Cardiac Surgery PatientNCT06243445

Echocardiography With Bubble Test for Tip Location of Central Venous Catheters

An observational study of Cardiac Surgery Patient, run by Fondazione Policlinico Universitario Agostino Gemelli IRCCS at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this prospective observational study is to test the accuracy of the transthoracic echocardiography with bubble test to verify the location of the tip of the central venous catheter in patients undergoing cardiac surgery procedures. The main questions it aims to answer are: 1. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cardiac Surgery Patient
What is being tested?
Transthoracic echocardiography for central venous catheter tip location
Type of treatment
Injection or infusion
How many people
22 participants
Where
1 siteItaly
Study dates
1 Feb 2024to 27 Nov 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: The study will enroll patients of both sexes, aged> 18 years, with cardiovascular disease, who must undergo cardiac surgery

Who may be able to join

  • age > 18 years
  • written informed consent from the patient
  • intra-operative need for a central venous catheterization via the supra/infra clavicular right veins (centrally inserted central catheter, CICC)
  • indication to intra-operative Trans Esophageal Ultrasound (TEE) based on American Society of Anesthesiologists (ASA)

Who cannot join

  • contraindications to TEE based on American Society of Anesthesiologists (ASA) recommendations (esophageal or gastric diseases or previous surgery)
  • emergency procedures
  • central VAD already placed
  • need for a CICC via supra/infra clavicular left veins
  • need for a femorally inserted central catheter (FICC)
  • need for a peripherally inserted central catheter (PICC)
Show all 9Show fewer
  • tricuspid valve regurgitation
  • hemodynamic instability/ presence of an intra-aortic ballon pump (IABP)
  • absence of septal atrial defect

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • Gabriella Arlotta

    Roma, 00168

Other trials in Italy

About this study

Official title: Transthoracic Echocardiography With Bubble Test for Tip Location of Central Venous Catheters: a "Push to Bubble" Time Analysis

The goal of this prospective observational study is to test the accuracy of the transthoracic echocardiography with bubble test to verify the location of the tip of the central venous catheter in patients undergoing cardiac surgery procedures. The main questions it aims to answer are:

  1. Is there a difference in time elapsed between the injection of a saline solution (echogenic contrast) through a central venous catheter and the visualization of micro bubbles in right atrium ("push to bubbles" time) with transthoracic echocardiography, when the catheter tip is placed in four different positions identified by transesophageal echocardiography?
  2. Is there a difference in time for the right atrium to be completely filled by bubbles after saline injection in a central venous catheter with the tip placed in four different positions identified by transesophageal echocardiography?
  3. In what percentage of patients the acoustic window is good enough to evaluate "push to bubbles" time?
  4. Is there a difference in "push to bubbles" time between different echocardiographic projections?
  5. Is the bubbles flow laminar or turbulent in the four different positions?
  6. Is there a relation between "push to bubble" time and heart rate, blood pressure, pulmonary artery pressure, central venous pressure and cardiac output measured through a pulmonary artery catheter?

Participants will require simultaneously a central venous catheter and an intraoperative transesophageal echocardiography.

Read the detailed description

The placement of central vascular access devices (VADs), with cervical-thoracic or femoral insertion (such as CICC, Central Inserted Central Catheter, and FICC, Femoral Inserted Central Catheter), as well as peripheral insertion (PICC, Peripherally Inserted Central Catheter), is a common procedure for patients admitted to the Intensive Care Unit and for patients undergoing major surgery or prolonged infusion therapy.

To reduce the incidence of complications related to improper positioning of the central venous catheter, the tip should be positioned in the lower part of the superior vena cava or in the upper part of the right atrium near the cavo-atrial junction, identified by the crista terminalis.

Among the methods used to verify the correct tip placement, the intracavitary ECG method is strongly recommended by various international guidelines, and its use has been widely validated in terms of safety, efficacy, and accuracy. However, the intracavitary ECG method, based on the principle that the appearance of a high P-wave indicates the proximity of the tip to the cavo-atrial junction, has limitations when it comes to patients with non-sinus rhythm. Recent studies are validating the use of modified intracavitary ECG in patients with atrial fibrillation, but in other cases where a P-wave is not visible, the method is not applicable.

