The goal of this observational study is to learn about the verification of the effectiveness and visual acuity of LUMINA in patients after lens replacement due to cataracts. The main questions it aims to answer are: Evaluation of the effectiveness of the LUMINA lens in patients after lens replacement due to cataracts… Read more about this study

Who is it for?
Ages 40 to 81 yearsHealthy volunteers can take part
Conditions the study is for
Cataract
What is being tested?
LUMINA IOL
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
No sites listed yet
Study dates
9 Jun 2016to Dec 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 40 to 81 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Visual significant cataract with an expected positive effect of the surgery on the visual outcome.
  • ≥ 40 years of age
  • Calculated IOL power within the available diopter range

Who cannot join

  • Comorbidities causing postoperative visual impairment, such as degenerative macular pathology
  • Glaucoma with optic disk damage and visual field loss
  • Retinal dystrophies
  • Previous ocular surgeries, such as vitrectomy, corneal graft surgery
  • Lens subluxation
  • Significant eye trauma that may induce lens instability
Show all 9Show fewer
  • Congenital ocular anomalies
  • Endothelial cell count < 1200 cells/mm2
  • Previous known reading disabilities, such as dyslexia.

About this study

Official title: Prospective, Open-label Clinical Study to Evaluate the Efficacy and Function of the AkkoLens Accommodative Intraocular Acrylic Lens for the Treatment of Cataracts

The goal of this observational study is to learn about the verification of the effectiveness and visual acuity of LUMINA in patients after lens replacement due to cataracts.

The main questions it aims to answer are:

  • Evaluation of the effectiveness of the LUMINA lens in patients after lens replacement due to cataracts
  • Evaluation of the accommodative power of the LUMINA lens. Participants will have cataract surgery and the IOL LUMINA will be implanted in the sulcus.
Read the detailed description

This is an observational, prospective, longitudinal, and consecutive study involving patients with clinical cataract eligible for cataract surgery who opt for the implantation of the Lumina (Akkolens, Clinical BV, The Netherlands) accommodative lens. The study was conducted at the Cornea, Cataract, and Refractive Surgery Unit in Vissum Alicante, Miranza Group, Spain. The study adhered to the tenets of the Declaration of Helsinki (2013 version )and was approved by the Comite Etico de Investigacion Clinica Vissum Alicante.

The study group included 50 eyes of 25 patients, aged 40 to 81 years (mean 62.27 ± 10.81 years), with clinical cataract who were implanted with the Lumina accommodative IOL. The inclusion criteria of this study were as follows: patients with visual significant cataract with an expected positive effect of the surgery on the visual outcome. The patient had to be ≥ 40 years of age and with a calculated IOL power within the available diopter range. The exclusion criteria were comorbidities causing postoperative visual impairment such as degenerative macular pathology, glaucoma with optic disk damage and visual field loss, retinal dystrophies previous ocular surgeries such as vitrectomy , corneal graft surgery, lens subluxation or significant eye trauma that may induce lens instability, congenital ocular anomalies, endothelial cell count < 1200 cells/mm2 and previous known reading disabilities such as dyslexia. Only patients with less than 2 diopters (D) of corneal astigmatism were included in the study with no significant corneal irregularities (less than 0.5 microns of anterior corneal surface HOA) as measured by corneal topography (CSO, Costruzione Strumenti Oftalmici, Firenze, Italy). All patients were adequately informed and signed a consent form.

Preoperatively, all patients had a full ophthalmologic examination including the evaluation of the refractive status, keratometry, the distance and near visual acuities, slit lamp examination, applanation tonometry, and funduscopy. Distance and near visual acuity were measured with the ETDRS and the Radner reading chart (logarithm of reading acuity determination, logRAD), respectively. Other examinations included corneal topography Sirius/MS-39 (CSO, Costruzione Strumenti Oftalmici, Firenze, Italy), anterior segment optical coherence tomography MS-39 (CSO, Costruzione Strumenti Oftalmici, Firenze, Italy) or Casia2 (Tomey, Japan), posterior segment optical coherence tomography Cirrus OCT (Zeiss, Germany) and biometry IOL master 700 (Zeiss, Germany). The fixed optical power of the lens (i.e., the power required for an emmetropic eye) was calculated from optical biometry (IOL Master; Zeiss) by using proprietary Cþþ software integrated with Zemax ray-tracing software (Zemax, USA). The target refraction was plano in all cases that were included.

The same surgeon (JLA) performed all surgeries. All patients received retrobulbar anesthesia and mild sedation with midazolam. Adequate dilatation was obtained with intracameral mydriatics. The main corneal incision of 2.8 mm was placed temporally at the 180° meridian position in all eyes. A standard technique of phacoemulsification was performed followed by implantation of the Lumina in the sulcus plane of the eye by using a standard disposable injector system with an adapted, proprietary, AkkoLens butterfly cartridge. Postoperative topical therapy included a combination of topical antibiotics (ofloxacin 0.3%) and a steroid agent (dexamethasone 0.1%, Maxidex; Alcon, Spain).

