AzTrials
AzTrials

Mechanical Ventilation ComplicationAVIMNCT06236685

Optimizing the Assessment of Mechanical Ventilation by Integrating Advanced Monitoring Techniques [AVIM]

A study testing Electric impedance tomography in people with Mechanical Ventilation Complication and Ventilator-Induced Lung Injury, run by Czech Technical University in Prague at 1 site in Czechia.

Enrolling by invitation

Enrolling by invitation. The study team selects and invites participants, usually from an existing group of patients.

Sites and contacts
Official record
Search all trials

Trial summary

The aim of this study is to collect synchronized data from multiple monitoring techniques of mechanical ventilation (pressure/flow waves from the ventilator, electrical impedance tomography - EIT, esophageal pressure, capnography) in patients ventilated either on intensive care units or during anesthesia and evaluate… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Electric impedance tomography
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteCzechia
Study dates
22 Apr 2024to Dec 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • mechanical ventilation for anesthesia or in intensive care unit

Who cannot join

  • disagreement with enrollment or incapacity to understand the patient information leaflet
  • contraindications to electric impedance tomography (skin lesions in the place of electrode placement etc.)
  • necessity to use a defined ventilator setting outside the study protocol

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Czechia1 site
  • Military University Hospital

    Prague, 16902

Other trials in Czechia

About this study

Official title: Optimizing the Assessment of Mechanical Ventilation by Integrating Advanced Monitoring Techniques

The aim of this study is to collect synchronized data from multiple monitoring techniques of mechanical ventilation (pressure/flow waves from the ventilator, electrical impedance tomography - EIT, esophageal pressure, capnography) in patients ventilated either on intensive care units or during anesthesia and evaluate the data by detailed mathematical analysis, to test three hypotheses:

  1. Various published methods of calculation of the expiratory time constant provide different results in most cases.
  2. Inhomogeneous ventilation (as described by EIT) affects the form of the expiratory flow curve and thus the calculated expiratory time constants.
  3. The calculation of mechanical energy transferred to the lungs is affected by the chosen technique and length of the inspiratory pause maneuver.

This study does not test any new or non-standard methods and does not in any way interfere with the course of treatment indicated by the clinician, apart from extending the monitoring techniques.

Read the detailed description

Mechanical ventilation is known to cause various complications, generally known as ventilator induced lung injury. Thus, detailed monitoring is essential. However, data interpretation is complicated in clinical practice. The investigators aim to collect synchronized data from multiple monitoring techniques of mechanical ventilation (pressure/flow waves from the ventilator, electrical impedance tomography - EIT, esophageal pressure, capnography) in patients ventilated either on intensive care units or during anesthesia and evaluate the data by detailed mathematical analysis. The results will be used to explore the complexity of seemingly simple and often used calculations describing the course of mechanical ventilation - mostly the expiratory time constant and amount of mechanical energy transferred to the lungs. The investigators primarily aim to test three hypotheses:

  1. Various published methods of calculation of the expiratory time constant provide different results in most cases.
  2. Inhomogeneous ventilation (as described by EIT) affects the form of the expiratory flow curve and thus the calculated expiratory time constants.
  3. The calculation of mechanical energy transferred to the lungs is affected by the chosen technique and length of the inspiratory pause maneuver.

For this, the investigators plan to recruit 50 patients undergoing general anesthesia with controlled mechanical ventilation and 50 patients hospitalized on intensive care units. Monitoring of those patients will be protocolized and will in all cases include pressure/flow monitoring of the mechanical ventilator, capnography, and electrical impedance tomography. Esophageal pressure monitoring will be introduced where indicated by the clinician or where nasogastric tube insertion will be indicated (as the pressure can be measured by a combined catheter).

This study thus does not test any new or non-standard methods and does not in any way interfere with the course of treatment indicated by the clinician, apart from extending the monitoring techniques. Patient data will be anonymized and all the enrolled patients or their families will sign an informed consent as agreed by the ethical committee of our hospital.

Being tested
Electric impedance tomography
Keywords
electrical impedance tomography, expiratory time constant, mechanical energy, lung protective ventilation, ventilator-induced lung injury, expiratory flow, inspiratory hold maneuver
Medical subject headings
Ventilator-Induced Lung Injury

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Electric impedance tomographyDevice

    Also called EIT

    EIT is rarely used during general anesthesia for standard procedures. In the anesthesia arm, all patients will be monitored by EIT.