Various methods for ultrasound-guided placement and confirmation of the final tip position have been developed, also because the chest X-ray performed at the patient's bedside has proven to be a less accurate method due to the lack of definite findings of the cavo-atrial junction.

Transesophageal echocardiography (TEE), while being the method of choice as it allows direct visualization of the cavo-atrial junction and, therefore, the real position of both the guidewire and the tip of the catheter at the end of placement, remains an invasive method that is difficult to perform outside of cardiac operating rooms.

Transthoracic echocardiography may allow for the direct visualization of the tip of the VAD inside the heart chambers or indirectly assessing the tip's position by injecting echogenic contrast. Echogenic contrast refers to a rapid bolus of 5-20 ml of 0.9% saline solution, with or without the addition of 1 ml of air, vigorously shaken to create micro bubbles that can be easily visualized during the echocardiographic exam. The bolus is injected into the VAD once it has been positioned, and the micro bubbles are visualized in the right atrium, using transthoracic echocardiography. In nearly all studies, the VAD is considered in the correct position if the micro bubbles appear in the atrium within 2 seconds of injection ("push to bubble" time); otherwise, it is not considered correctly positioned if the bubbles appear after 2 seconds, but in one study, the adequate time was considered to be less than 500 ms. In almost all echocardiography studies, however, the reference method used to evaluate and confirm the VAD tip position has been chest radiography, which has been proven to be a less accurate method; moreover, literature shows significant variations in the indicative times for the visualization of micro bubbles that suggest incorrect position (range 0.5-2 seconds).

In this context, it could be useful to determine accurately if different "push to bubble" times are indicative for different positions of the VAD tip. For this purpose, the echogenic contrast (10 ml of 0,9% saline solution with the addition of 1 ml of air vigorously shaken to create micro bubbles) will be injected in the distal lumen of a VAD, whose tip is positioned in four different points, identified with using transesophageal echocardiography and the time from the contrast injection to the visualization of the bubbles in right atrium will be recorded using transthoracic echocardiography.

The four positions in which the catheter tip will be placed are: right atrium, cavo-atrial junction (CAJ), at 4 centimeters proximal to the CAJ in superior vena cava and at 8 centimeters to the CAJ. The catheter tip positions in right atrium and at CAJ will be directly evaluated using 2D and 3D transesophageal echocardiography, the other positions will be obtained moving the catheter back 4 and 8 centimeters from the CAJ. The transthoracic echocardiography will be carried out always by the same cardiologist trained in echocardiography unaware of the purpose of the study. The time measurements will be carried out always by the same cardiac anaesthesiologist, trained in echocardiography, unaware of the different catheter tip positions.

Being tested
Transthoracic echocardiography for central venous catheter tip location
Keywords
central venous catheter tip location, transthoracic echocardiography, bubble test

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Transthoracic echocardiography for central venous catheter tip locationDiagnostic test

    Measure of time between injection of echographic contrast in the distal lumen of a central venous catheter, inserted via supra/infra clavicular right veins, and visualization, using transthoracic echocardiography, of micro bubbles in right atrium with the catheter tip positioned under transesophageal ultrasound control in four different positions: right atrium, cavo-atrial junction (CAJ), at 4 centimeters proximal to CAJ, in superior vena cava and at 8 centimeters proximal to CAJ

Study groups in NCT06243445
Study groupRoleWhat they receive
Patients underwent cardiac surgery with need for a central venous catheterPatients underwent cardiac surgery with need for a central venous catheter and indication to intraoperative trans esophageal echocardiography
Receives: Diagnostic Test: Transthoracic echocardiography for central venous catheter tip location

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 1: right atrium, using subcostal 4-chamber view

    After the insertion of a central venous catheter in the supraclavicular right area by ultrasound guidance and direct Seldinger technique, under transesophageal ultrasound control, the catheter tip will be placed in right atrium, 2 cm below the CAJ; the echographic contrast will be injected through the proximal end of the catheter connected, via an Arrow-Johans adapter (Teleflex) and a dedicated ECG cable (Teleflex), to the transthoracic ultrasound machine. The video with the micro bubbles injected will be recorded by a cardiologist expert in echocardiography, unaware of the purpose of the study, using a subcostal 4-chamber view. Later a cardiac anesthesiologist, unaware of the purpose of the position of the catheter, will measure the time elapsed between the first positive wave created by the contrast injection on the intracavitary ECG recorded by the transthoracic ultrasound machine and the time in which the bubbles will appear in the right atrium.

