Dental ImplantNCT06404385
Accuracy of Static Computer-assisted Implant Surgery in Distal Free-end Scenarios
A study testing Static computer-assisted guided surgery with analogic guide and Static computer-assisted guided surgery with CAD-CAM surgical guide in people with Dental Implant and Computer-assisted, run by University of Valencia at 1 site in Spain.
Trial summary
Technological advances have influenced the approach to implant treatment. One of the fields presently experiencing rapid development is static computer-assisted guided surgery (sCAIS), which allows transfer of the virtual implant planning to the mouth of the patient, based on the use of a surgical guide. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Dental Implant, Computer-assisted
- What is being tested?
- Static computer-assisted guided surgery with analogic guide and Static computer-assisted guided surgery with CAD-CAM surgical guide
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 27 participants
- Where
- 1 siteSpain
- Study dates
- 11 Sep 2012to 17 Dec 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Indication of fixed prosthesis over at least two consecutive implants.
- Sufficient residual crest for placing at least two implants 4.1 mm in diameter and 8 mm in length.
- Mature bone and healthy soft tissues.
- Implants placed via fully guided surgery.
- Age > 18 years.
- Good general health.
Show all 10Show fewer
- Non-smokers or smokers of < 10 cigarettes/day (pipe smokers excluded).
- Oral hygiene index < 3 and bleeding index < 25%.
- Pre- and post- CBCT scan for analysis of accuracy.
- Periapical radiographs at loading and after one year.
Who cannot join
- Contraindications to implant therapy
- Locations with acute infection.
- Pregnant or nursing women.
- Lack of follow-up.
Trial locations and contacts
1 site in 1 country.
Spain1 site
University of Valencia. Faculty of Medecine and Dentistry. CLINICA ODONTOLOGICA
Valencia, Valencia, 46010
About this study
Official title: Prospective Clinical Study on the Accuracy of Static Computer-assisted Implant Surgery in Patients Rehabilitated With Distal Free-end Implants. Conventional Versus CAD-CAM Surgical Guides
Technological advances have influenced the approach to implant treatment. One of the fields presently experiencing rapid development is static computer-assisted guided surgery (sCAIS), which allows transfer of the virtual implant planning to the mouth of the patient, based on the use of a surgical guide. In sCAIS there is a deviation between the virtually planned implant position and the actual position of the implant placed during surgery. A recent review analyzed only fully guided implants and recorded a mean coronal horizontal deviation (CHD) of 1.12 mm (standard deviation [SD] = 0.08), a mean apical horizontal deviation (AHD) of 1.41 mm (SD = 0.1), a mean vertical deviation (VD) of 0.12 mm (SD = 0.23), and a mean angular deviation (AD) of 3.58º (SD = 0.2).
The aim of the present study was to compare the accuracy of CAD-CAM and conventional guides in candidates for distal free-end implant treatment, and to analyze the effects of possible confounding factors inherent to the patient or the surgical technique employed.A prospective, controlled and blinded quasi-experimental study was carried out involving 27 patients with 76 implants distributed into two groups according to the surgical guide manufacturing approach used: conventional (control group [CG]) or CAD-CAM (test group [TG]). The implants were planned virtually with the planning software, and the surgical guides were manufactured. Fully guided implant placement was carried out, and the deviations were measured along with other secondary variables as potential confounding factors.
Read the detailed description
Planning of the implants is made in the ideal prosthetic position based on a previous CAD-CAM (computer aided design - computer aided manufacturing) wax-up. sCAIS facilitates correct prosthetic emergence and therefore contributes to secure optimum esthetic and biological outcomes, affording long-term stability of the soft and hard tissues.
These surgical guides can be manufactured using CAD-CAM or conventional technologies in the laboratory, employing drilling machines or mechanical positioners. In the case of the conventional guide manufactured in the laboratory, the technician creates a radiological guide that is then converted into a surgical guide - the whole process being analogic, except for planning of the implants. At present, and with the development of digital workflows, CAD-CAM procedures are used for both the design and manufacture of the surgical guide, using different processes. This simplifies the workflow, which can reduce the costs of smaller rehabilitations.
