Aortic Aneurysm, ThoracoabdominalSPHERENCT06358248

Standardized Physician-modified Fenestrated Endograft Registry

An observational study of Aortic Aneurysm, Thoracoabdominal and Aortic Diseases, run by University Hospital Padova at 1 site in Italy.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Multicenter retrospective study including all consecutive patients treated by PMEG using a standard modification technique of Valiant Captivia (Medtronic, Minneapolis, MN-USA). Read more about this study

Who is it for?
Ages 18 to 100 years
What is being tested?
Physician-modification of Valiant Captivia Endograft (Medtronic, Minneapolis, MN-USA).
Type of treatment
Medical device
How many people
50 participants
Where
1 siteItaly
Study dates
1 Oct 2023to 1 Oct 2033
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 100 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: All patients who underwent e PMEG with 4-fenestration procedure for the treatment of a short neck AAA, juxta/para-renal AAA, and type IV thoracoabdominal aneurysm (TAAA).

Who may be able to join

  • Complex AAA (including short-neck AAA, JRAA, PRAA, extent IV TAAA)
  • Haemodynamic stability
  • Anatomical feasibility is based on the presence of a proximal aortic neck above the mid celiac trunk of ≥25 mm in length and between 18 mm and 35 mm in diameter; the neck needs to be "healthy" with no parietal calcifications or thrombus with a cylindrical shape. The visceral aorta is required to be no larger than 40 mm in maximum diameter.

Who cannot join

  • Extent I-III TAAA
  • Hemorrhagic shock

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Michele Piazza, MD contact

0498218154

michele.piazza@unipd.it

Italy1 site, 1 recruiting
  • Vascular and Endovascular Clinic - Padova University

    Padova, 35020

    Michele Piazza, Pr, 3498644688, michele.piazza@unipd.it

    Recruiting

Other trials in Italy

About this study

Multicenter retrospective study including all consecutive patients treated by PMEG using a standard modification technique of Valiant Captivia (Medtronic, Minneapolis, MN-USA).

Read the detailed description

INTRODUCTION

Abdominal aortic aneurysms (AAA) without an adequate proximal neck length for safe sealing and fixation with a standard EVAR may benefit from complex endovascular repair. The most common are short neck AAA, juxta/para-renal AAA, and type IV thoracoabdominal aneurysm (TAAA), where incorporation of renal and visceral vessels is required to obtain an adequate proximal sealing. Several endovascular options are available, with the most effective being represented by incorporation of target vessels by custom-made or off-the-shelf fenestrated/branched endografts.

Custom-made devices have shown excellent early and long-term outcomes, but due to manufacturing time (up to three months), they can be used only for elective cases. In urgent cases, readily available off-the-shelf devices can be used, but their anatomical feasibility is not exhaustive, and may require long segment of aortic coverage above the celiac trunk. Parallel aortic grafts with chimneys or periscopes have been proposed as a timely alternative; however, gutter endoleaks and lack of proximal sealing are serious concerns for these techniques, especially for those cases where more than two target vessels need to be incorporated.

In patients presenting with large aneurysm, symptomatic, or requiring urgent repair, the use of physician-modified endograft (PMEG) represents a valid option. It allows for a rapid customization of a standard abdominal or thoracic device with the creation of fenestrations, scallops or branches, based on patient aneurysm anatomical extent and target vessel position.

However, these techniques demand high level of skills and experience; a recent review showed also that in the literature there is an extreme variability on indication to treatment, type of aneurysm and extension, type of graft, and method of modification, thus limiting the possibility to adequately analyze outcomes or drive comparison between different techniques.

Here the investigators describe an initial experience on safety and feasibility of a standardized approach with PMEG, based on specific anatomical selection criteria, measurement method and a standard technique of modification, using the Valiant Captivia (Medtronic, Minneapolis, MN-USA) thoracic endograft.

BACKGROUND AND PRELIMINARY DATA

The vast majority of the literature on PMEG is based on the Cook platform. Recently Chait et al. reported the long term outcomes of more than 150 Cook PMEGs, with excellent results in terms of early mortality, freedom from aortic-related mortality, and target instability, especially for complex AAA compared to TAAA.

There is only a single experience using Valiant Captivia PMEG Valiant in the version without free-flow. In this experience the authors reported 18 cases; after complete unsheathing, the graft was introduced in a sterile aortic 3D model for precise fenestration allocation and then re-sheathed. The investigators think that leaving the graft on its device may reduce the risk of infection, reducing manipulation and contact with other materials, as the the printed aortic model. The other two case reports using the Valiant platform for the treatment of the paravisceral segment are from Gibello et al., that used a Valiant Navion graft, and Joseph et al., that applied mini-cuff-augmented fenestration using Valiant Captivia.