    Measured: Immediately after the induction of anesthesia, placement of transesophageal probe and insertion of a central venous catheter. The video recorded will be analyzed immediately after the end of the procedure

  2. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 1: right atrium, using subcostal bicaval view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed in right atrium using subcostal bicaval view

    Measured: Immediately after the video recorded with the catheter tip placed in right atrium using subcostal 4-chamber view

  3. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 1: right atrium, using apical 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed in right atrium using apical 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip placed in right atrium using subcostal bicaval view

  4. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 2: cavo-atrial junction (CAJ), using subcostal 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at the CAJ, using subcostal 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip placed in right atrium using apical 4-chamber view

  5. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 2: cavo-atrial junction (CAJ), using subcostal bicaval view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at the CAJ, using subcostal bicaval view

    Measured: Immediately after the video recorded with the catheter tip placed at the CAJ using subcostal 4-chamber view

  6. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 2: cavo-atrial junction (CAJ), using apical 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at the CAJ, using apical 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip placed at the CAJ using subcostal bicaval view

  7. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 3: at 4 centimeters proximal to CAJ in superior vena cava, using subcostal 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at , 4 centimeters proximal to CAJ in superior vena cava, using subcostal 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip placed at the CAJ using apical 4-chamber view

  8. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 3: at 4 centimeters proximal to CAJ in superior vena cava, using subcostal bicaval view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using subcostal bicaval view

    Measured: Immediately after the video recorded with the catheter tip at 4 centimeters proximal to CAJ, in superior vena cava, using subcostal 4-chamber view

  9. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 3: at 4 centimeters proximal to CAJ in superior vena cava, using apical 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using apical 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip at 4 centimeters proximal to CAJ, in superior vena cava, using subcostal bicaval view

  10. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 4: at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at 8 centimeters proximal to the CAJ, using subcostal 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip at 4 centimeters proximal to the CAJ, in superior vena cava, using apical 4-chamber view

  11. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 4: at 8 centimeters proximal to CAJ, using subcostal bicaval view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at 8 centimeters proximal to the CAJ, using subcostal bicaval view

    Measured: Immediately after the video recorded with the catheter tip at 8 centimeters, using subcostal 4-chamber view

  12. Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 4: at 8 centimeters proximal to CAJ, using apical 4-chamber view

    With the procedure described above, the "push to bubble" time will be measured with the catheter tip placed at 8 centimeters proximal to the CAJ, using apical 4-chamber view

    Measured: Immediately after the video recorded with the catheter tip at 8 centimeters, using subcostal bicaval view

Secondary outcomes (62)
  1. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 1: right atrium, using subcostal 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip in right atrium using subcostal bicaval view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip in right atrium, using subcostal 4-chamber view

  2. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 1: right atrium, using subcostal bicaval view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip in right atrium using subcostal bicaval view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed in right atrium using subcostal bicaval view

  3. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 1: right atrium, using apical 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip in right atrium using apical 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed in right atrium, using apical 4-chamber view

  4. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 2: cavo-atrial junction (CAJ), using subcostal 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at the CAJ, using subcostal 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at cavo-atrial junction (CAJ), using subcostal 4-chamber view

  5. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 2: cavo-atrial junction (CAJ), using subcostal bicaval view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at the CAJ, using subcostal bicaval view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at cavo-atrial junction (CAJ), using subcostal bicaval

  6. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 2: cavo-atrial junction (CAJ), using apical 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at the CAJ, using apical 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at cavo-atrial junction (CAJ), using apical 4-chamber view

  7. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 3: 4 centimeters proximal to CAJ in superior vena cava, using subcostal 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using subcostal 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using subcostal 4-chamber view

  8. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 3: 4 centimeters proximal to CAJ in superior vena cava, using subcostal bicaval view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at 4 centimeters proximal to CAJ using subcostal bicaval view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using subcostal bicaval view