Clinical studies on accuracy published in the literature are heterogeneous, with differences in the systems used, the surgical technique, the type of surgical guide support or the type of edentulism involved.These data justify further research in humans, focusing on fully sCAIS, in order to reduce heterogeneity. Furthermore, a review of the literature revealed a lack of clinical publications on the accuracy of CAD-CAM surgical guides compared to conventional guides. Therefore, the aim of the present study was to compare the accuracy of CAD-CAM and conventional guides in candidates for distal free-end implant treatment, and to analyze the effects of possible confounding factors inherent to the patient or the surgical technique employed. Intra- and postoperative complications of the surgical technique were also evaluated, as well as implant success and peri-implant marginal bone loss. Hence, the null hypothesis of the study was the absence of any difference in accuracy between both guides.
A prospective, controlled, examiner- and statistician-blinded, parallel-arm quasi-experimental study was carried out at the University of Valencia (Valencia, Spain). Two groups were established according to the surgical guide design involved: conventional (control group [CG]) or CAD-CAM (test group [TG]).
- Conditions
- Dental Implant, Computer-assisted
- Being tested
- Static computer-assisted guided surgery with analogic guide, Static computer-assisted guided surgery with CAD-CAM surgical guide
- Keywords
- accuracy, computer-assisted surgery, computer-aided design, analogic, dental implants
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Static computer-assisted guided surgery with analogic guideProcedure or surgery
Also called Conventional laboratory surgical guide, gonyX®
coDiagnostix9® planning software
Static computer-assisted guided surgery with CAD-CAM surgical guideProcedure or surgery
Also called CAD-CAM surgical guide
coDiagnostix9® planning software
| Study group | Role | What they receive |
|---|---|---|
| Conventional surgical guide | Active comparator | Implants (Straumann®) placed with an analogic laboratory surgical guide Receives: Procedure: Static computer-assisted guided surgery with analogic guide |
| Computer aided design - computer aided manufacturing (CAD-CAM) surgical guide | Experimental | Implants (Straumann®) placed with static computer-assisted implant surgery Receives: Procedure: Static computer-assisted guided surgery with CAD-CAM surgical guide |
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy in implants: vertical, apical and coronal horizontal deviations
New CBCT scans were obtained in all patients after implant placement . The coDiagnostix9® application was used to match the pre- and postoperative CBCT images and to compare the axis positions of the planned and placed implants. The vertical, apical and coronal horizontal deviations in millimeters (VD, AHD and CHD), were recorded between the long axis of the virtual planned and actual placed implant. Measured in millimeters
Measured: 1 week post-operative
Accuracy in implants: angular deviation
New CBCT scans were obtained in all patients after implant placement . The coDiagnostix9® application was used to match the pre- and postoperative CBCT images and to compare the axis positions of the planned and placed implants. The angular deviation in degrees (AD), was recorded between the long axis of the virtual planned and actual placed implant. Measured in degrees.
Measured: 1 weel post-operatiive
Secondary outcomes (4)
Intraoperative complications
Surgical guide fitting, retention, drill access, guide fracture, I
Measured: Intra-operative
Postoperative complications
Infection, bleeding, edema, neurological alterations, pain, swelling
Measured: One month after implant placement
Implant success
Success is defined as no permanent peri implant radiographic translucency, no sign of peri-implant infection with putrid secretion, absence of persistent pain, dysesthesia, and/or foreign-body feeling
Measured: One year of implant loading
Peri-implant marginal bone loss
Radiographic assessment of the marginal bone loss around the implants
Measured: One year of implant loading
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 May 2024
- Study start11 Sep 2012
- Primary completion17 Dec 2019
- Study completion17 Dec 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (11)Papers the sponsor has linked to this study.
- Other trials for Dental ImplantStudies of the same condition, open and under way.
