AzTrials
AzTrials

Vascular Access DevicesNCT06355466

Tunneled Hemodialysis Catheters as Permanent Vascular Access: Evaluating One-year Patency Rate and Affecting Factors

An observational study of Vascular Access Devices, run by Golestan University of Medical sciences at 1 site in Iran.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In this prospective cross-sectional study, patients with ESRD unfit for AVF/AVG were scheduled for a right or left trans-jugular tunneled catheter placement. All patients were asked about their catheters' function one year after its implantation and the presumed affecting factors on catheters' patency were evaluated. Read more about this study

Who is it for?
Any age
Conditions the study is for
Vascular Access Devices
How many people
156 participants
Where
1 siteIran
Study dates
9 Jan 2022to 28 Aug 2023
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: All patients who need continuous hemodialysis and are not eligible to AVF/AVG implantation were scheduled for trans-jugular, tunneled-catheter implantation and after one session of successful hemodialysis were followed one year later for their catheters' function.

Who may be able to join

  • ESRD on chronic hemodialysis Not eligible for AVF/AVG

Who cannot join

  • Non-consent of the patient Death Failure to follow up Opportunity for AVF/AVG implantation during the study Failure to implant trans-jugular catheter

Trial locations and contacts

1 site in 1 country.

Iran1 site
  • Golestan University of Medical Sciences, faculty of medicine

    Gorgan, Golestan Province, 4918936316

Other trials in Iran

About this study

Official title: Evaluation of Duration of the Long-term Hemodialysis Catheters Patency and Its Effecting Factors in Chronic Hemodialysis Patients in Golestan Province in 1400-1401

In this prospective cross-sectional study, patients with ESRD unfit for AVF/AVG were scheduled for a right or left trans-jugular tunneled catheter placement. All patients were asked about their catheters' function one year after its implantation and the presumed affecting factors on catheters' patency were evaluated.

Read the detailed description

In this prospective cross-sectional study, the population consisted of patients with end-stage renal failure who were undergoing chronic hemodialysis from 2021-2022 in Golestan province. Patients with end-stage renal failure who were candidates to start or continue dialysis through tunneled catheters as permanent access were included in the study.

According to the 2019 KDOQI guideline, all of the patients were excluded from AVF/ AVG implantation because of one or more of these reasons: heart failure, failed AVF/AVG with no remaining viable option for new AVF/AVG construction, absence of suitable artery/ vein for AVF or AVG construction, patient's preference despite understanding the superiority of AVF/AVG to catheters.

Written informed consent was obtained from all of the patients for conduction and publication of the study.

In all patients, the priority was to insert the catheter through the right jugular unless their right jugular vein was occluded in the preoperative ultrasound, or if it was not possible to pass the wire through the right jugular vein to the right atrium. In these patients, the left jugular vein was used as the insertion site. In some patients left side catheter insertion was not possible as well. These patients whose catheters were placed somewhere else were excluded from the study. In all cases, the proper location of the catheter tip -at the junction of the superior vena cava with the right atrium- was ensured using intraoperative fluoroscopy with a C-arm. For this purpose, catheters of a tip-to-cuff size of 19 and 23 were installed on the right and left side, respectively. For at least one post-implantation session, proper hemodialysis function of the catheter was ensured. All patients underwent surgery by the same vascular surgeon in a single secondary/teaching public center, and due to the restrictions rendered by economic sanctions, a single brand of catheter was used for all patients. A special questionnaire was utilized to record data on age, gender, underlying diseases (diabetes or high blood pressure), medications, and catheter location. All patients' catheter efficacy was re-evaluated one year later by referring to their hemodialysis center or by calling them, and the adequacy of their catheters was recorded to provide adequate flow for hemodialysis. The affecting factors on catheters' patency were evaluated and analysed using statistical software.

Keywords
Hemodialysis, Tunneled catheter, Patency, Antiplatelet

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. one year patency rate of hemodialysis catheters

    percent of catheters remained patent one year after their implantation

    Measured: one year

Secondary outcomes (5)
  1. one year patency rate of hemodialysis catheters in age subgroups

    percent of catheters remained patent one year after their implantation in age subgroups

    Measured: one year

  2. one year patency rate of hemodialysis catheters in diabetic patients

    percent of catheters remained patent one year after their implantation in diabetic patients

    Measured: one year

  3. one year patency rate of hemodialysis catheters in hypertensive patients

    percent of catheters remained patent one year after their implantation in hypertensive patients

    Measured: one year

  4. one year patency rate of hemodialysis catheters in patients on antiplatelet drugs

    percent of catheters remained patent one year after their implantation in patients on antiplatelet drugs

    Measured: one year

  5. one year patency rate of hemodialysis catheters in sex subgroups

    percent of catheters remained patent one year after their implantation in sex subgroups

    Measured: one year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Apr 2024
  2. Study start9 Jan 2022
  3. Primary completion11 Aug 2023
  4. Study completion28 Aug 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
156 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06355466
Sponsor's protocol ID
51-112334
Status last verified
Apr 2024
First submitted
23 Dec 2023
Last updated
9 Apr 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Thurlow JS, Joshi M, Yan G, Norris KC, Agodoa LY, Yuan CM, Nee R. Global Epidemiology of End-Stage Kidney Disease and Disparities in Kidney Replacement Therapy. Am J Nephrol. 2021;52(2):98-107. doi: 10.1159/000514550. Epub 2021 Mar 22.