  9. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 3: 4 centimeters proximal to CAJ in superior vena cava, using apical 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using apical 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at 4 centimeters proximal to CAJ in superior vena cava, using apical 4-chamber view

  10. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 4: 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at 8 centimeters proximal to the CAJ, using subcostal 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  11. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 4: 8 centimeters proximal to CAJ, using subcostal bicaval view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at 8 centimeters proximal to the CAJ, using subcostal bicaval view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal bicaval view

  12. Difference in time for the right atrium to be completely filled by micro bubbles; measure with the catheter tip placed in position 4: 8 centimeters proximal to CAJ, using apical 4-chamber view

    The time needed for the right atrium to be completely filled by micro bubbles will be measured analyzing the video recorded with the catheter tip placed at 8 centimeters proximal to the CAJ, using apical 4-chamber view

    Measured: Immediately after measuring "push to time" in the video recorded with the catheter tip placed at 8 centimeters proximal to CAJ, using apical 4-chamber view

  13. Percentage in which "push to bubbles" time is evaluable using subcostal 4-chamber view

    To measure the percentage of the patients in which acoustic window is good enough to evaluate "push to bubbles" time using subcostal 4-chamber view.

    Measured: Immediately after every patient recruited will be evaluated with ultrasound in subcostal 4-chamber view

  14. Percentage in which "push to bubbles" time is evaluable using subcostal bicaval view

    To measure the percentage of the patients in which acoustic window is good enough to evaluate "push to bubbles" time using subcostal bicaval view.

    Measured: Immediately after every patient recruited will be evaluated with ultrasound in subcostal bicaval view

  15. Percentage in which "push to bubbles" time is evaluable using apical 4-chamber view

    To measure the percentage of the patients in which acoustic window is good enough to evaluate "push to bubbles" time using 4-chamber view.

    Measured: Immediately after every patient recruited will be evaluated with ultrasound in apical 4-chamber view

  16. Difference between "push to bubbles" time averages measured using the three different ultrasound views with the catheter tip in right atrium

    To determine if there is a significative difference between "push to bubbles" time averages measured using the three different ultrasound views: subcostal 4-chamber view, subcostal bicaval view and apical 4-chamber view with the catheter tip in right atrium

    Measured: Immediately after "push to bubbles" time will be evaluated in every patient recruited using the three different ultrasound views with the catheter tip in right atrium

  17. Difference between "push to bubbles" time averages measured using the three different ultrasound views with the catheter tip at the CAJ

    To determine if there is a significative difference between "push to bubbles" time averages measured using the three different ultrasound views: subcostal 4-chamber view, subcostal bicaval view and apical 4-chamber view with the catheter tip at the CAJ

    Measured: Immediately after "push to bubbles" time will be evaluated in every patient recruited using the three different ultrasound views with the catheter tip at the CAJ

  18. Difference between "push to bubbles" time averages measured using the three different ultrasound views with the catheter tip at 4 centimeters proximal to CAJ, in superior vena cava

    To determine if there is a significative difference between "push to bubbles" time averages measured using the three different ultrasound views: subcostal 4-chamber view, subcostal bicaval view and apical 4-chamber view with the catheter tip at 4 centimeters proximal to CAJ, in superior vena cava

    Measured: Immediately after "push to bubbles" time will be evaluated in every patient recruited using the three different ultrasound views with the catheter tip at 4 centimeters proximal to CAJ

  19. Difference between "push to bubbles" time averages measured using the three different ultrasound views with the catheter tip at 8 centimeters proximal to CAJ

    To determine if there is a significative difference between "push to bubbles" time averages measured using the three different ultrasound views: subcostal 4-chamber view, subcostal bicaval view and apical 4-chamber view with the catheter tip at 8 centimeters proximal to CAJ

    Measured: Immediately after "push to bubbles" time will be evaluated in every patient recruited using the three different ultrasound views with the catheter tip at 8 centimeters proximal to CAJ

  20. Evaluation of the quality of bubbles flow when the catheter tip is in the right atrium, using subcostal 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is in the right atrium, using subcostal 4-chamber view

    Measured: Immediately after Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed in right atrium using subcostal 4-chamber view

