Bone LossCustomPNNCT06527664
Innovative Technologies for Salvage Procedures of Failed Treatments of Osteoarthritis: Biomimetics Solutions (CustomPN)
An observational study of Bone Loss and Hip Prosthesis Infection, run by Istituto Ortopedico Rizzoli at 1 site in Italy.
Trial summary
In this prospective multicenter study, a population of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant for non-oncological reasons, will be included. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Bone Loss, Hip Prosthesis Infection, Arthroplasty Complications
- What is being tested?
- custom-made acetabular implant
- Type of treatment
- Medical device
- How many people
- 15 participants
- Where
- 1 siteItaly
- Study dates
- 1 Oct 2024to 30 Sep 2026
- Phase
- Observational
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: The study population will consist of adult individuals (minimum age: 18 years) consecutively treated for revision hips (non-oncological reasons) requiring a custom-made acetabular implant. Patients will be enrolled in 4 tertiary centers (multicenter prospective study). Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls).
Who may be able to join
- need of custom-made acetabular implant on the basis of CT and X-ray evaluation ()
- pre-operative CT scan
- adults patients (minimum age: 18 years)
- complete medical charts
- patients' availability
Who cannot join
- oncological reasons for revision
- other types of revision implant (non custom)
- inadequate medical chart
- lack of pre-operative CT scan
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Francesco Traina, Prof contact
Italy1 site, 1 recruiting
- Recruiting
Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
Bologna, 40136
Francesco Castagnini, MD, +390516366418, francescocastagnini@hotmail.it
About this study
Official title: Innovative Technologies for Cost-Effective Healthcare Delivery for Salvage Procedures of Failed Treatments of Osteoarthritis: Specific Biomimetics Solutions to Reduce a Growing Problem With a High Social and Economic Impact.(CustomPN)
In this prospective multicenter study, a population of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant for non-oncological reasons, will be included. The custom-made implant is a personalized implant produced using additive manufacturing, based on the pre-operative CT scan that details the bone damage. Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls).
Preoperatively, the patient will undergo a clinical evaluation. Data will be collected on the patient's general health status with the Charlson score, the reason for revision, number of revisions, type of implant in place, and the time elapsed between the failed implant and the revision in question. The bone deficit will be studied through CT measurements according to qualitative and quantitative scales. During the surgery, information on intraoperative complications will be collected. In the postoperative period, perioperative complications will be collected according to the Clavien Dindo classification. The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1, 3, 12, 24, and 36 months after revision. They include the Harris Hip Score clinical score, the EQ-5D PROM, and the patient's satisfaction level (qualitative assessment in 4 grades: unsatisfied, slightly satisfied, moderately satisfied, fully satisfied). The positional parameters of the implant will be evaluated, as compared to the immediate post-operative X-ray: acetabular abduction, acetabular anteversion, center of rotation height, center of rotation medialization, and inclination of the custom-made component. From 12 months onwards, the osteointegration characteristics of the component will be assessed: presence of radial trabeculae at the interface, superolateral and inferior reinforcements, stress shielding, absence of radiolucent lines. Re-revision rates will be determined using the Kaplan-Meier method. The reasons for re-revision will be noted.
