Evaluation of Leak-Free Bronchoscope Adapter to Limit Ventilated Air Volume Loss During Bronchoscopy

A study testing Leak-free bronchoscope adapter in people with Pulmonary Disease, run by Endeavor Health at 1 site in United States.

Withdrawn

Withdrawn. The study stopped before anyone enrolled.

Official record
Search all trials

Trial summary

The purpose of this research is to evaluate the ability of a new bronchoscope adapter called "leak-free adapter" to limit the amount of air leaking out to the operating room (OR) from the ventilator in intubated patients who undergo bronchoscopy. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Pulmonary Disease
What is being tested?
Leak-free bronchoscope adapter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
0 participants
Where
1 siteUnited States
Study dates
17 Jan 2024to Nov 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Participants who will be undergoing elective intubation for either a surgical or bronchoscopic procedure (diagnostic or therapeutic)
  • Both males and females
  • Adults 18 years and older

Who cannot join

  • Significant protocol deviation
  • Significant non-compliance with protocol or study requirements
  • An adverse event which requires discontinuation which results in the inability to continue to comply with study procedures.
  • Consent is withdrawn.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • NorthShore University HealthSystem

    Chicago, Illinois, 60201

Other trials in United States

About this study

Official title: Evaluation of Leak-free Bronchoscope Adapter to Limit Ventilated Air Volume Loss and Aerosolization From Intubated Patients Who Undergo Bronchoscopy

The purpose of this research is to evaluate the ability of a new bronchoscope adapter called "leak-free adapter" to limit the amount of air leaking out to the operating room (OR) from the ventilator in intubated patients who undergo bronchoscopy.

Read the detailed description

Bronchoscopy is a commonly performed procedure where a camera tipped device is used to look into a patient's lung. To perform bronchoscopy, a "standard commercial adapter" is connected to the ventilator tubing, which lets the doctors use the bronchoscope.The design of the "standard commercial adapter" can cause about 20% of air to escape from the ventilator to the OR. This leaked air causes two issues: first, this can lead to lower oxygen levels and can limit the amount of time your physician can perform bronchoscopy. Second, the leaked air can lead to the spread of harmful particles like anesthesia gas to the OR. These particles can harm the staff in the operating room or spread to other patients in the hospital.

This study will compare the benefit of the "standard commercial adapter" to the newly developed "leak-free adapter". The investigational procedure being studied here is repeating the bronchoscopy with the leak-free adapter. Outcomes (which measure the benefit of the new adapter) will be measured for each adapter independently. Bronchoscopy using both devices will be performed by the physician performing the procedure.

Being tested
Leak-free bronchoscope adapter
Keywords
Bronchoscope adapter
Medical subject headings
Lung Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Leak-free bronchoscope adapterDevice

    Bronchoscopy using both a standard adapter and a leak-free adapter will be performed.

Study groups in NCT06310577
Study groupRoleWhat they receive
Leak free bronchoscope adapterExperimentalAs a standard part of procedure, bronchoscopy will be performed using the "standard commercial adapter". Following the standard bronchoscope adapter use, leak-free bronchoscope adapter will be tested to compare the amount, and quality of air leaked between the"standard commercial adapter" and the "leak-free adapter.
Receives: Device: Leak-free bronchoscope adapter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of participants able to undergo bronchoscopic evaluation using the "leak-free adapter"

    Assessment of the capacity to complete the full bronchoscopic procedure using the "leak-free adapter" device.

    Measured: During the bronchoscopy procedure

  2. Heart rate (bpm)

    Prior to the initiation of the bronchoscopic procedure, the patient's will heart rate will be recorded. These values will be continuously monitored and recorded throughout the bronchoscopic procedure.

    Measured: Immediately before the procedure and during the procedure

  3. Blood pressure (mmHg)

    Prior to the initiation of the bronchoscopic procedure, the patient's blood pressure will be recorded. These values will be continuously monitored and recorded throughout the bronchoscopic procedure.

    Measured: Immediately before the procedure and during the procedure

  4. Oxygenation as measured by SpO2

    Quantification and comparison of patient oxygenation using the "leak-free bronchoscope adapter" vs. the "standard commercial adapter". A pulse oximeter will be used to measure the patient's oxygen saturation (SpO2). Prior to bronchoscopy, the patients circulating oxygen saturation will be recorded during 10 ventilated breaths. Upon initiation of bronchoscopy, the SpO2 level will be measured throughout the procedure.

    Measured: Immediately before the procedure and during the procedure

  5. Assessment of adverse events

    Any adverse events related to the leak-free adapter use will be evaluated.

    Measured: During the procedure and immediately after the procedure

Secondary outcomes (4)
  1. Evaluation of bronchoscope adapter tidal volume loss efficacy

    Quantification and comparison of the proportion of tidal volume delivered to a patient by the ventilator during bronchoscopy using the "leak-free bronchoscope adapter" vs. the "standard commercial adapter".

    Measured: During the bronchoscopy procedure

  2. Evaluation of bronchoscope adapter aerosolization efficacy

    Quantification and comparison of aerosolized gas delivered to the ambient environment by the ventilator during bronchoscopy using the "leak-free bronchoscope adapter" vs. the "standard commercial adapter".

    Measured: During the bronchoscopy procedure

  3. Peak airway pressure (cmH2O)

    Quantification and comparison of pulmonary pressure parameters by the ventilator during bronchoscopy. Peak airway pressure (cmH2O) will be obtained from ventilator during bronchoscopy using the "leak-free bronchoscope adapter" vs. the "standard commercial adapter".

    Measured: During the bronchoscopy procedure

  4. Dynamic compliance (mL/CmH2O)

    Quantification and comparison of pulmonary pressure parameters by the ventilator during bronchoscopy. Dynamic compliance (mL/CmH2O) will be obtained from ventilator during bronchoscopy using the "leak-free bronchoscope adapter" vs. the "standard commercial adapter".

    Measured: During the bronchoscopy procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Mar 2024
  2. Study start17 Jan 2024 (estimated)
  3. Primary completionNov 2026 (estimated)
  4. Study completionNov 2026 (estimated)

Why it stopped: No participants enrolled

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Self-controlled
Masking
None (open label)
Enrolment
0 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06310577
Sponsor's protocol ID
EH23-343
Status last verified
Dec 2025
First submitted
19 Feb 2024
Last updated
30 Dec 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Leak-free bronchoscope adapter in people with Pulmonary Disease, run by Endeavor Health at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: withdrawn, as of the sponsor's last update on 30 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was withdrawn before enrolling participants, so there are no results.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of participants able to undergo bronchoscopic evaluation using the "leak-free adapter" (time frame: During the bronchoscopy procedure). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Dec 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in