- More trials run by University of ValenciaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Non-randomised
- Intervention model
- Parallel groups
- Model description
- A prospective, controlled, examiner- and statistician-blinded, parallel-arm quasi-experimental study
- Masking
- Triple blind
- Who is masked
- Participant, Investigator, Outcomes assessor
- Enrolment
- 27 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Valencia
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Berta García Mira, University of Valencia
- Investigators
- MIGUEL PEÑARROCHA-DIAGO, Phd, DDS, Study director, University of Valencia
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06404385
- Sponsor's protocol ID
- H20190402125847
- Status last verified
- Aug 2025
- First submitted
- 29 Apr 2024
- Last updated
- 5 Sep 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: Patients' personal data will not be published, however, the results of the scientific study will be published in a scientific dental journal.
Publications
Balaguer-Marti JC, Canet-Lopez A, Penarrocha-Diago M, Romeo-Rubio M, Penarrocha-Diago M, Garcia-Mira B. Influence of Splint Support on the Precision of Static Totally Guided Dental Implant Surgery: A Systematic Review and Network Meta-analysis. Int J Oral Maxillofac Implants. 2023 Jan-Feb;38(1):157-168. doi: 10.11607/jomi.9796.
PubMed 37099571Bover-Ramos F, Vina-Almunia J, Cervera-Ballester J, Penarrocha-Diago M, Garcia-Mira B. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies. Int J Oral Maxillofac Implants. 2018 January/February;33(1):101-115. doi: 10.11607/jomi.5556. Epub 2017 Jun 20.
PubMed 28632253Chen X, Yang Z, Wang Y, Fu G. Fixation Pins Increase the Accuracy of Implant Surgery in Free-End Models: An In Vitro Study. J Oral Maxillofac Surg. 2023 May;81(5):593-601. doi: 10.1016/j.joms.2022.12.017. Epub 2023 Jan 28.
PubMed 36716792El Kholy K, Lazarin R, Janner SFM, Faerber K, Buser R, Buser D. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery. Clin Oral Implants Res. 2019 Nov;30(11):1067-1075. doi: 10.1111/clr.13520. Epub 2019 Aug 20.
PubMed 31381178El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 2019 Feb;21(1):101-107. doi: 10.1111/cid.12705. Epub 2018 Dec 27.
PubMed 30589502Kessler A, Le V, Folwaczny M. Influence of the tooth position, guided sleeve height, supporting length, manufacturing methods, and resin E-modulus on the in vitro accuracy of surgical implant guides in a free-end situation. Clin Oral Implants Res. 2021 Sep;32(9):1097-1104. doi: 10.1111/clr.13804. Epub 2021 Jul 17.
PubMed 34218450Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FR, Makvandi P. 3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications. Acta Biomater. 2021 Mar 1;122:26-49. doi: 10.1016/j.actbio.2020.12.044. Epub 2020 Dec 26.
PubMed 33359299Le V, Kessler A, Folwaczny M. Influence of DLP and SLA printer technology on the accuracy of surgical guides for implant dentistry in free-end situations. Int J Comput Dent. 2023 Sep 26;26(3):217-226. doi: 10.3290/j.ijcd.b3774115.
PubMed 36625374Matta RE, Bergauer B, Adler W, Wichmann M, Nickenig HJ. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J Craniomaxillofac Surg. 2017 Jun;45(6):804-808. doi: 10.1016/j.jcms.2017.02.015. Epub 2017 Feb 20.
PubMed 28363503Putra RH, Yoda N, Astuti ER, Sasaki K. The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis. J Prosthodont Res. 2022 Jan 11;66(1):29-39. doi: 10.2186/jpr.JPR_D_20_00184. Epub 2021 Jan 26.
PubMed 33504723Berta GM, Luigi C, Miguel PD, Carlos BJ. Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides. Clin Oral Implants Res. 2025 Mar;36(3):314-324. doi: 10.1111/clr.14384. Epub 2024 Nov 23.
