AzTrials
AzTrials

ShockTREND-USNCT06418022

Evaluating Fluid Responsiveness in ICU Patients Using VTI and Trendelenburg Positioning

A study testing Trendelenburg positioning VTI in people with Shock and Fluid Overload, run by Northwell Health at 1 site in United States.

Withdrawn

Withdrawn. The study stopped before anyone enrolled.

Official record
Search all trials

Trial summary

Fluid administration is a commonly performed in the ICU for critically ill patients. However, it can lead to complications such as fluid overload, pulmonary edema, and increased mortality in some patients. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Shock, Fluid Overload, Cardiac Output, Low
What is being tested?
Trendelenburg positioning VTI
Could I receive a placebo?
No, everyone receives an active treatment
How many people
0 participants
Where
1 siteUnited States
Study dates
1 Apr 2024to 6 Mar 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult patients (≥ 18 years old) admitted to the medical or surgical ICU.
  • Patients who require fluid administration for suspicion of hypovolemia or indicated for volume expansion due to any one of the following: hypotension (systolic blood pressure < 90 mm Hg or mean arterial pressure < 65 mm Hg), tachycardia (heart rate > 100 beats per min), blood lactate > 2.0 mmol/L, skin mottling, oliguria (urine output < 30 ml/hr), or requiring vasopressor/inotrope support.
  • Patients who are able to tolerate the Trendelenburg position.

Who cannot join

  • Pregnancy.
  • Prisoners and institutionalized patients.
  • Patients who are not able to tolerate the Trendelenburg position. This includes patients with increased intra-cranial hypertension, intra-abdominal hypertension and gastric retention which places a risk for stomach fluid aspiration.
  • Unsatisfactory cardiac echogenicity (an inability to correctly align the Doppler beam to generate reliable VTI measurements at the left ventricular outflow tract [LVOT]).

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Lenox Hill Hospital- Northwell Health

    New York, New York, 10075

Other trials in United States

About this study

Official title: Evaluating Fluid Responsiveness in Intensive Care Unit Patients Using VTI and Trendelenburg Positioning. TREND-US Trial.

Fluid administration is a commonly performed in the ICU for critically ill patients. However, it can lead to complications such as fluid overload, pulmonary edema, and increased mortality in some patients. Therefore, identifying patients who are likely to respond to fluid therapy is crucial for optimizing their management. Several methods have been used to assess fluid responsiveness, such as passive leg raising, stroke volume variation, and cardiac output monitoring. However, these methods have limitations and may not be feasible in all patients. In this study, the investigators aim to evaluate the use of velocity time integral (VTI) and Trendelenburg positioning in predicting fluid responsiveness in ICU patients.

Read the detailed description

The investigators will perform an echocardiogram both in the supine and Trendelenburg positions for research purposes prior to the ICU team assessing fluid responsiveness (see paragraph below).

Critically ill patients in which fluid responsiveness is unclear typically admitted to the ICU routinely undergo a bedside echocardiogram in the supine position and then another echocardiogram still in the supine position after receiving IV fluids to assess the patient's fluid responsiveness (i.e., whether giving a small IV fluid bolus increases cardiac output). VTI is an echocardiographic surrogate for cardiac output and is routinely used in the ICU setting in addition to providing additional information on whether a patient is fluid responsive. This method is already standard practice in the medical and surgical ICU in our PCCM department.

Unfortunately, administering IV fluids can potentially cause adverse events such as pulmonary edema, heart failure, interstitial edema, respiratory failure, and death. The use of a method, such as the passive leg raise maneuver (i.e., raising patient's legs by 30 degrees for 1 minute and then evaluating hemodynamic measurements), help predict whether a patient would benefit from IV fluids prior to giving them fluids in order to prevent these aforementioned adverse events since it is a reversible process. Literature and current practice support the use of the passive leg raise (PLR) maneuver in predicting fluid responsiveness, where an increase of at least 15% signifies a positive fluid response. Similar to IV fluids, the PLR maneuver can cause adverse events, is cumbersome, and not feasible in certain circumstances. There is recent research which suggests that Trendelenburg positioning (TP) can be used as an alternative approach that is potentially safer and less cumbersome. This study aims to evaluate a cutoff increase in VTI that would be accurate in predicting fluid responsiveness in patients undergoing TP. As stated above, in our study we will see if placing the patient in TP (i.e., tilt head of the bed 15 degrees downward) will predict if the patient is fluid responsive. The investigators want use ROC analysis to determine the cutoff VTI increase and the accuracy of using TP in predicting fluid responsiveness. The gold standard is to check VTI prior to and after administering an IV fluid bolus and the current literature demonstrates that a VTI increase by 15% is indicative of an appropriate fluid response.

