whole Body VibrationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Basic science
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- A total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest.
- Masking
- None (open label)
- Enrolment
- 62 participants (actual)
Sponsor and investigators
- Lead sponsor
- Çağtay Maden
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor-investigator, Çağtay Maden, Gaziantep Islam Science and Technology University
- Investigators
- Çağtay MADEN, Principal investigator, Gaziantep İslamic Science and Technology University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06172244
- Sponsor's protocol ID
- 2023/266
- Status last verified
- Jun 2023
- First submitted
- 7 Dec 2023
- Last updated
- 2 Apr 2024
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 2 Apr 2024. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Acute Effect of Whole Body Vibration on Reaction Speed and Proprioception in the Upper Extremity in Healthy Subjects
- ClinicalTrials.gov ID
- NCT06172244
- Acronym / sponsor ID
- 2023/266
- Conditions
- Whole Body Vibration
- Keywords
- whole body vibration, healthy subject, reaction time, proprioception, Upper Extremity
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 62 participants (actual)
- Lead sponsor
- Çağtay MadenUniversity, hospital or other
- Study start
- 1 Jul 2023 (actual)
- Primary completion
- 1 Nov 2023 (actual)
- Study completion
- 30 Nov 2023 (actual)
- First posted
- 15 Dec 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
It will be determined whether the application of whole body vibration has an immediate effect on upper extremity reaction speed and proprioception.
Detailed description
Muscles and tendons are among the mechanisms affected by whole body vibration. In this way, it is thought that TVV indirectly affects the reaction speed of individuals. In the light of this information, this study was planned to investigate how whole body vibration application affects proprioception and reaction speed. The reaction rate and instantaneous effect of the virion given at 30 Hz and 2 mm amplitude in the push-up position on proprioception will be investigated. The aim of this study is to investigate the instantaneous effect of whole body vibration on reaction speed and proprioception in the upper extremity in healthy individuals.
Study design
- Primary purpose
- Basic science
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- A total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest.
| Arm | Type | Receives |
|---|---|---|
| Whole body vibration | Experimental | Other: Applying with whole body vibration deviceA total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest. |
Who may qualify
- Ages
- 18 to 25 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (4 listed)
- Healthy individuals between the ages of 18-25
- Those who do not have any orthopedic problems in the upper extremity
- Individuals without any neurological problems
- Those who volunteer to participate in the study
Key exclusion criteria (1 listed)
- Those who have vertigo
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Applying with whole body vibration deviceA total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest. | Other | Whole body vibration |
Primary outcome
Nelson Hand Reaction Test
Time frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
The participant is asked to sit in the chair with the forearm and hand comfortably resting on the table. The tips of the thumb and index finger are positioned 8-10 cm away from the table, with the tops of the thumb and index finger parallel to each other. The tester asks the individual to hold the ruler between his thumb and index finger. At the same time, the patient is asked to look directly at the middle point of the ruler while holding it between his fingers. As soon as the ruler is released, the person is told to catch the ruler with his thumb and forefinger. The ruler is left and the numerical value on the upper edge of the subject's thumb, where the subject grasps the ruler, is read and recorded.
Reaction Rate Evaluation with Sway Medical Smartphone Application
Time frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
The person will sit comfortably on a chair and hold the smartphone with the thumbs on both sides. When the orange screen appears, the phone should quickly rotate the screen in the desired direction. Once you will do the test to learn the application. Then, the application is made three times and the reaction rate is calculated by taking the average time of these three applications.
Upper extremity proprioception measurement
Time frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
Elbow flexion, shoulder flexion and abduction 30 and 60 degree angles were measured with a digital goniometer. The elbow and shoulder positions were brought to the desired angle and they were asked to return to the same angle. The angle of deviation was recorded.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Apr 2024.
Related trials for Whole Body Vibration
Not yet recruiting
Effects of Whole-Body Vibration and Cervical Stabilization With Core Stabilization in Young Adults With Non-Specific Low Back Pain
Nonspecific Low Back Pain
RecruitingPhase 4
Improving Morning Strength and Cognitive Performance Using Caffeine or Whole-body Vibration.
Vibration Therapy, Caffeine
Not yet recruiting
Stair Biomechanics and Vibration Study After ACLR
Anterior Cruciate Ligament Reconstruction (ACLR), Anterior Cruciate Ligament Injury
Active, not recruiting
Hypopressive-Core Stabilization With and Without Whole-Body Vibration in Postpartum Pelvic Girdle Pain
Postpartum Pelvic Girdle Pain
Active, not recruiting
Health Benefits of Whole-body Vibration
Whole-body Vibration
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Çağtay MADEN principal investigator
Gaziantep İslamic Science and Technology University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Applying with whole body vibration device in people with Whole Body Vibration, run by Çağtay Maden at 1 site in Turkey (Türkiye).
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 2 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Nelson Hand Reaction Test (time frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Apr 2024.