PubMed 39578942
Study at a glance
From the registry record, last updated by the sponsor on 5 Sep 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Clinical Study on the Accuracy of Static Computer-assisted Implant Surgery in Patients Rehabilitated With Distal Free-end Implants. Conventional Versus CAD-CAM Surgical Guides
- ClinicalTrials.gov ID
- NCT06404385
- Acronym / sponsor ID
- H20190402125847
- Conditions
- Dental Implant, Computer-assisted
- Keywords
- accuracy, computer-assisted surgery, computer-aided design, analogic, dental implants
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 27 participants (actual)
- Lead sponsor
- University of ValenciaUniversity, hospital or other
- Study start
- 11 Sep 2012 (actual)
- Primary completion
- 17 Dec 2019 (actual)
- Study completion
- 17 Dec 2019 (actual)
- First posted
- 8 May 2024 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Technological advances have influenced the approach to implant treatment. One of the fields presently experiencing rapid development is static computer-assisted guided surgery (sCAIS), which allows transfer of the virtual implant planning to the mouth of the patient, based on the use of a surgical guide. In sCAIS there is a deviation between the virtually planned implant position and the actual position of the implant placed during surgery. A recent review analyzed only fully guided implants and recorded a mean coronal horizontal deviation (CHD) of 1.12 mm (standard deviation [SD] = 0.08), a mean apical horizontal deviation (AHD) of 1.41 mm (SD = 0.1), a mean vertical deviation (VD) of 0.12 mm (SD = 0.23), and a mean angular deviation (AD) of 3.58º (SD = 0.2).
The aim of the present study was to compare the accuracy of CAD-CAM and conventional guides in candidates for distal free-end implant treatment, and to analyze the effects of possible confounding factors inherent to the patient or the surgical technique employed.A prospective, controlled and blinded quasi-experimental study was carried out involving 27 patients with 76 implants distributed into two groups according to the surgical guide manufacturing approach used: conventional (control group [CG]) or CAD-CAM (test group [TG]). The implants were planned virtually with the planning software, and the surgical guides were manufactured. Fully guided implant placement was carried out, and the deviations were measured along with other secondary variables as potential confounding factors.
Detailed description
Planning of the implants is made in the ideal prosthetic position based on a previous CAD-CAM (computer aided design - computer aided manufacturing) wax-up. sCAIS facilitates correct prosthetic emergence and therefore contributes to secure optimum esthetic and biological outcomes, affording long-term stability of the soft and hard tissues.
These surgical guides can be manufactured using CAD-CAM or conventional technologies in the laboratory, employing drilling machines or mechanical positioners. In the case of the conventional guide manufactured in the laboratory, the technician creates a radiological guide that is then converted into a surgical guide - the whole process being analogic, except for planning of the implants. At present, and with the development of digital workflows, CAD-CAM procedures are used for both the design and manufacture of the surgical guide, using different processes. This simplifies the workflow, which can reduce the costs of smaller rehabilitations.
Clinical studies on accuracy published in the literature are heterogeneous, with differences in the systems used, the surgical technique, the type of surgical guide support or the type of edentulism involved.These data justify further research in humans, focusing on fully sCAIS, in order to reduce heterogeneity. Furthermore, a review of the literature revealed a lack of clinical publications on the accuracy of CAD-CAM surgical guides compared to conventional guides. Therefore, the aim of the present study was to compare the accuracy of CAD-CAM and conventional guides in candidates for distal free-end implant treatment, and to analyze the effects of possible confounding factors inherent to the patient or the surgical technique employed. Intra- and postoperative complications of the surgical technique were also evaluated, as well as implant success and peri-implant marginal bone loss. Hence, the null hypothesis of the study was the absence of any difference in accuracy between both guides.
A prospective, controlled, examiner- and statistician-blinded, parallel-arm quasi-experimental study was carried out at the University of Valencia (Valencia, Spain). Two groups were established according to the surgical guide design involved: conventional (control group [CG]) or CAD-CAM (test group [TG]).