Study groups in NCT06236685
Study groupRoleWhat they receive
General anesthesiaExperimentalPatients undergoing general anesthesia with mechanical ventilation will be monitored by electrical impedance tomography in addition to standard monitoring. Moreover, esophageal pressure catheter will be used in cases where indicated by clinician or in case of an indication of nasogastric tube, as esophageal pressure can be measured by a combined catheter.
Receives: Device: Electric impedance tomography
Intensive Care UnitExperimentalPatients ventilated in the ICU for various reasons will receive standard care, including advanced monitoring of mechanical ventilation.
Receives: Device: Electric impedance tomography

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Expiratory time constant

    Time [in seconds], in which the lungs exhale 63% of the total volume.

    Measured: 2 minutes after an intervention or a change in the ventilator settings

  2. Mechanical energy transferred to the lungs

    Mechanical energy (alternatively referred to as mechanical work) [in Joules] is the energy delivered to the respiratory system during a single inspiration cycle.

    Measured: 2 minutes after an intervention or a change in the ventilator settings

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Feb 2024
  2. Study start22 Apr 2024
  3. Primary completionDec 2027 (estimated)
  4. Study completionDec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Parallel groups
Model description
The study will be conducted on patients provided with mechanical ventilation either on intensive care units or during anesthesia. Extended monitoring of ventilation, including electric impedance tomography and esophageal pressure readings will be applied.
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06236685
Sponsor's protocol ID
AVIM
Acronym
AVIM
Status last verified
Jun 2024
First submitted
24 Jan 2024
Last updated
28 Jun 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: If any particularly interesting cases arise, the investigators plan to share the individual monitoring data together with the study protocol as anonymized case studies, either published or upon request to other researchers.

Publications

  • Karagiannidis C, Waldmann AD, Roka PL, Schreiber T, Strassmann S, Windisch W, Bohm SH. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study. Crit Care. 2018 Sep 21;22(1):221. doi: 10.1186/s13054-018-2137-3.

    PubMed 30236123
  • Brunner JX, Laubscher TP, Banner MJ, Iotti G, Braschi A. Simple method to measure total expiratory time constant based on the passive expiratory flow-volume curve. Crit Care Med. 1995 Jun;23(6):1117-22. doi: 10.1097/00003246-199506000-00019.

    PubMed 7774225
  • Candik P, Rybar D, Depta F, Sabol F, Kolesar A, Galkova K, Torok P, Donicova V, Imrecze S, Nosal M, Donic V. Relationship between dynamic expiratory time constant tau(edyn) and parameters of breathing cycle in pressure support ventilation mode. Physiol Res. 2018 Dec 18;67(6):875-879. doi: 10.33549/physiolres.933750. Epub 2018 Sep 11.

    PubMed 30204464
  • Henderson WR, Molgat-Seon Y, Vos W, Lipson R, Ferreira F, Kirby M, Holsbeke CV, Dominelli PB, Griesdale DE, Sekhon M, Coxson HO, Mayo J, Sheel AW. Functional respiratory imaging, regional strain, and expiratory time constants at three levels of positive end expiratory pressure in an ex vivo pig model. Physiol Rep. 2016 Dec;4(23):e13059. doi: 10.14814/phy2.13059.

    PubMed 27923979
  • Vogt B, Pulletz S, Elke G, Zhao Z, Zabel P, Weiler N, Frerichs I. Spatial and temporal heterogeneity of regional lung ventilation determined by electrical impedance tomography during pulmonary function testing. J Appl Physiol (1985). 2012 Oct;113(7):1154-61. doi: 10.1152/japplphysiol.01630.2011. Epub 2012 Aug 16.

    PubMed 22898553

Questions about this trial

What is this clinical trial studying?

A study testing Electric impedance tomography in people with Mechanical Ventilation Complication and Ventilator-Induced Lung Injury, run by Czech Technical University in Prague at 1 site in Czechia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: enrolling by invitation, as of the sponsor's last update on 28 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Czechia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Expiratory time constant (time frame: 2 minutes after an intervention or a change in the ventilator settings). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06236685, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jun 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in