The patients in the study in the ICU will receive IV fluids regardless of our study based on the clinician's discretion (i.e., our study will not affect the decision of the clinician in any way). The bedside echocardiogram takes less than 2 minutes to perform and will not delay care.

Being tested
Trendelenburg positioning VTI
Keywords
fluid, responsiveness, VTI, ICU, POCUS, ultrasound, Trendelenburg
Medical subject headings
Shock, Edema, Cardiac Output, Low

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Trendelenburg positioning VTIDevice

    There are essentially two arms, whereby the patients is being compared to themselves. The "intervention arm" is the same patient undergoing TP from the baseline supine position to determine the change in VTI after subjecting to TP.

    We will be using a Sonosite PX ultrasound system, which is intended for diagnostic ultrasound imaging or fluid flow analysis of the human body and, more specifically, for our echocardiographic measurements of velocity time integral (VTI; surrogate for stroke volume and cardiac output). The Sonosite PX is a general-purpose ultrasound system intended for use by qualified physicians and healthcare professionals, for evaluation by ultrasound imaging or fluid flow analysis of the human body. This is an FDA-cleared (510K# K200964) commercial device legally marketed in the United States that is being used in accordance with labeling.

Study groups in NCT06418022
Study groupRoleWhat they receive
Fluid challenge (control)OtherThis study is evaluating the potential of Trendelenburg positioning (TP) in determining fluid responsiveness by using the change in velocity time integral (VTI), and echocardiographic parameter that can be used as a surrogate for stroke volume and cardiac output. There are essentially two arms, whereby the patients is being compared to themselves. The "control arm" is the patient receiving a fluid challenge (FC; IV fluid bolus of 500cc crystalloids- either 0.9% Normal Saline or Lactated Ringer's solution) that the clinician would have given regardless of the study; the change of VTI is collected after administration of IV fluids with comparison to the baseline supine position. The "intervention arm" is the same patient undergoing TP from the baseline supine position to determine the change in VTI after subjecting to TP.
Receives: Device: Trendelenburg positioning VTI

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in VTI cutoff in TP that predicts fluid responsiveness

    The objective of this study is to determine the change in VTI cutoff with Trendelenburg positioning that would predict fluid responsiveness in medical and surgical intensive care unit patients.

    Measured: ~1 year

Secondary outcomes (6)
  1. Determine if patient factors are independently associated with fluid responsiveness

    Evaluate other patient factors (e.g., demographics) to determine if they are independently associated with fluid responsiveness.

    Measured: ~1 year

  2. Association of Trendelenburg positioning on the effect on hemodynamic parameters

    Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of blood pressure (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).

    Measured: ~1 year

  3. Association of Trendelenburg positioning on the effect on hemodynamic parameters

    Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of heart rate (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).

    Measured: ~1 year

  4. Association of Trendelenburg positioning on the effect on hemodynamic parameters

    Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of pulse pressure (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).

    Measured: ~1 year

  5. Association of Trendelenburg positioning on the effect on hemodynamic parameters

    Evaluate the effect of Trendelenburg positioning (TP) and fluid challenge (FC) on hemodynamic parameter of central venous pressure (i.e., if there is a statistically significant change in the hemodynamic parameter after TP or FC).

    Measured: ~1 year

  6. Evaluate the predictive accuracy of the change in VTI versus other hemodynamic parameters

    Use receiver operating characteristic (ROC) curves to compare the predictive accuracy of the change in VTI compared to the change of certain hemodynamic parameters (e.g., pulse pressure, systolic blood pressure, diastolic blood pressure) with Trendelenburg positioning.

    Measured: ~1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 May 2024
  2. Study start1 Apr 2024
  3. Primary completion6 Mar 2025
  4. Study completion6 Mar 2025

Why it stopped: NO PATIENTS ENTERED

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Model description
This is a single-center, minimal risk study that will include a total of 400 critically ill patients, aged 18 and older, that require fluid administration. In prior studies, fluid responsiveness has been shown after an IV fluid bolus with ≥15% increase in VTI or after a passive leg raise (PLR) with ≥ 15% increase in VTI. Similar to the other maneuvers such as the PLR maneuver, we hope to find an optimal cutoff in the increase in VTI after Trendelenburg positioning based on ROC analysis, with an increase of VTI \>15% in patients after receiving IV fluids as the gold standard. There will be no intervention arm and patients will serve as their own control.
Masking
None (open label)
Enrolment
0 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06418022
Sponsor's protocol ID
23-0441
Acronym
TREND-US
Status last verified
Oct 2026
First submitted
6 May 2024
Last updated
2 Nov 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Trendelenburg positioning VTI in people with Shock and Fluid Overload, run by Northwell Health at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: withdrawn, as of the sponsor's last update on 2 Nov 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study was withdrawn before enrolling participants, so there are no results.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in VTI cutoff in TP that predicts fluid responsiveness (time frame: ~1 year). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in