  21. Evaluation of the quality of bubbles flow when the catheter tip is in the right atrium, using subcostal bicaval view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is in the right atrium, using subcostal bicaval view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed in right atrium using subcostal bicaval view

  22. Evaluation of the quality of bubbles flow when the catheter tip is in the right atrium, using apical 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is in the right atrium, using apical 4-chamber view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed in right atrium using apical 4-chamber view

  23. Evaluation of the quality of bubbles flow when the catheter tip is at the CAJ using subcostal 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at the CAJ, using subcostal 4-chamber view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed in right atrium using subcostal 4-chamber view

  24. Evaluation of the quality of bubbles flow when the catheter tip is at the CAJ, using subcostal bicaval view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at the CAJ, using subcostal bicaval view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at the CAJ using subcostal bicaval view

  25. Evaluation of the quality of bubbles flow when the catheter tip is at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  26. Evaluation of the quality of bubbles flow when the catheter tip is at 4 centimeters proximal to CAJ, using subcostal bicaval view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at 4 centimeters proximal to CAJ, using subcostal bicaval view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal bicaval view

  27. Evaluation of the quality of bubbles flow when the catheter tip is at 4 centimeters proximal to CAJ, using subcostal apical 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at 4 centimeters proximal to CAJ, using subcostal apical 4-chamber view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal apical 4-chamber view

  28. Evaluation of the quality of bubbles flow when the catheter tip is at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  29. Evaluation of the quality of bubbles flow when the catheter tip is at 8 centimeters proximal to CAJ, using subcostal bicaval view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at 8 centimeters proximal to CAJ, using subcostal bicaval view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal bicaval view

  30. Evaluation of the quality of bubbles flow when the catheter tip is at 8 centimeters proximal to CAJ, using apical 4-chamber view

    To evaluate the percentage in which the bubbles flow is laminar or turbulent when the catheter tip is at 8 centimeters proximal to CAJ, using apical 4-chamber view

    Measured: Immediately after the evaluation of time for the right atrium to be completely filled by micro bubbles with the catheter tip placed at 8 centimeters proximal to CAJ, using apical 4-chamber view

  31. Correlation between heart rate and "push to bubbles" time measured with the catheter tip placed in right atrium using subcostal 4-chamber view

    To correlate the heart rate measured immediately before the ultrasound video recording with the catheter tip placed in right atrium using subcostal 4-chamber view

    Measured: Heart rate will be measured immediately before the ultrasound video recording with the catheter tip placed in right atrium using subcostal 4-chamber view

  32. Correlation between heart rate and "push to bubbles" time measured with the catheter tip placed at CAJ using subcostal 4-chamber view

    To correlate the heart rate measured immediately before the ultrasound video recording with the catheter tip placed at CAJ using subcostal 4-chamber view

    Measured: Heart rate will be measured immediately before the ultrasound video recording with the catheter tip placed at CAJ using subcostal 4-chamber view

  33. Correlation between heart rate and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, in superior vena cava, using subcostal 4-chamber view

    To correlate the heart rate measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, in superior vena cava using subcostal 4-chamber view

    Measured: Heart rate wil be measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, in superior vena cava using subcostal 4-chamber view

  34. Correlation between heart rate and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the heart rate measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Heart rate will be measured immediately before the ultrasound video recording with the catheter tip placed at at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  35. Correlation between systolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the systolic arterial blood pressure measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

    Measured: Systolic arterial blood pressure will be measured immediately before the ultrasound video recording the contrast injection with the catheter tip placed in right atrium, using subcostal 4-chamber view

  36. Correlation between systolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the systolic arterial blood pressure measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

    Measured: Systolic arterial blood arterial pressure will be measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

  37. Correlation between systolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the systolic arterial blood pressure recorded immediately before the ultrasound video with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Systolic arterial blood pressure is measured immediately before the ultrasound video recording the contrast injection with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  38. Correlation between systolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the systolic arterial blood pressure measured immediately before the ultrasound video with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Systolic arterial blood pressure is measured immediately before the ultrasound video with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  39. Correlation between mean arterial blood pressure and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the mean arterial blood measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

    Measured: Mean arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip in right atrium, using subcostal 4-chamber view

  40. Correlation between mean arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the mean arterial blood measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