Read the detailed description
Osteoarthritis (OA) increased from 247.51 million people in 1990 to 527,81 million in 2019. OA places a huge burden on healthcare services accounting for 1-2,5% of the gross national products and the cost is expected to quadruple by 2030. Total joint replacement (TJR) represents the standard of care of end-stage OA. TJR is projected to nearly double by 2026. Unfortunately, TJR are subject to failure, thus the number of revision procedures is also growing, accounting for 5-6% of all TJR. Failure of TJR represents a dramatic event for patients and National Health Systems. Patients suffer enormous disability, with impact on function, emotional sphere, and loss of autonomy. The average cost of treatment is almost doubled compared to TJR, and in case of periprosthetic joint infections almost tripled. In patients under 65 years (with a failure rate of 9%-12%), the full return to work is reported only in 7%-33% of the cases, and not earlier then 1 year after the surgery, while around 50% retired or remained on welfare benefits. Current technology is not enough to overcome this set of problems, while actual projections predict a 43%-70% increase in revisions by 2030. In particular, revision hips involve various diagnoses and settings: in some cases, the severe bone loss makes the reconstruction very complex. In these cases, acetabular reconstruction can be performed with off-the-shelf implants, but outcomes are not always consistent and reproducible. Thus, in cases of severe acetabular bone loss, it may be very useful to proceed with a customized implant, designed according to the patient's needs. Implants produced in this way are designed based on the patient's pre-operative CT scan using additive manufacturing technology. The purpose is to offer a personalized bone filling of the defect with a highly porous interface that promotes osteointegration. Currently, most of the custom-made implants are performed for oncological cases. On the contrary, there are few indications on the clinical and radiological outcomes of custom-made acetabular reconstructions in revision hips with severe bone loss in non-oncological cases. The purpose of this project is to validate an innovative and reliable technology (custom-made acetabular component produced using additive manufacturing) for managing non-oncological revisions, assessing short term outcomes.
The aims are:
Description of demographic characteristics and bone defect in candidates for acetabular reconstruction with custom-made implants Perioperative complications and implant survival Clinical evaluation of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss (clinical score Harris Hip Score; subjective score PROM EQ-5D; post-operative patient satisfaction level) Radiographic evaluation (positioning and osteointegration) of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss This is a prospective multicenter study. The study population will consist of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant. Patients with a diagnosis leading to an oncological revision will not be included. The custom-made implant is a personalized implant created by an external company based on the pre-operative CT scan that details the bone damage. Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls). In these cases, off-the-shelf therapeutic options are limited and achieve uncertain outcomes: therefore, a custom-made component with ultra-porous anchoring surfaces can represent a highly advantageous therapeutic choice. After identifying the suitable patient and obtaining their consent for the study, a pre-operative CT scan will be performed as per normal clinical practice for every revision. After uploading it to the dedicated website or app of the company, this CT scan will be used for the manufacturing of the custom-made implant by a third-party company. The company will also provide plastic phantoms for preliminary study of the implant. Upon approval of the implant production, the company will manufacture the implant according to current regulations and production techniques, following previous and established clinical practice. The device will be accompanied by personalized instrumentation, such as cutting guides, positioners, calipers, and plastic simulation phantoms, to facilitate the surgical procedure. The implant and the produced instrumentation will be delivered to the reference center after performing the patient's surgical planning.
Preoperatively, the patient will undergo an evaluation with the Harris Hip score clinical score. Additionally, data will be collected on the patient's general health status with the Charlson score, the reason for revision, number of revisions, type of implant in place, and the time elapsed between the failed implant and the revision in question. The bone deficit will be studied through CT measurements according to qualitative and quantitative scales.
During the surgery, information on intraoperative complications will be collected. In the postoperative period, perioperative complications will be collected according to the Clavien Dindo classification. The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1, 3, 12, 24, and 36 months after revision. They include the Harris Hip Score clinical score, the EQ-5D PROM, and the patient's satisfaction level (qualitative assessment in 4 grades: unsatisfied, slightly satisfied, moderately satisfied, fully satisfied). The positional parameters of the implant will be evaluated, as compared to the immediate post-operative X-ray: acetabular abduction, acetabular anteversion, center of rotation height, center of rotation medialization, and inclination of the custom-made component. From 12 months onwards, the osteointegration characteristics of the component will be assessed: presence of radial trabeculae at the interface, superolateral and inferior reinforcements, stress shielding, absence of radiolucent lines. Re-revision rates will be determined using the Kaplan-Meier method. The reasons for re-revision will be noted.
- Being tested
- custom-made acetabular implant
- Keywords
- revision hip arthroplasty, custom-made implant, additive manufacturing
- Medical subject headings
- Bone Diseases, Metabolic
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
custom-made acetabular implantDevice
custom-made acetabular implant produced with additive manufacturing, to fill the bony loss in Paprosky III bone defects
| Study group | Role | What they receive |
|---|---|---|
| Custom-made | Revision hip arthroplasty performed for non-oncological reasons, with Paprosky III bone loss Receives: Device: custom-made acetabular implant |
What is being measured
The primary outcome is the main question the study is designed to answer.