    PubMed 33752206
  • Ikizler TA, Cuppari L. The 2020 Updated KDOQI Clinical Practice Guidelines for Nutrition in Chronic Kidney Disease. Blood Purif. 2021;50(4-5):667-671. doi: 10.1159/000513698. Epub 2021 Mar 2.

    PubMed 33652433
  • El Khudari H, Ozen M, Kowalczyk B, Bassuner J, Almehmi A. Hemodialysis Catheters: Update on Types, Outcomes, Designs and Complications. Semin Intervent Radiol. 2022 Feb 18;39(1):90-102. doi: 10.1055/s-0042-1742346. eCollection 2022 Feb.

    PubMed 35210738
  • Boubes K, Shaikh A, Alsauskas Z, Dwyer A. New Directions in Ensuring Catheter Safety. Adv Chronic Kidney Dis. 2020 May;27(3):228-235. doi: 10.1053/j.ackd.2020.02.004.

    PubMed 32891307
  • Obialo CI, Conner AC, Lebon LF. Maintaining patency of tunneled hemodialysis catheters--efficacy of aspirin compared to warfarin. Scand J Urol Nephrol. 2003;37(2):172-6. doi: 10.1080/00365590310008938.

    PubMed 12745728
  • Yaxley J. Haemodialysis catheters - a review of design and function. Expert Rev Med Devices. 2022 Oct;19(10):757-762. doi: 10.1080/17434440.2022.2132148. Epub 2022 Nov 3.

    PubMed 36251438
  • Kumbar L, Yee J. Current Concepts in Hemodialysis Vascular Access Infections. Adv Chronic Kidney Dis. 2019 Jan;26(1):16-22. doi: 10.1053/j.ackd.2018.10.005.

    PubMed 30876612
  • Braet P, Van Holsbeeck A, Buyck PJ, Laenen A, Claes K, De Vusser K, Maleux G. Comparison of Clinical Performance Between Two Types of Symmetric-Tip Hemodialysis Catheters: A Single-Centre, Randomized Trial. Cardiovasc Intervent Radiol. 2023 Aug;46(8):983-990. doi: 10.1007/s00270-023-03476-0. Epub 2023 Jun 13.

    PubMed 37311842
  • Besarab A, Pandey R. Catheter management in hemodialysis patients: delivering adequate flow. Clin J Am Soc Nephrol. 2011 Jan;6(1):227-34. doi: 10.2215/CJN.04840610. Epub 2010 Nov 29.

    PubMed 21115628
  • Agha R, Abdall-Razak A, Crossley E, Dowlut N, Iosifidis C, Mathew G; STROCSS Group. STROCSS 2019 Guideline: Strengthening the reporting of cohort studies in surgery. Int J Surg. 2019 Dec;72:156-165. doi: 10.1016/j.ijsu.2019.11.002. Epub 2019 Nov 6.

    PubMed 31704426
  • Coker MA, Black JR, Li Y, Varma R, Almehmi A, Abdel Aal AK, Gunn AJ. An analysis of potential predictors of tunneled hemodialysis catheter infection or dysfunction. J Vasc Access. 2019 Jul;20(4):380-385. doi: 10.1177/1129729818809669. Epub 2018 Nov 13.

    PubMed 30421638
  • Xiong Y, Yu Y, Yang Y, Wang L, Shi P, Deng Y, Li Y, Fu P. Impacts of age, diabetes, gender, and access type on costs associated with vascular access among Chinese patients on hemodialysis. Int J Artif Organs. 2021 May;44(5):302-309. doi: 10.1177/0391398820962112. Epub 2020 Oct 4.

    PubMed 33016167
  • Valliant AM, Chaudhry MK, Yevzlin AS, Astor B, Chan MR. Tunneled dialysis catheter exchange with fibrin sheath disruption is not associated with increased rate of bacteremia. J Vasc Access. 2015 Jan-Feb;16(1):52-6. doi: 10.5301/jva.5000301. Epub 2014 Sep 2.

    PubMed 25198820
  • Shi M, Cui T, Ma L, Zhou L, Fu P. Catheter Failure and Mortality in Hemodialysis Patients with Tunneled Cuffed Venous Catheters in a Single Center. Blood Purif. 2017;43(4):321-326. doi: 10.1159/000455062. Epub 2017 Jan 31.

    PubMed 28135701
  • Shingarev R, Barker-Finkel J, Allon M. Natural history of tunneled dialysis catheters placed for hemodialysis initiation. J Vasc Interv Radiol. 2013 Sep;24(9):1289-94. doi: 10.1016/j.jvir.2013.05.034. Epub 2013 Jul 18.

    PubMed 23871694

Questions about this trial

What is this clinical trial studying?

An observational study of Vascular Access Devices, run by Golestan University of Medical sciences at 1 site in Iran.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Iran. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

one year patency rate of hemodialysis catheters (time frame: one year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06355466, which also lists 22 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Apr 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in