Photon Counting Detector CT Image Quality

A study testing Photon Counting Detector CT in people with Diagnostic Imaging and Tomography, X Ray Computed, run by Reto Sutter, MD at 1 site in Switzerland.

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

This study aims to compare subjective image quality and diagnostic accuracy of a photon counting detector computed tomography (PCD-CT) scanner compared with an energy integrating detector (EID)-CT scanner as the reference standard. Read more about this study

Who is it for?
Any age
What is being tested?
Photon Counting Detector CT
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
200 participants
Where
1 siteSwitzerland
Study dates
28 Jan 2024to 31 Dec 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Patient admitted for non-contrast enhanced CT scan of the upper or lower extremity at the radiology department of Balgrist University Hospital
  • Signed general consent ("Information zur Weiterverwendung gesundheitsbezogener Daten und Proben zu Forschungszwecken")
  • >18 years of age
  • Written consent to participate in this study

Who cannot join

  • Clinically significant concomitant disease states (e.g., renal failure, hepatic dysfunction, cardiovascular disease, etc.)
  • Women: pregnancy
  • Age below 18 years
  • Known or suspected non-compliance, drug or alcohol abuse
  • Inability to consent and/or follow the procedures of the investigation, e.g. due to language problems, psychological disorders, dementia, etc. of the subject
  • Enrolment of the PI, his/her family members, employees and other dependent persons
  • Body mass above 200 kg.
  • Body mass below 31 kg.

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • Balgrist University Hospital

    Zurich, Canton of Zurich, 8008

Other trials in Switzerland

About this study

Official title: Image Quality and Diagnostic Accuracy of Photon Counting Computed Tomography of the Upper and Lower Extremity

This study aims to compare subjective image quality and diagnostic accuracy of a photon counting detector computed tomography (PCD-CT) scanner compared with an energy integrating detector (EID)-CT scanner as the reference standard.

Read the detailed description

Computed tomography (CT) imaging plays a key role in diagnostic radiology, and is particularly valuable in assessing a myriad of musculoskeletal conditions (e.g. trauma, degenerative disorders, post-surgical follow-up, inflammatory diseases).

The vast majority of today's CT scanners are equipped with an energy-integrating detector (EID), which converts energy of incoming X-ray photons in a two-step process into electric signals: First, scintillators generate visible light, which in turn is converted to the electric signal by photodiodes.

Recently, photon-counting detector computed tomography (PCD-CT) scanners became commercially available and have been introduced to improve imaging performance through direct transformation of X-ray photons into electron hole pairs upon absorption in a semiconductor layer, generating an electrical signal proportional to the photon energy.

Current literature has shown that PCD-CT can offer higher spatial resolution, increased contrast-to-noise ratio, higher dose-efficiency, and inherent multi-spectral imaging capacity.

Moreover, the results from cadaver studies suggest that PCD-CT can preserve image quality with reduced radiation dose.

However, data on the diagnostic accuracy of PCD-CT compared to EID-CT is currently limited in the field of musculoskeletal radiology.

In addition to conventional CT acquisition, multi-spectral CT imaging in patients with gout and after trauma, is used in clinical routine to delineate materials with a specific absorption coefficient: in gout, urate crystals can be visualized, while after trauma, bone marrow edema can be detected. For EID-CT, different techniques for multi-spectral CT imaging are available (e.g. fast kV switching, dual source CT) which are widely used in clinical routine. Multi-spectral imaging is also inherently available for recently introduced PCD-CT. However, data on diagnostic accuracy of multi-spectral PCD-CT is currently lacking.

Being tested
Photon Counting Detector CT

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Photon Counting Detector CTDevice

    Photon counting detector CT scan with dose arbitrarily reduced compared to EID CT scan (e.g., half the dose of EID CT)

Study groups in NCT06281808
Study groupRoleWhat they receive
Photon Counting Detector CTExperimentalPCD CT
Receives: Device: Photon Counting Detector CT

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Image Quality PCD CT

    Likert scale based - 5 point Likert scale (0 = worst, 5 = best)

    Visual gradings of PCD-CT image quality. Image quality will be assessed by teams of experienced musculoskeletal radiologists. Images from consistent sets of intra-subject PCD-CT and EID-CT data will be presented to derive the primary outcome data, in particular using visual analog scales (Likert-Scales). Inter-reader reliability will be assessed.

    Measured: 2 years

  2. Diagnostic Accuracy PCD CT

    This will involve the calculation of sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy. The EID-CT image interpretation of the attending radiologists, as documented in the written report, will serve as reference standard against which the performance of PCD-CT will be compared. In cases with inconclusive written reports and image findings of EID-CT, a review committee consisting of experienced radiologists (e.g., other attending radiologists, chief of radiology) will be convened, and consensus reading including clinical correlation by consulting with the treating physicians and specialists involved in the patient's care will be done. Diagnostic confidence will be additionally analyzed for PCD-CT scans on a Likert-Scale. Inter-reader reliability will be assessed.

    Measured: 2 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Feb 2024
  2. Study start28 Jan 2024
  3. Primary completion1 Sep 2026 (estimated)
  4. Study completion31 Dec 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
200 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06281808
Sponsor's protocol ID
R490
Status last verified
Oct 2025
First submitted
5 Feb 2024
Last updated
2 Oct 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Photon Counting Detector CT in people with Diagnostic Imaging and Tomography, X Ray Computed, run by Reto Sutter, MD at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 2 Oct 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Image Quality PCD CT (time frame: 2 years). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Oct 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in