STANDARDIZED DEVICE MODIFICATION

The graft is modified on a sterile back-table in a hybrid operating room, while the patient is prepared for general anesthesia. A Valiant Captivia thoracic graft with free-flow (either with tubular or tapered shape) is fully deployed without releasing the free-flow, that is maintained retained on its tip. After that, a vertical dotted line is drawn to mark the graft anterior 0° degree, and fabric holes are performed with ophthalmologic cautery in the desired position, taking care of not having graft struts within the fenestrations. The fenestrations need to be nicely round, ideally 6x6 mm for the renals and 8x8 mm for superior mesenteric artery (SMA) and celiac trunk (CT), and are reinforced with the tip of a 0.018 guidewire (V-18, Boston Scientific, Marlborough, Massachusetts-USA) through a continuous 5-0 non-adsorbable locking suture (Ti-cron, Medtronic, Minneapolis, Minnesota-USA).

A posterior constraining wire is created to temporarily reduce the diameter of the graft by 20-30%, in order to allow partial rotation during the deployment phase. The back of a 0.018'' guidewire is routed on the posterior aspect of the graft passing within the external suture of the struts, thus not requiring fabric puncture; the prolene used to reduce the diameter are tied around the stent struts and subsequently looped to the posterior wire. The four "8" markers on the top of the graft are carefully removed with a scalpel; one of these is modified as an "S" and re-sutured on the anterior aspect at 0 degree position, with a 5-0 prolene continuous suture. This "S" marker will allow anteroposterior graft orientation. Finally, the graft is re-sheathed with help of vessel loop.

FOLLOW-UP

A postoperative CTA is required within 30 days. Further follow-up follow-up is left to each center, but ideally includes imaging follow-up at 6, 12, 24 months and yearly thereafter.

Being tested
Physician-modification of Valiant Captivia Endograft (Medtronic, Minneapolis, MN-USA).
Keywords
Aortic Aneurysm, Thoracoabdominal Aneurysm, Endovascular aortic repair
Medical subject headings
Aortic Aneurysm, Thoracoabdominal, Aortic Diseases, Aortic Aneurysm

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Physician-modification of Valiant Captivia Endograft (Medtronic, Minneapolis, MN-USA).Device

    On a sterile back-table a Valiant Captivia thoracic graft is deployed. A dotted line is drawn to mark the graft anterior 0° degree, and fabric holes are performed with cautery in the desired position. The fenestrations need to be 6x6 mm for the renals and 8x8 mm for superior mesenteric artery (SMA) and celiac trunk (CT), and are reinforced with the tip of a 0.018 guidewire through a continuous 5-0 locking suture.

    A posterior constraining wire is created to reduce the diameter of the graft by 20-30%, in order to allow rotation during the deployment phase. The four "8" markers on the top of the graft are carefully removed with a scalpel; one of these is modified as an "S" and re-sutured on the anterior aspect at 0 degree position, with a 5-0 prolene continuous suture. This "S" marker will allow anteroposterior graft orientation. Finally, the graft is re-sheathed and deployed.

Study groups in NCT06358248
Study groupRoleWhat they receive
Patients treatedAll patients treated with 4-fen PMEG endograft
Receives: Device: Physician-modification of Valiant Captivia Endograft (Medtronic, Minneapolis, MN-USA).

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Technical success

    Number of participants who underwent a successful deployment of the endograft and stenting of the 4 visceral vessels

    Measured: Intra-operative

  2. Freedom from target vessel instability

    Number of participants who experience any occlusion, endoleak, aneurysm rupture, stent restenosis needing a re-intervention

    Measured: 5 years

  3. Freedom from endograft instability

    Number of participants who show absence of endoleak, aneurysm rupture, endograft migration

    Measured: 5 years

Secondary outcomes (2)
  1. Early (30-days) Major Adverse Event (MAE)

    Any early (30-days) Major Adverse Event

    Measured: 5 years

  2. Aneurysm sac dynamics

    Number of participants who experience aneurysm sac diameter change during follow-up

    Measured: 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Apr 2024
  2. Study start1 Oct 2023
  3. Primary completion1 Oct 2028 (estimated)
  4. Study completion1 Oct 2033 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Retrospective
Enrolment
50 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06358248
Sponsor's protocol ID
SPHERE
Acronym
SPHERE
Status last verified
Apr 2024
First submitted
7 Apr 2024
Last updated
16 Apr 2024
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

An observational study of Aortic Aneurysm, Thoracoabdominal and Aortic Diseases, run by University Hospital Padova at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 16 Apr 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Michele Piazza, MD (0498218154, michele.piazza@unipd.it), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Technical success (time frame: Intra-operative). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Apr 2024.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in