Trial summary

Bioprosthetic valves are usually made of biological tissue that are mounted to a frame and are designed to function similarly to a healthy natural valve. Edwards Magna Ease and Intuity Elite bioprosthetic valves have similar leaflets and mounting designs. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
CFD, Valve Heart Disease
What is being tested?
Computed Tomography, Magnetic Resonance Imaging
How many people
20 participants
Where
No sites listed yet
Study dates
1 Apr 2024to 1 Apr 2026
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: 20 informed and consented patients who undergo the Intuity Elite (n=10) and Magna EASE (n=10) valves will be prospectively enrolled. The patients will be evaluated at 3- and 12-months post valve replacement.

Who may be able to join

  • Male and female patients aged 18 years or over.
  • Patients diagnosed with aortic valve disease, and scheduled to undergo Edwards Magna Ease or Intuity Elite and free of exclusion criteria below.
  • The patient is willing and able to understand the Patient Information Sheet and provide written informed consent.
  • The patient must agree to comply with the study imaging protocol as required at prespecified times.

Who cannot join

  • Inability to provide valid informed consent.
  • Male and female patients aged < 18 years of age.
  • Contraindications for CT angiography: renal failure (Cr>250 μmol/L or eGFR<30 mL/min) due to the additional risk of contrast medium nephrotoxicity or allergy to iodine.
  • Women of childbearing age who have not had a hysterectomy and/or who may be breastfeeding.
  • History of cardiac pacing device insertion, or any other MRI incompatible device implants.

Trial locations and contacts

No sites are listed yet.

Saeed Mirsadraee, MD, Ph.D contact

02073528121

s.mirsadraee@rbht.nhs.uk

About this study

Official title: Comparing the In-vivo Haemodynamic and Biomechanical Performance of Rapid-deployment Edwards Intuity Elite System and Edwards Magna Ease Valve

Bioprosthetic valves are usually made of biological tissue that are mounted to a frame and are designed to function similarly to a healthy natural valve. Edwards Magna Ease and Intuity Elite bioprosthetic valves have similar leaflets and mounting designs. However, the valves are implanted in the patient in different ways (one is stitched to the wall of the left ventricular outflow tract, and the other is held in place by the radial force of the valve skirt). The study aims to understand in more detail how the different valves interact with the left ventricular outflow tract and aortic root.

Read the detailed description

The implantation of a bioprosthetic valve is the established surgical technique when replacing the aortic valve to treat various aortic valve diseases. Many different bioprosthetic valves are available. The design and implantation technique in each system would result in different interaction with the left ventricular outflow tract (LVOT) and the aortic root, leading to different flow profiles that may induce platelet aggregation and affect the long-term performance of the bioprosthesis and its durability. Additionally, complications such as valve thrombosis may occur. However, it is not currently clear which bioprostheses/patients are more prone to thrombosis or degradation of the valve. This study aims to develop fluid-structure interaction (FSI) models, which can model blood flow and wall/valve mechanics, using realistic patient-specific geometries and flow conditions which correlate with the true performance of the valve in the imaged patients, and to assess and compare such performances to understand the benefits and challenges with various bioprosthetic valves.

FSI models combine computational fluid mechanics (CFD) with structural wall mechanics modelling. This is an alternative approach that allows detailed assessment of flow patterns and estimation of wall shear stress and pressure within blood vessels, and therefore has been applied increasingly to gain better insights into the hemodynamics in cardiovascular diseases

Being tested
Computed Tomography, Magnetic Resonance Imaging
Keywords
Bioprosthesis
Medical subject headings
Heart Valve Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Computed Tomography, Magnetic Resonance ImagingDiagnostic test

    Computed Tomography, Magnetic Resonance Imaging

Study groups in NCT06306729
Study groupRoleWhat they receive
Standard ImplantationNot described
Receives: Diagnostic Test: Computed Tomography, Magnetic Resonance Imaging
Rapid DeploymentNot described
Receives: Diagnostic Test: Computed Tomography, Magnetic Resonance Imaging

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. blood flow velocities

    Blood flow velocities (cm/s) will be quantified for each bioprosthesis at 3 levels: subvalvular (LVOT and native annulus), transvalvular, the aortic root, and the proximal ascending aorta. Velocities more than 20cm/s will be taken as abnormal.

    Measured: 12 months

  2. Time average wall shear stress (TAWSS)

    TAWSS will be quantified for each bioprosthesis at 3 levels: subvalvular (LVOT, the aortic root, and the proximal ascending aorta. TAWSS under 0.5Pa is taken as low, 0.51-2.0 as moderately increased, >2.0 Pa as severely increased TAWSS.

    Measured: 12 months

Secondary outcomes (3)
  1. Patient's satisfaction

    A questionnaire will be designed to score valve-related clinical symptoms following the intervention.

    Measured: 12 months

  2. Evidence of major adverse cardiac and cerebrovascular events (MACCE)

    Evidence of MACCE (Stroke and myocardial infarction in the first 12 months post procedure)

    Measured: 12 months

  3. Mortality

    Evidence of mortality during the 12 months post procedure.

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Mar 2024
  2. Study start1 Apr 2024 (estimated)
  3. Primary completion1 Apr 2025 (estimated)
  4. Study completion1 Apr 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06306729
Sponsor's protocol ID
316308
Status last verified
Mar 2024
First submitted
12 Jan 2024
Last updated
12 Mar 2024
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of CFD and Valve Heart Disease, run by Royal Brompton & Harefield NHS Foundation Trust.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 12 Mar 2024. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Saeed Mirsadraee, MD, Ph.D (02073528121, s.mirsadraee@rbht.nhs.uk), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

blood flow velocities (time frame: 12 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 12 Mar 2024.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in