AzTrials
AzTrials

AsthmaNCT06211998

Comparison of Mesh Nebulizer and Compressor Nebulizer With Pulmonary Function Test in Pediatric Asthma Attacks

A study testing Group 1 and Group 2 in people with Asthma and Asthma in Children, run by Berker Okay at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Asthma is a worldwide health problem and is one of the most common chronic diseases of childhood in most countries. Symptoms begin before the age of 5 years in 80% of children with asthma, but the diagnosis is not always easy. Read more about this study

Who is it for?
Ages 7 to 15 years
Conditions the study is for
Asthma, Asthma in Children
What is being tested?
Group 1 and Group 2
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
80 participants
Where
1 siteTurkey (Türkiye)
Study dates
1 Aug 2022to 1 Aug 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 7 to 15 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • Asthma attack patients who need inhaler therapy (salbutamol)
  • Patients aged 7-15 years and whose families gave consent for the study

Who cannot join

  • Patients with neuromotor impairment
  • Patients with underlying chronic disease (neurological disease such as epilepsy or congenital heart disease)
  • Patients with obesity or malnutrition (to equalize drug dose efficacy)
  • Patients with those receiving adrenaline, budesonide or ipratropium bromide therapy
  • Patients who have used a long-acting bronchodilator in the last 12 hours or a short-acting bronchodilator in the last 2 hours
  • Patients with fever above 37.5°C
Show all 11Show fewer
  • Patients with a saturation value below 92% at the time of admission
  • Patients with severe asthma attack
  • Patients with respiratory failure
  • Patients who had problems in performing the test (such as mental retardation, patient incompatibility)
  • Patients with diseases involving the chest muscles and those with chronic lung diseases (such as cystic fibrosis, bronchiectasis)

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • UHS Haseki Training and Research Hospital

    Istanbul, Sultangazi, 34304

Other trials in Turkey (Türkiye)

About this study

Official title: Comparison of Mesh Nebulizer and Compressor Nebulizer on Pulmonary Function Test in Children Presenting With Asthma Attack: A Double-Blind Randomized Comparative Clinical Trial

Asthma is a worldwide health problem and is one of the most common chronic diseases of childhood in most countries. Symptoms begin before the age of 5 years in 80% of children with asthma, but the diagnosis is not always easy. The National Asthma Education and Prevention Program (NAEPP) expert panel recommends spirometry testing for children over 5 years of age. Spirometry measurements include forced vital capacity (FVC) and the forced expiratory volume in first second (FEV1). Airflow obstruction is defined as FEV1 reduced to less than 80 percent predicted and an FEV1/FVC ratio of less than 0.85 (85 percent). Reference values are based on age, height, sex, and race. Forced expiratory flow between 25 and 75 percent of vital capacity (FEF25-75) less than 65 percent correlates with reversible airflow obstruction in children with normal FEV1 and may be a useful measure in this subgroup.

In the spirometry test, FEV1, FVC, FEF 25-75% values are valuable for the follow-up of asthma. While the FEV1/FVC ratio is above 80% in healthy children, it may decrease below 75% in diseases such as asthma. Likewise, FEV1 and FEF can be found to be low in 50-75% of asthma patients. In addition, these values can be used to determine the effectiveness of the inhaler given with the nebulizer given during the attack. Spirometry should be performed before and after administration of a bronchodilator to assess for reversibility (bronchodilator response [BDR]) even in children with a normal baseline FEV1 because many of these children will still have a BDR (both within the normal range and sometimes also supranormal) after treatment. Significant reversibility is indicated by an increase in FEV1 of ≥12 percent from baseline after administration of a short-acting bronchodilator. This definition for BDR positivity was established primarily in adults. An increase in FEV1 of ≥8 percent may be a better definition for BDR in children.

Read more

Inhaled short-acting beta-2 agonists, particularly albuterol (salbutamol), are the standard emergent treatment for acute asthma exacerbations in all patients based upon adult data. It is recommended to be given every 20 minutes in case of need for repeated doses in mild and moderate asthma attacks. Different types of nebulizers can be used for inhaler therapy; they can convert drugs into vapor form with sound waves, compressed air or by using electrical energy. While compressor nebulizers convert the liquid drug into aerosol form with compressed air, mesh nebulizers convert the drug into aerosol form with the vibrations they create with the help of electrical energy. Mesh nebulizers are more effective than other types of nebulizers, and the amount left in the chamber is less than other models, and it can decompose the drug into smaller particles and reach the more extreme branches of the lung.