Perioperative complications
Clavien-Dindo classification: 5 stages with IIIA and IIIB, IV A and IV B. I stage: minimal complications, V stage: death of the patient.
Measured: 0-30 days
Objective clinical outcomes
Harris Hip Score. Numerical scale assessing mobility, pain and functionality. Range: 0-100. 100 is the best objective outcome.
Measured: 0-18 months
Subjective clinical outcomes
EQ-5D-5L. Subjective score with 5 dimensions: mobility, self-care, pain, usual activity, anxiety/depression (5 levels per each assessment). Weighted index on a 0-1 scale. Best outcome: 1
Measured: 0-18 months
Subjective clinical outcomes (satisfaction)
Percentage of satisfied patients per single level. 4 levels, from not satisfied to completely satisfied.
Measured: 0-18 months
Survival rates
Survival rates using Kaplan Meier curve. Range: 0-100%. Best outcome: 100%
Measured: 0-18 months
Secondary outcomes (1)
Osseointegration of the acetabular component
Percentages of cases with good osseointegration of the acetabular component according to Moore's criteria. At least three criteria among: presence of radial trabeculae at the interface, presence of superolateral buttress, presence of inferior buttress, presence of medial stress shielding, absence of radiolucent lines. Range: 0-100%. Best outcome: 100%
Measured: 12-18 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 Jul 2024
- Study start1 Oct 2024
- Primary completion30 Mar 2026 (estimated)
- Study completion30 Sep 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Bone LossStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 15 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Istituto Ortopedico Rizzoli
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Francesco Traina, Prof, Principal investigator, IRCCS Istituto Ortopedico Rizzoli
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06527664
- Sponsor's protocol ID
- 344/2024/Oss/IOR
- Acronym
- CustomPN
- Status last verified
- Feb 2026
- First submitted
- 23 Jul 2024
- Last updated
- 23 Feb 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Romagnoli M, Zaffagnini M, Carillo E, Raggi F, Casali M, Leardini A, Marcheggiani Muccioli GM, Grassi A, Zaffagnini S. Custom-made implants for massive acetabular bone loss: accuracy with CT assessment. J Orthop Surg Res. 2023 Sep 30;18(1):742. doi: 10.1186/s13018-023-04230-5.
PubMed 37777776Pandey AK, Zuke WA, Surace P, Kamath AF. Management of acetabular bone loss in revision total hip replacement: a narrative literature review. Ann Jt. 2023 Oct 5;9:21. doi: 10.21037/aoj-23-23. eCollection 2024.
PubMed 38694811Jones SA, Parker J, Horner M. Can a reconstruction algorithm in major acetabular bone loss be successful in revision hip arthroplasty? Bone Joint J. 2024 May 1;106-B(5 Supple B):47-53. doi: 10.1302/0301-620X.106B5.BJJ-2023-0809.R1.
PubMed 38688489Kim K, Sandiford NA. The Role of Three-Dimensional Custom Printing in Revision Total Hip Arthroplasty. Surg Technol Int. 2023 Sep 15;42:369-373. doi: 10.52198/23.STI.42.OS1698.
PubMed 37675989Pardo F, Bordini B, Castagnini F, Giardina F, Faldini C, Traina F. Are powder-technology-built stems safe? A midterm follow-up registry study. J Mater Sci Mater Med. 2021 Jan 20;32(1):10. doi: 10.1007/s10856-020-06481-8.
PubMed 33471238Castagnini F, Mariotti F, Tassinari E, Bordini B, Zuccheri F, Traina F. lsolated acetabular revisions of articular surface replacement (ASR) XL implants with highly porous titanium cups and Delta bearings. Hip Int. 2021 Mar;31(2):250-257. doi: 10.1177/1120700019874442. Epub 2019 Sep 4.
PubMed 31480877