The patients were evaluated during the follow up at five intervals: 1 day, 1 month, 3 months 6 months and a minimum of 12 months after surgery. In addition to the measurements listed in the preoperative protocol, the postoperative protocol included additional assessments of contrast sensitivity function in mesopic conditions (CSV 1000, VectorVision Ocular Health, Greenville, Ohio, USA) and the defocus curves. Monocular defocus curves were obtained with best distance refractive correction under low ambient light to keep an open pupil to minimize the undesirable effect of extended depth of focus owing to a small pupil, which can mask true accommodation. Negative and positive spherical lenses were added in 0.50 D steps, producing a stimulus for the eye to accommodate in the range from -5.00 to +2.00 D. The means of the measured visual acuities are summarized in mean defocus curves in which the measurements at 0.00 D and-2.50 D correspond to corrected distance visual acuity (CDVA) and corrected distance near visual acuity (CDNVA), respectively, and intermediate visual acuity corresponds to the measurement at -1.50 D. Depth of focus was evaluated from defocus curves at the levels of visual acuity of 0.10, 0.20, and 0.40 logMAR. The depth of focus for a particular eye was defined as the width of the defocus curve, in diopters, at a given level of visual acuity. The retinal optical quality was obtained using pyramidal aberrometry (Osiris, CSO, Italy) and optical quality analyzer system (OQAS, Visiomettrics SL, Spain) obtaining the MTF and PSF for different diameters and open field aberrometer (OFA, CSO, Italy) measured for distance and near.

Main outcome measures Primary: Distance and near visual acuities, defocus curve, accommodation, depth of focus.

Secondary: Contrast sensitivity function, optical quality assessment, PROMs (quality of vision and quality of life reported by the patients), complications.

Conditions
Cataract
Being tested
LUMINA IOL
Keywords
Intraocular lens, Accommodation
Medical subject headings
Cataract

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • LUMINA IOLDevice

    A standard technique of phacoemulsification was performed followed by implantation of the Lumina in the sulcus plane of the eye by using a standard disposable injector system with an adapted, proprietary, AkkoLens butterfly cartridge.

Study groups in NCT06231784
Study groupRoleWhat they receive
Lumina ImplantationOtherPatients implanted with LUMINA IOL
Receives: Device: LUMINA IOL

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Distance Vision measurements

    Distance and near visual acuities in LogMAR scale

    Measured: minimum 12 months

  2. Defocus curve measurements

    Defocus curve in diopters

    Measured: minimum 12 months

  3. Accommodation measurements

    Accommodation in diopters

    Measured: minimum 12 months

  4. Depth of focus measurements

    Depth of focus in diopters

    Measured: minimum 12 months

Secondary outcomes (3)
  1. Contrast sensitivity function

    Contrast sensitivity function in cycles per degrees

    Measured: minimum 12 months

  2. Optical quality assessment

    Optical quality assessment in microns, PROMs (quality of vision and quality of life reported by the patients) considering a score from 1 (the best situation) to 5 (the worst situation)

    Measured: minimum 12 months

  3. Complications

    Complications not requiring units of measure

    Measured: minimum 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Jan 2024
  2. Study start9 Jun 2016
  3. Primary completionDec 2023
  4. Study completionDec 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
LUMINA IOL
Masking
None (open label)
Enrolment
25 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06231784
Sponsor's protocol ID
Lumina
Status last verified
Jan 2024
First submitted
10 Jan 2024
Last updated
30 Jan 2024
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Alio JL, Simonov A, Plaza-Puche AB, Angelov A, Angelov Y, van Lawick W, Rombach M. Visual Outcomes and Accommodative Response of the Lumina Accommodative Intraocular Lens. Am J Ophthalmol. 2016 Apr;164:37-48. doi: 10.1016/j.ajo.2016.01.006. Epub 2016 Jan 29.

    PubMed 26829595
  • Alio JL, Simonov AN, Romero D, Angelov A, Angelov Y, van Lawick W, Rombach MC. Analysis of Accommodative Performance of a New Accommodative Intraocular Lens. J Refract Surg. 2018 Feb 1;34(2):78-83. doi: 10.3928/1081597X-20171205-01.

    PubMed 29425385

Questions about this trial

What is this clinical trial studying?

A study testing LUMINA IOL in people with Cataract, run by Vissum, Instituto Oftalmológico de Alicante.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 30 Jan 2024. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Distance Vision measurements (time frame: minimum 12 months). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06231784, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jan 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Efficacy of the AkkoLens IOL in Patients With Cataract | AzTrials