In our study, the investigators aimed to determine which nebulizer type is more effective by comparing the effects of mesh nebulizer and compressor nebulizer on spirometry test in children presenting with asthma attack. Thus, the investigators planned to find the most comfortable and effective method for patients by determining the appropriate nebulization technique for patients.

Being tested
Group 1, Group 2
Keywords
Asthma, Child, Compressor Nebulizer, Mesh Nebulizer, Pulmonary function test
Medical subject headings
Asthma

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Group 1Device

    Salbutamol inhaler, Omron® CompAIR Pro NE-C900 Compressor Nebulizer (Omron Healthcare Co., Ltd., Kyoto, Japan) was used in Group 1

  • Group 2Device

    Salbutamol inhaler, Mesh nebulizer (Aerogen Solo®, Aerogen Ltd, Galway, Ireland) was used in Group 2

Study groups in NCT06211998
Study groupRoleWhat they receive
Group receiving inhaled treatment with compressor nebulizerActive comparatorSalbutamol inhaler, Omron® CompAIR Pro NE-C900 Compressor Nebulizer (Omron Healthcare Co., Ltd., Kyoto, Japan) was used in Group 1
Receives: Device: Group 1
Group receiving inhaled treatment with mesh nebulizerActive comparatorSalbutamol inhaler, Mesh nebulizer (Aerogen Solo®, Aerogen Ltd, Galway, Ireland) was used in Group 2
Receives: Device: Group 2

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mesh nebulizer improves pulmonary function test results more effectively in children

    Pulmonary function test results in children using mesh nebulizers may be improving more effectively.

    To compare mesh and compressor nebulizers, we planned to compare FEV1, FVC, FEV1/FVC, FEF 25-75 and PEF in pulmonary function testing.

    Measured: 1 hour

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jan 2024
  2. Study start1 Aug 2022
  3. Primary completion15 Jul 2023
  4. Study completion1 Aug 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Quadruple blind
Who is masked
Participant, Care provider, Investigator, Outcomes assessor
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06211998
Sponsor's protocol ID
140-2022
Status last verified
Jan 2024
First submitted
25 Dec 2023
Last updated
18 Jan 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Dunne RB, Shortt S. Comparison of bronchodilator administration with vibrating mesh nebulizer and standard jet nebulizer in the emergency department. Am J Emerg Med. 2018 Apr;36(4):641-646. doi: 10.1016/j.ajem.2017.10.067. Epub 2017 Oct 31.

    PubMed 29167030
  • Pitance L, Vecellio L, Leal T, Reychler G, Reychler H, Liistro G. Delivery efficacy of a vibrating mesh nebulizer and a jet nebulizer under different configurations. J Aerosol Med Pulm Drug Deliv. 2010 Dec;23(6):389-96. doi: 10.1089/jamp.2010.0816. Epub 2010 Oct 19.

    PubMed 20958144
  • Yuksel H, Yasar A, Acikel A, Topcu I, Yilmaz O. Two different methods of lidocaine inhalation before diagnostic flexible bronchoscopy: effects on post-bronchoscopy respiratory symptoms. Turk J Med Sci. 2021 Aug 30;51(4):2101-2106. doi: 10.3906/sag-2012-130.

    PubMed 34013705
  • Okay B, Hatipoglu HU, Okay ZU, Sahin K, Yasar A. Comparing mesh and compressor nebulizers in pulmonary function test in pediatric asthma attacks: A double-blind randomized comparative clinical trial. Respir Med. 2025 Mar;238:107966. doi: 10.1016/j.rmed.2025.107966. Epub 2025 Jan 28.

    PubMed 39884589

Questions about this trial

What is this clinical trial studying?

A study testing Group 1 and Group 2 in people with Asthma and Asthma in Children, run by Berker Okay at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 11 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jan 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mesh nebulizer improves pulmonary function test results more effectively in children (time frame: 1 hour). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06211998, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jan 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in