Study design
- Primary purpose
- Other
- Allocation
- Non-randomised
- Intervention model
- Parallel groups
- Masking
- Triple blind (participant, investigator, outcomes assessor)
- Number of arms
- 2
- Model description
- A prospective, controlled, examiner- and statistician-blinded, parallel-arm quasi-experimental study
| Arm | Type | Receives |
|---|---|---|
| Conventional surgical guide | Active comparator | Procedure: Static computer-assisted guided surgery with analogic guideImplants (Straumann®) placed with an analogic laboratory surgical guide |
| Computer aided design - computer aided manufacturing (CAD-CAM) surgical guide | Experimental | Procedure: Static computer-assisted guided surgery with CAD-CAM surgical guideImplants (Straumann®) placed with static computer-assisted implant surgery |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (10 listed)
- Indication of fixed prosthesis over at least two consecutive implants.
- Sufficient residual crest for placing at least two implants 4.1 mm in diameter and 8 mm in length.
- Mature bone and healthy soft tissues.
- Implants placed via fully guided surgery.
- Age > 18 years.
Key exclusion criteria (4 listed)
- Contraindications to implant therapy
- Locations with acute infection.
- Pregnant or nursing women.
- Lack of follow-up.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Static computer-assisted guided surgery with analogic guideAlso: Conventional laboratory surgical guide, gonyX®coDiagnostix9® planning software | Procedure or surgery | Conventional surgical guide |
| Static computer-assisted guided surgery with CAD-CAM surgical guideAlso: CAD-CAM surgical guidecoDiagnostix9® planning software | Procedure or surgery | Computer aided design - computer aided manufacturing (CAD-CAM) surgical guide |
Primary outcome
Accuracy in implants: vertical, apical and coronal horizontal deviations
Time frame: 1 week post-operative
New CBCT scans were obtained in all patients after implant placement . The coDiagnostix9® application was used to match the pre- and postoperative CBCT images and to compare the axis positions of the planned and placed implants. The vertical, apical and coronal horizontal deviations in millimeters (VD, AHD and CHD), were recorded between the long axis of the virtual planned and actual placed implant. Measured in millimeters
Accuracy in implants: angular deviation
Time frame: 1 weel post-operatiive
New CBCT scans were obtained in all patients after implant placement . The coDiagnostix9® application was used to match the pre- and postoperative CBCT images and to compare the axis positions of the planned and placed implants. The angular deviation in degrees (AD), was recorded between the long axis of the virtual planned and actual placed implant. Measured in degrees.
4 secondary outcomes
Intraoperative complications
Time frame: Intra-operative
Postoperative complications
Time frame: One month after implant placement
Implant success
Time frame: One year of implant loading
Peri-implant marginal bone loss
Time frame: One year of implant loading
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Sep 2025.
- Background: PubMed 37099571Balaguer-Marti JC, Canet-Lopez A, Penarrocha-Diago M, Romeo-Rubio M, Penarrocha-Diago M, Garcia-Mira B. Influence of Splint Support on the Precision of Static Totally Guided Dental Implant Surgery: A Systematic Review and Network Meta-analysis. Int J Oral Maxillofac Implants. 2023 Jan-Feb;38(1):157-168. doi: 10.11607/jomi.9796.
- Background: PubMed 28632253Bover-Ramos F, Vina-Almunia J, Cervera-Ballester J, Penarrocha-Diago M, Garcia-Mira B. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies. Int J Oral Maxillofac Implants. 2018 January/February;33(1):101-115. doi: 10.11607/jomi.5556. Epub 2017 Jun 20.
- Background: PubMed 36716792Chen X, Yang Z, Wang Y, Fu G. Fixation Pins Increase the Accuracy of Implant Surgery in Free-End Models: An In Vitro Study. J Oral Maxillofac Surg. 2023 May;81(5):593-601. doi: 10.1016/j.joms.2022.12.017. Epub 2023 Jan 28.
