AzTrials
AzTrials

Coronary Artery DiseaseNCT06441539

Bingo Drug-eluting Balloon Versus a Drug-eluting Stent for Coronary Bifurcation Lesions

A study testing Bingo® Paclitaxel coated balloon and Xience® Alpine Everolimus Eluting Coronary Stent System in people with Coronary Artery Disease, run by Yinyi(Liaoning) Biotech Co., Ltd..

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Bingo drug-eluting balloon versus a drug-eluting stent for coronary bifurcation lesions: a prospective, multi-center, randomized, non-inferiority trial Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Coronary Artery Disease
What is being tested?
Bingo® Paclitaxel coated balloon and Xience® Alpine Everolimus Eluting Coronary Stent System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
218 participants
Where
No sites listed yet
Study dates
1 Jul 2024to 31 May 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Clinical Inclusion Criteria:

  1. Age 18 to 80
  2. Patients with chronic stable coronary artery disease, or unstable angina, or NSTEMI (Grace score<140), or STEMI more than one week
  3. Subjects suitable for PCI
  4. Subjects understand the trial purpose, volunteer to participate and sign informed consent form

Angiographic Inclusion Criteria (by visual):

  1. One coronary de novo bifurcation lesion (including Medina classification: 1,1,1 / 1,0,1 / 0,1,1, which need to be treated for both main and side branches)
  2. The reference vessel diameter of main branch is between 2.5 to 4.0 mm, length ≤ 30 mm. Before lesion preparation, lesion diameter stenosis shall be ≥70%, or ≥50% with evidence of myocardial ischemia
  3. The reference vessel diameter of side branch is ≥2.0 mm, length <20 mm. Before lesion preparation, lesion diameter stenosis shall be ≥70%
  4. No more than 3 lesions on the non-target vessel in the same operation, and shall be successfully treated before the target vessel
  5. No more than 1 non-target lesion on the target vessel in the same operation, and shall be successfully prepared before the target lesion (successful preparation of non-target lesion is defined as residual stenosis ≤30% and TIMI flow 3). After randomization, the non-target lesion shall be treated according to the assigned group, for the experimental group, using the experimental DCB is recommended; for the control group, using DES is recommended; Independent lesion on the same coronary artery is defined as interval >5 mm
  6. The target lesions of main and side branches must be successfully prepared (successful preparation is defined as: residual stenosis ≤30% , without NHLBI type C or above dissection, and TIMI flow 3)

Clinical Exclusion Criteria:

  1. Severe heart failure (NYHA IV), cardiogenic shock or severe valvular heart disease
  2. Left ventricular ejection fraction ≤35%
  3. Severe renal insufficiency (eGFR <30 ml/min)
  4. Severe liver insufficiency (glutamate transaminase (ALT) or glutamate transaminase (AST) >3 times the upper limit of normal)
  5. Pregnant women or planned pregnancy
  6. With a known allergy to heparin, contrast agent, paclitaxel and everolimus
  7. Unable to receive antiplatelet agents and anticoagulants, bleeding tendency or coagulopathy
  8. Life expectancy does not exceed 1 year
  9. Participating in other drug or device clinical trials without reaching the primary endpoint
  10. Subjects who had undergone coronary revascularization in the last 6 months
  11. Subjects not eligible by the investigator for other reasons

Angiographic Exclusion Criteria (by visual):

  1. In-stent restenosis lesion
  2. Left main bifurcation lesion
  3. Chronic total occlusive lesion
  4. Target vessel is severely distorted, angulated or calcified, which is anticipated difficult to cross for balloon or stent
  5. Target lesion remains significant residual thrombus after preparation

About this study

Official title: Bingo Drug-eluting Balloon Versus a Drug-eluting Stent for Coronary Bifurcation Lesions: a Prospective, Multi-center, Randomized, Non-inferiority Trial

Bingo drug-eluting balloon versus a drug-eluting stent for coronary bifurcation lesions: a prospective, multi-center, randomized, non-inferiority trial

Being tested
Bingo® Paclitaxel coated balloon, Xience® Alpine Everolimus Eluting Coronary Stent System
Keywords
Coronary bifurcation, Percutaneous coronary intervention, Drug-coated balloon
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Bingo® Paclitaxel coated balloonDevice

    Treat the main vessel and side branch of bifurcation lesion with drug-eluting balloon

  • Xience® Alpine Everolimus Eluting Coronary Stent SystemDevice

    Treat the main vessel of bifurcation lesion with drug-eluting stent, and treat the side branch with uncoated balloon or drug-eluting stent

Study groups in NCT06441539
Study groupRoleWhat they receive
drug-eluting balloonExperimentalTreat the main vessel and side branch of bifurcation lesion with drug-eluting balloon
Receives: Device: Bingo® Paclitaxel coated balloon
drug-eluting stentActive comparatorTreat the main vessel of bifurcation lesion with drug-eluting stent, and treat the side branch with uncoated balloon or drug-eluting stent
Receives: Device: Xience® Alpine Everolimus Eluting Coronary Stent System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. in-segment late lumen loss in main branch

    use quantitative coronary angiography by an independent core laboratory

    Measured: 9 months

Secondary outcomes (13)
  1. Procedure success rates

    include device success, lesion success and clinical success

    Measured: up to 7 days in-hospital

  2. Minimal lumen diameter

    use quantitative coronary angiography by an independent core laboratory

    Measured: 9 months

  3. Diameter stenosis

    use quantitative coronary angiography by an independent core laboratory

    Measured: 9 months

  4. Dissection and type

    use quantitative coronary angiography by an independent core laboratory

    Measured: 9 months

  5. in-segment late lumen loss in side branch

    use quantitative coronary angiography by an independent core laboratory

    Measured: 9 months

  6. Binary restenosis

    use quantitative coronary angiography by an independent core laboratory

    Measured: 9 months

  7. Target lesion failure

    include cardiac death, target vessel myocardial infarction, clinically driven target lesion revascularization

    Measured: 1, 6, 9 and 12 months

  8. Target lesion thrombosis

    include acute, sub-acute, late and very late period

    Measured: 1, 6, 9 and 12 months

  9. BARC bleeds

    type 2, 3 or 5

    Measured: 1, 6, 9 and 12 months

  10. Stroke

    any stroke

    Measured: 1, 6, 9 and 12 months

  11. Myocardial infarction

    include peri-operation and 12 months

    Measured: Peri-operation and 12 months

  12. Death

    include cardiac and all-cause death

    Measured: 1, 6, 9 and 12 months

  13. Major Adverse Cardiovascular Events

    composite endpoint with death, myocardial infarction and target vessel revascularization

    Measured: 1, 6, 9 and 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Jun 2024
  2. Study start1 Jul 2024 (estimated)
  3. Primary completion28 Feb 2025 (estimated)
  4. Study completion31 May 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
218 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06441539
Sponsor's protocol ID
LNYY2024001
Status last verified
May 2024
First submitted
22 May 2024
Last updated
4 Jun 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Bingo® Paclitaxel coated balloon and Xience® Alpine Everolimus Eluting Coronary Stent System in people with Coronary Artery Disease, run by Yinyi(Liaoning) Biotech Co., Ltd..

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 4 Jun 2024. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

in-segment late lumen loss in main branch (time frame: 9 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Jun 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in