Ventilator LungNCT06483529

Respiratory Mechanics Measurement of Ventilated Patients Through Low-frequency Oscillometry Technique

A study testing compliance measurement in people with Ventilator Lung, run by Universitair Ziekenhuis Brussel at 1 site in Belgium.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Respiratory failure has historically been one of the most important causes for admittance of patients to the critical care unit. This problem was the most important reason during the COVID-19 pandemic. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Ventilator Lung
What is being tested?
compliance measurement
Could I receive a placebo?
No, everyone receives an active treatment
How many people
21 participants
Where
1 siteBelgium
Study dates
18 Sep 2023to 31 Dec 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • intubation
  • Controlled ventilation with an intention to continue controlled ventilation for the following 4 hours.
  • Richmond agitation sedation scale of -4 or less
  • Hemodynamically stable patient with either
  • unchanged vasopressor dose administration for at least 60 minutes before the start of the measurements
  • no vasopressor need and no vasopressor initiated within 60 minutes of measurements
Show all 10Show fewer
  • No planned intervention in the coming 2 hours
  • Survival for at least 48 hours
  • Protective ventilation (inspired oxygen concentration≤60%, plateau pressure ≤30 cmH2O , driving pressure≤ 15cmH2O)
  • PEEP (Positive End Expiratory Pressure) ≤10

Who cannot join

  • assist ventilation
  • Ventilator asynchronies
  • Intermittent spontaneous breathing
  • nitric oxide therapy
  • presence of an extra corporeal membrane oxygenation device
  • Ventilation is not possible within the lower and upper inflection point of the low flow pressure volume curve.
Show all 12Show fewer
  • Unstable right heart failure
  • Unstable lung embolism
  • Standard of care without Sedline® or invasive arterial catheter
  • Do not reanimate code of 2, 3 or 4
  • Subjects who are healthy, minors, pregnant women, patients in emergency situation
  • Outside the age range 18 to 84 years

Trial locations and contacts

1 site in 1 country.

joop Jonckheer, MD, PhD contact

028012679 ext. +32

joop.jonckheer@uzbrussel.be

Belgium1 site, 1 recruiting
  • Universitair Ziekenhuis Brussel

    Jette, Brussel Hoofstedelijk Gewest, 1090

    Joop Jonckheer, MD, PhD, 028012679 ext. +32, joop.jonckheer@uzbrussel.be

    Recruiting

Other trials in Belgium

About this study

Official title: Respiratory Mechanics Measurement of Ventilated Patients Through Low-frequency Oscillometry Technique, an Explorative Study

Respiratory failure has historically been one of the most important causes for admittance of patients to the critical care unit. This problem was the most important reason during the COVID-19 pandemic. Following the evolution of the physiology of the lung has therefore been the number one concern during these challenging times in the intensive care unit (ICU). Respiratory oscillometry (RO) identifies the lung impedance by applying small pressure oscillations onto the breathing or ventilation. Information about the respiratory mechanics can be extracted out of this impedance, including the resistance (R) and compliance (C) of the lung. The VUB developed a robust, patient safe RO measurement protocol that delivers high quality measurements with the least possible interference with the patient's breathing/ventilation. The technique challenges current state-of-the-art techniques also aiming at identifying R and C of the respiratory system (not exclusively RO). The RO measurement protocol is in line with the technical standards of the ERS (European Respiratory Society) and has been successfully and safely tested on emulators and some parts on test subjects. The clinical investigation aims at a powered equivalence investigation between the RO measurement protocol and a standard of care dynamic compliance estimate on invasive ventilated patients. As secondary objectives, the feasibility of the RO techniques will be investigated during pressure support ventilation and the RO estimates will also be compared with other accepted respiratory mechanics estimation tools. To enable the investigation, a RO algorithm is developed, and a RO measurement extension is implemented in the DemcAir® ventilation system of Demcon. This was a fully tested ventilator that received a CE mark under the previous MDD regulation. However, Demcon, which produces ventilator parts for other commercial partners, removed the label to avoid competition with their partners. The ventilator will only execute the protocol on demand and save the data on an USB stick available in the ventilator. At any time, the RO measurement procedure can be stopped, and the ventilator will return to its initial ventilation. The USB stick is used to transport the data to a separate (VUB) laptop where the data processing is done.

Conditions
Ventilator Lung
Being tested
compliance measurement
Keywords
oscillometry, intensive care unit, intubated patients, compliance, resistance, impedance
Medical subject headings
Patient Compliance

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • compliance measurementDiagnostic test

    compliance can be measured by analyzing pressure volume curves generated through different methods

Study groups in NCT06483529
Study groupRoleWhat they receive
ROELEC PROTOCOLExperimentalROELEC measurements consist of the application of a sine or multisine excitation pressure signal superimposed on the ventilation signal. The novelties are in the smart design of the excitation signal, not the way it is applied to the patient.
Receives: Diagnostic Test: compliance measurement
dynamic P/V curvesActive comparatordynamic ventilatory pressure volume curves generated during the standard ventilation settings
Receives: Diagnostic Test: compliance measurement
low flow P/V curvesOtherstatic ventilatory pressure volume curves will be generated during the procedure to assure that the patients ventilation is between the lower inflection point and the higher inflection point. this P/V curves will also be analysed but will not be included in the primary endpoint analysis
Receives: Diagnostic Test: compliance measurement
SOTAOtherStandard of care oscillometry protocol will also generate low flow P/V curves but will not be included in the primary endpoint analysis
Receives: Diagnostic Test: compliance measurement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. compliance

    compliance of the lung expressed in "ml/cmH20 "

    Measured: Twice a day with at least 4hour interval, during 1 hour, compliance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve

Secondary outcomes (2)
  1. resistance

    resistance of the lung expressed in cmH20/L/sec

    Measured: Twice a day with at least 4hour interval, during 1 hour, resistance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve

  2. impedance

    lung impedance expressed in Ohm

    Measured: Twice a day with at least 4hour interval, during 1 hour, impedance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Jul 2024
  2. Study start18 Sep 2023
  3. Primary completion30 Sep 2024 (estimated)
  4. Study completion31 Dec 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Single group
Model description
prospective equivalence study with a two-arm crossover design - explorative pilot study
Masking
Quadruple blind
Who is masked
Participant, Care provider, Investigator, Outcomes assessor
Enrolment
21 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06483529
Sponsor's protocol ID
EC-2023-188-MDR
Status last verified
Jun 2024
First submitted
27 Sep 2023
Last updated
3 Jul 2024
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: The Clinical Trial Summary Excel file and the .mat files can be shared safely on a request basis, given the anonymization scheme. This will allow other researchers to run their processing on the dataset and reach their own conclusions. The GDPR additional Excel file, or Mapping Table, and the eCRF will never be shared with anyone outside the principal investigator/authorized study member. With it, anyone can identify the patients who took part in the clinical trial.

Questions about this trial

What is this clinical trial studying?

A study testing compliance measurement in people with Ventilator Lung, run by Universitair Ziekenhuis Brussel at 1 site in Belgium.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 10 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 3 Jul 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact joop Jonckheer, MD, PhD (028012679 ext. +32, joop.jonckheer@uzbrussel.be), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

compliance (time frame: Twice a day with at least 4hour interval, during 1 hour, compliance will be measured in every interventional action: ROELEC protocol, SOTA, dynamic P/V curve and low flow P/V curve). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Jul 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in