AzTrials
AzTrials

Radiotherapy Side EffectstentNCT06353724

Comparison Between the Effect of Using Conventional and Digital Oral Positional Radiation Stent

A study testing conventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planning and Digital positioning stent in people with Radiotherapy Side Effect, run by Tanta University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this clinical trial is to compare between the Effect of Using Conventional and Digital Oral Positional Radiation Stent on Healthy tissues, salivary PH. The main question it aims to answer are: Does the difference in manufacturing method affect on Healthy tissues, salivary PH. Read more about this study

Who is it for?
Ages 20 to 70 yearsHealthy volunteers can take part
Conditions the study is for
Radiotherapy Side Effect
What is being tested?
conventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planning and Digital positioning stent
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
16 participants
Where
1 siteEgypt
Study dates
14 Oct 2019to 1 Jan 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 70 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Limit of age was between 20 -40 years old.
  • Inter-arch distance ≥ 1.5 cm
  • Good oral hygiene.

Who cannot join

  • Patients with conditions that limited the construction of the stent (e.g. gross tumor block most of the oral cavity, sever limited mouth opening)
  • Patients with recurrent cancerous lesions.
  • Edentulous patients.
  • Previously radiotherapy for head and neck
  • Smoking.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Faculty of Dentistry

    Tanta, Gharbia Governorate, 31527

Other trials in Egypt

About this study

Official title: Comparison Between the Effect of Using Conventional and Digital Oral Positional Radiation Stent on Healthy Tissues, Salivary PH

The goal of this clinical trial is to compare between the Effect of Using Conventional and Digital Oral Positional Radiation Stent on Healthy tissues, salivary PH. The main question it aims to answer are: Does the difference in manufacturing method affect on Healthy tissues, salivary PH.

Participants will use radiation positioning stent during radiotherapy sessions Two groups will be compared

  • Group A: OPRS was constructed according to the conventional technique.
  • Group B: OPRS was constructed digitally using CAD /CAM technology. to evaluate Dosimetric analysis to quantify the radiation dose in OARs, PH of saliva measurement and Mucositis assessment.
Read the detailed description

This study will be a clinically prospective study that will include 16 patients with head and neck cancer. This study will be carried out at the Clinical Prosthodontics Department \& Clinical Oncology Department of Tanta University.

Informed consent will be obtained from all patients with maintenance of their privacy prior to inclusion in the study according to the guidelines on human research adopted by the Research Ethics Committee, Faculty of Dentistry, Tanta University.

Patient's evaluation:

All patients will be subjected to the following protocol:

Oral examination: Clinical dental evaluation, intraoral photography and mouth opening measurements

Grouping: The patients will be divided randomly into 2 groups (each group consists of 8 patients) according to the technique that will be used for construction:

First group: The OPRS will be constructed according to the conventional technique.27

Second group: The OPRS will be constructed digitally according to the following steps:

Intraoral scanning: It will be done using an intraoral scanner to generate three 3D images: the first of the superior arch, the second of the inferior arch, and the third of the maximum habitual intercuspation. Images will be compiled into a 3D file system.

Oral positioning radiation stent design: The compiled file will be exported into Exocad software, which is smart software for dental design on digital models, for stent design, and by using a virtual articulator.

3D printing: After optimizing the digital file, 3D printing will be performed. The oral positioning radiation stent will be printed using the 3D printer Resin Printing Material.

For both groups:

Insertion: making the necessary adjustment will be done.

RT techniques and dose distributions:

All patients will be referred to the RT department for IMRT planning. During the pre-irradiation simulation, the intraoral stents will be placed, and the patients will be immobilized by individual thermoplastic masks. A computed tomography scan will be conducted to determine the precise planning target volume (PTV); all patients will be scanned using the positional prosthesis once and without it.

Dosimetric analysis:

To quantify the radiation dose in the structures, the maxilla (area of the teeth), both parotid glands (ipsilateral and contralateral), the mandible, and the PTV will be defined and contoured in computed tomography pre-irradiation planning. The mean corresponding dose of each structure will be acquired using a dose-volume histogram.

All patients will complete the radiotherapy sessions using the positional radiation prosthesis together with the extra oral immobilization masks.

Mucositis assessment:

The severity of mucositis will be assessed weekly from the beginning of RT to the end of the treatment (mean time, 7 weeks). It will be scored in accordance with the classification criteria of the National Cancer Institute.

PH of saliva measurement:

A saliva sample will be collected from each patient to measure salivary PH by digital PH meter 19 before the beginning of radiotherapy, and the measurement will be continued weekly until the end of the treatment.

Being tested
conventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planning, Digital positioning stent
Keywords
Radiation, Positioning stent, Removable prosthesis
Medical subject headings
Radiation Injuries

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • conventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planningDevice

    Dosimetric analysis: the maxilla (area of the teeth), both parotid glands (ipsilateral and contralateral), the mandible, and the PTV were defined and contoured in computed tomography pre irradiation planning. The mean corresponding dose of each structure were acquired using a dose-volume histogram.

    All patients will complete the radiotherapy sessions using the positional radiation prosthesis.

    Mucositis assessment: The severity of mucositis will be assessed weekly from the beginning of RT to the end of the treatment (mean time, 7 weeks). It will be scored in accordance with the classification criteria of the National Cancer Institute.

    PH of saliva measurement: Collection of saliva sample were done from each patient to measure salivary PH by digital PH meter before beginning of radiotherapy and the measurement will be continued weekly till the end of the treatment.

  • Digital positioning stentDevice

    Digital positioning stent

Study groups in NCT06353724
Study groupRoleWhat they receive
conventional positioning stentPlacebo comparatorThe Oral positioning stent were constructed according to the conventional technique
Receives: Device: conventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planning
Digital positioning stentActive comparatorThe Oral positioning stent will be constructed digitally
Receives: Device: Digital positioning stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Dosimetric analysis

    The teeth away from the target site, both parotid glands and the maxilla, and OARs were defined and contoured in CT pre-irradiation planning using ECLIPSE software to each patient with the stent and without it and the mean corresponding dose of each structure was acquired using a dose volume histogram (DVH).

    Measured: 1 week

  2. PH of saliva measurement:

    Salivary PH was measured by digital PH meter before beginning of RT and the measurement was continued weekly throughout the treatment period till its end.

    Measured: 4 weeks

  3. Mucositis assessment:

    The severity of mucositis was assessed weekly from the beginning of RT to the end of the treatment at the RT department. The grading was scored in accordance with the Mucositis grading of National Cancer Institute-Common Terminology Criteria for Adverse Events (NCI-CTCAE), grading scores from 0-4 which 0 means better (None) and 4 means worse (Necrosis or deep ulceration; may include bleeding not induced by minor trauma or abrasion)

    Measured: 4 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Apr 2024
  2. Study start14 Oct 2019
  3. Primary completion1 Oct 2020
  4. Study completion1 Jan 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
16 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06353724
Sponsor's protocol ID
RP2218
Acronym
stent
Status last verified
Apr 2024
First submitted
20 Mar 2024
Last updated
9 Apr 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing conventional oral positioning stent were used during radiation planning and the PTV will be defined and contoured in computed tomography pre irradiation planning and Digital positioning stent in people with Radiotherapy Side Effect, run by Tanta University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Dosimetric analysis (time frame: 1 week). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Apr 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in