    Measured: Mean arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip at CAJ, using subcostal 4-chamber view

  41. Correlation between mean arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the mean arterial blood measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Mean arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  42. Correlation between mean arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the mean arterial blood measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Mean arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  43. Correlation between diastolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the diastolic arterial blood measured immediately before the ultrasound video recording with the catheter tip placed in right atrium using subcostal 4-chamber view

    Measured: Diastolic arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip in right atrium, using subcostal 4-chamber view

  44. Correlation between diastolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the diastolic arterial blood measured immediately before the ultrasound video recording with the catheter tip placed at CAJ using subcostal 4-chamber view

    Measured: Diastolic arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip at CAJ, using subcostal 4-chamber view

  45. Correlation between diastolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the diastolic arterial blood measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ using subcostal 4-chamber view

    Measured: Diastolic arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  46. Correlation between diastolic arterial blood pressure and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the diastolic arterial blood measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ using subcostal 4-chamber view

    Measured: Diastolic arterial blood pressure is measured immediately before the ultrasound video recording with the catheter tip at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  47. Correlation between systolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the systolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

    Measured: Systolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip in right atrium, using subcostal 4-chamber view

  48. Correlation between systolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the systolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

    Measured: Systolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip at CAJ, using subcostal 4-chamber view

  49. Correlation between systolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the systolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Systolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  50. Correlation between systolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the systolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Systolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  51. Correlation between diastolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the diastolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

    Measured: Diastolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

  52. Correlation between diastolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the diastolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

    Measured: Diastolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

  53. Correlation between diastolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the diastolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Diastolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  54. Correlation between diastolic pulmonary artery pressure and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the diastolic pulmonary artery pressure measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Diastolic pulmonary artery pressure is measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  55. Correlation between central venous pressure and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the central venous pressure measured immediately before the ultrasound video recording with the catheter placed in right atrium, using subcostal 4-chamber view

    Measured: Central venous pressure is measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

  56. Correlation between central venous pressure and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the central venous pressure measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

    Measured: Central venous pressure is measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

  57. Correlation between central venous pressure and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the central venous pressure measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Central venous pressure is measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  58. Correlation between central venous pressure and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the central venous pressure measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Central venous pressure is measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

  59. Correlation between cardiac output and "push to bubbles" time measured with the catheter tip placed in right atrium, using subcostal 4-chamber view

    To correlate the cardiac output measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

    Measured: Cardiac output is measured immediately before the ultrasound video recording with the catheter tip placed in right atrium, using subcostal 4-chamber view

  60. Correlation between cardiac output and "push to bubbles" time measured with the catheter tip placed at CAJ, using subcostal 4-chamber view

    To correlate the cardiac output measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

    Measured: Cardiac output is measured immediately before the ultrasound video recording with the catheter tip placed at CAJ, using subcostal 4-chamber view

  61. Correlation between cardiac output and "push to bubbles" time measured with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the cardiac output measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Cardiac output is measured immediately before the ultrasound video recording with the catheter tip placed at 4 centimeters proximal to CAJ, using subcostal 4-chamber view

  62. Correlation between cardiac output and "push to bubbles" time measured with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    To correlate the cardiac output measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

    Measured: Cardiac output is measured immediately before the ultrasound video recording with the catheter tip placed at 8 centimeters proximal to CAJ, using subcostal 4-chamber view

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Feb 2024
  2. Study start1 Feb 2024
  3. Primary completion1 Apr 2024
  4. Study completion27 Nov 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
22 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06243445
Sponsor's protocol ID
5762
Status last verified
Nov 2025
First submitted
28 Jan 2024
Last updated
1 Dec 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Cardiac Surgery Patient, run by Fondazione Policlinico Universitario Agostino Gemelli IRCCS at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Difference in "push to bubbles" time recorded with the catheter tip placed in four different positions by three different ultrasound views; measure in position 1: right atrium, using subcostal 4-chamber view (time frame: Immediately after the induction of anesthesia, placement of transesophageal probe and insertion of a central venous catheter. The video recorded will be analyzed immediately after the end of the procedure). The study lists 12 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.