AzTrials
AzTrials

Aortic StenosisNeo2BAVNCT06212050

Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis

An observational study of Aortic Stenosis and Transcatheter Aortic Valve Implantation, run by National University of Ireland, Galway, Ireland at 3 sites in 3 countries.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record

Search all trials

Trial summary

The goal of the NEO2 BAV registry is to investigate the safety, effectiveness, and clinical performance of TAVI using the ACURATE neo2 valve in patients with severe BAV stenosis. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Transcatheter Aortic Valve Implantation
Type of treatment
Medical device
How many people
200 participants
Where
3 sitesin 3 countries
Study dates
15 Sep 2023to 30 Jun 2024
Phase
Observational

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients with severe BAV stenosis and treated with TAVI using ACURATE neo2 THV.

Who may be able to join

  • Patients aged ≥ 18 years
  • Patients with severe AS and any BAV phenotype and indicated for TAVI based on the local heart team decision.
  • Patient treated with ACURATE neo2 THV.

Who cannot join

  • Failure to obtain the patient's consent
  • Failure to obtain the follow-up clinical data or cardiac imaging required for the study primary endpoints.

Trial locations and contacts

3 sites in 3 countries.

3 sites in 3 countries

Germany1 site
  • Kerckhoff Heart and Lung Centre

    Bad Nauheim

Other trials in Germany

Ireland1 site
  • Galway University Hospital

    Galway

Other trials in Ireland

Sweden1 site
  • Karolinska University Hospital

    Stockholm

Other trials in Sweden

About this study

Official title: Investigator Initiated Multicenter Study to Evaluate the Feasibility, Safety and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis - The Neo2 BAV Registry

The goal of the NEO2 BAV registry is to investigate the safety, effectiveness, and clinical performance of TAVI using the ACURATE neo2 valve in patients with severe BAV stenosis.

The clinical, procedural, and imaging characteristics will be collected from patients with severe BAV stenosis, regardless of the phenotype, and treated with TAVI using the ACURATE neo2 bioprosthesis worldwide.

Read the detailed description

As the use of TAVI in BAV anatomy expands, it is important to systematically evaluate clinical outcomes from various THV technologies among BAV patients. It is essential to consider short-, and longer-term events among patients with BAV undergoing TAVI. Short-term outcomes of interest include THV embolization, PVL, residual transvalvular gradients and patient prosthesis mismatch, aortic root rupture, the requirement for new PPI, and stroke. Longer-term term clinical events of interest include quality of life, THV durability, freedom from reintervention, maintained coronary access, the possibility of redo-TAVI, and mortality.

The ACURATE neo2 THV has design features that make it possible to successfully treat severe BAV stenosis and yield optimal short- and longer-term outcomes. A new active sealing skirt is designed to minimize residual PVL; this is especially relevant given the presence of severe calcifications in BAV. The supra-annular leaflet position is also likely to provide excellent haemodynamics and durability since they sit above the heavily calcified native valve leaflet calcification. The upper crown and stabilizing arches and the top-down deployment of the ACURATE neo2 should reduce the risk of device embolization. It is unclear however if the self-expanding frame of the neo2 has the optimal radial force to treat patients with severe calcification.

The plan is to collect systematic clinical, procedural, and imaging data on a large series of patients with severe symptomatic BAV stenosis who underwent TAVI using the ACURATE neo2 THV. This information will show if the ACURATE neo2 is suitable to treat BAV morphology and determine if there are specific BAV subtypes that are more suitable for alternative treatment strategies. It is also envisaged that this study will inform the procedural execution of ACURATE neo2 THV in BAV morphology and inform future iteration design of the ACURATE neo THV series.

All imaging data (Echocardiography, angiography, aortography and MSCT) will be meticulously analyzed in an independent imaging Core Lab (CORRIB Core Lab, University of Galway, Galway, Ireland).

The in-depth imaging analysis will allow the identification of patients that are suitable for TAVI using the ACURATE neo2 system and highlight patient or procedural features that render TAVI at elevated risk of adverse outcomes. Furthermore, a mechanistic understanding of the device-host interaction will be examined on post-TAVI multislice computed tomography (MSCT) and other available post-TAVI imaging studies.

Being tested
Transcatheter Aortic Valve Implantation
Keywords
ACURATE neo2, Aortic stenosis, Bicuspid Aortic valve
Medical subject headings
Aortic Valve Stenosis, Bicuspid Aortic Valve Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Transcatheter Aortic Valve ImplantationDevice

    Also called ACURATE neo2 Aortic valve system

    TAVI in patients with severe BAV stenosis using ACURATE neo2

Study groups in NCT06212050
Study groupRoleWhat they receive
Patients with severe symptomatic BAV stenosisPatients with severe symptomatic BAV stenosis who underwent TAVI using the ACURATE neo2 THV.
Receives: Device: Transcatheter Aortic Valve Implantation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. VARC-3 device success

    1. Number of patients with technical success.
    2. Number of patients with death from any cause.
    3. Number of patients with surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication.
    4. Number of patients with intended performance of the valve (mean gradient <20 mmHg, peak velocity <3 m/s, Doppler velocity index ≥0.25, and less than moderate AR), defined as the presence of all of the following:

    Measured: 30-Day

  2. VARC-3 early safety

    1. Number of patients with death from any cause.
    2. Number of patients with stroke.
    3. Number of patients with VARC type 2-4 bleeding.
    4. Number of patients with major vascular, access-related, or cardiac structural complication.
    5. Number of patients with acute kidney injury stage 3 or 4.
    6. Number of patients with moderate or severe aortic regurgitation
    7. Number of patients with new pacemaker due to procedure related conduction abnormalities
    8. Number of patients with surgery or intervention related to the device

    Measured: 30-Day

Secondary outcomes (2)
  1. VARC-3 clinical efficacy (at 1 year and thereafter)

    1. Number of patients with death from any cause.
    2. Number of patients with stroke.
    3. Number of patients with hospitalization (procedure or Valve related causes).

    Measured: 1-year

  2. Valve-related long-term clinical efficacy (at 5 years and thereafter)

    1. Number of patients with bioprosthetic Valve Failure (defined as: Valve related mortality OR Aortic valve re-operation/re-intervention or Stage 3 hemodynamic valve deterioration)
    2. Number of patients with stroke.
    3. Number of patients with VARC Type 2-4 bleeding secondary to or exacerbated by antiplatelet or anticoagulant agents, used specifically for valve-related concerns.

    Measured: 5-year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jan 2024
  2. Study start15 Sep 2023
  3. Primary completion1 Mar 2024
  4. Study completion30 Jun 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Retrospective
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06212050
Sponsor's protocol ID
C.A. 2961
Acronym
Neo2BAV
Status last verified
Jun 2024
First submitted
8 Nov 2023
Last updated
21 Jun 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: not decided yet

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in