- Background: PubMed 31381178El Kholy K, Lazarin R, Janner SFM, Faerber K, Buser R, Buser D. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery. Clin Oral Implants Res. 2019 Nov;30(11):1067-1075. doi: 10.1111/clr.13520. Epub 2019 Aug 20.
- Background: PubMed 30589502El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 2019 Feb;21(1):101-107. doi: 10.1111/cid.12705. Epub 2018 Dec 27.
- Background: PubMed 34218450Kessler A, Le V, Folwaczny M. Influence of the tooth position, guided sleeve height, supporting length, manufacturing methods, and resin E-modulus on the in vitro accuracy of surgical implant guides in a free-end situation. Clin Oral Implants Res. 2021 Sep;32(9):1097-1104. doi: 10.1111/clr.13804. Epub 2021 Jul 17.
- Background: PubMed 33359299Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FR, Makvandi P. 3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications. Acta Biomater. 2021 Mar 1;122:26-49. doi: 10.1016/j.actbio.2020.12.044. Epub 2020 Dec 26.
- Background: PubMed 36625374Le V, Kessler A, Folwaczny M. Influence of DLP and SLA printer technology on the accuracy of surgical guides for implant dentistry in free-end situations. Int J Comput Dent. 2023 Sep 26;26(3):217-226. doi: 10.3290/j.ijcd.b3774115.
- Background: PubMed 28363503Matta RE, Bergauer B, Adler W, Wichmann M, Nickenig HJ. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J Craniomaxillofac Surg. 2017 Jun;45(6):804-808. doi: 10.1016/j.jcms.2017.02.015. Epub 2017 Feb 20.
- Background: PubMed 33504723Putra RH, Yoda N, Astuti ER, Sasaki K. The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis. J Prosthodont Res. 2022 Jan 11;66(1):29-39. doi: 10.2186/jpr.JPR_D_20_00184. Epub 2021 Jan 26.
- Derived from this study: PubMed 39578942Berta GM, Luigi C, Miguel PD, Carlos BJ. Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides. Clin Oral Implants Res. 2025 Mar;36(3):314-324. doi: 10.1111/clr.14384. Epub 2024 Nov 23.
- Individual participant dataSharing planned: No. Patients' personal data will not be published, however, the results of the scientific study will be published in a scientific dental journal.
Related trials for Dental Implant
Not yet recruiting
Free Soft Tissue Grafts (FSTG) Using Autograft Palatal Donor Tissue vs. Xenograft Collagen Matrix (Zderm™)
Gingival Recession Localized Moderate, Dental Implant
Not yet recruiting
Safety Assessment of Placing a Single Dental Implant Without Antibiotic Prophylaxis in Simple Cases: A Pilot Study
Tooth Loss and Rehabillitation, Dental Implant Failure
Active, not recruiting
L-PRF Block vs Composite Graft for Horizontal Ridge Augmentation
Alveolar Ridge Resorption After Extraction, Alveolar Bone Loss
RecruitingObservational study
Clinical and Radiographic Evaluation of Dentsply Sirona PrimeTaper Implants
Dental Implants
Active, not recruiting
The Aim of the Study Will be Clinically and Radio Graphically Comparison of Two Implant Designs Used to Treat Atrophied Mandible . Implant Design Comparison Will Done for Implant Stability,Peri-implant Soft Tissue Health Changes and Bone Changes .Patients Will be Divided Randomly Into Two Group
Dental Implant Bone Loss, Peri-Implant Health
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
MIGUEL PEÑARROCHA-DIAGO, Phd, DDS study director
University of Valencia
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Static computer-assisted guided surgery with analogic guide and Static computer-assisted guided surgery with CAD-CAM surgical guide in people with Dental Implant and Computer-assisted, run by University of Valencia at 1 site in Spain.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 10 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 5 Sep 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy in implants: vertical, apical and coronal horizontal deviations (time frame: 1 week post-operative). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06404385, which also lists 11 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Sep 2025.