AzTrials
AzTrials

Denture,CompleteNCT06588140

Conventional Versus 3D Printing Duplication Techniques of Complete Denture

A study testing Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate., Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin. and Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin. in people with Denture,Complete and Edentulous Alveolar Ridge, run by Ain Shams University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Twenty completely edentulous patients with old, removable dentures with ill-fitting maxillary dentures, proper vertical dimension, and proper occlusion will be recruited for this trial. Read more about this study

Who is it for?
Ages 50 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Denture,Complete, Edentulous Alveolar Ridge
What is being tested?
Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate., Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin. and Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin.
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteEgypt
Study dates
1 Sep 2024to 1 Nov 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Patients with old complete dentures without lost vertical dimension.
  • Patients with correct centric occluding relation.
  • The dentures should be esthetically and functionally satisfactory and exhibit reasonable retention and stability

Who cannot join

  • The presence of ridge or soft tissue pathology.
  • Diminished saliva production.
  • A history of medications affecting saliva quantity or quality.
  • Patients with temporomandibular joint problems.
  • The presence of sever ridge undercut.
  • Debilitated patients

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Ain Shams University

    Cairo, 12345

Other trials in Egypt

About this study

Official title: Comparison of Retention Between Different Duplication Techniques of Complete Dentures: Conventional Versus CAD/CAM: A Within Subject Controlled Clinical Trial

Twenty completely edentulous patients with old, removable dentures with ill-fitting maxillary dentures, proper vertical dimension, and proper occlusion will be recruited for this trial. They will be rehabilitated with duplicated complete dentures manufactured by conventional and two different 3D-printed CAD-CAM Complete Removable Dentures techniques.

Outcomes will be evaluated, including denture retention, which will be evaluated using a digital force gauge, and occlusal force distribution by using a t-scan.

Read the detailed description

The study will be conducted at the outpatient clinic of the Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University. This within-subject controlled clinical trial will involve twenty completely edentulous patients with old, ill-fitting maxillary complete dentures, who will be selected and recruited following approval by the Research Ethics Committee of the Faculty of Dentistry, Ain Shams University (FDASU-REC). These patients will be rehabilitated with duplicated complete dentures produced through conventional methods and two distinct 3D-printed CAD/CAM techniques.

Group I: The duplication of a refitted complete removable denture will be performed using the conventional heat-cured technique.

Group II: The refitted complete denture will be duplicated using a 3D-printed CAD/CAM technique, where the denture base will be printed separately with pink resin, and the teeth will be printed as a single unit in tooth-colored resin, followed by assembly of the two components.

Group III: The refitted complete denture will be duplicated using a 3D-printed CAD/CAM technique, with the entire denture printed as a single unit in tooth-colored resin, and the denture flange veneered with pink resin.

Outcomes will be evaluated by measuring denture retention with a digital force gauge and occlusal force distribution using the T-Scan system. The collected data will be recorded, tabulated, and subjected to statistical analysis using appropriate tests for group comparisons.

Being tested
Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate., Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin., Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin.
Keywords
CAD-CAM, Complete Dentures, Copying , Denture

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate.Device

    The duplication of a refitted complete removable denture will be performed using conventional heat-cured polymethyl methacrylate through the conventional heat-cured polymerization technique.

  • Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin.Device

    The duplication of a refitted complete removable denture will be performed using a 3D-printed CAD/CAM technique, where the denture base is printed separately with pink polymethyl methacrylate resin, and the teeth are printed as a single unit using tooth-colored resin, followed by the assembly of the two components.

  • Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin.Device

    The duplication of a refitted complete removable denture will be performed using a 3D-printed CAD/CAM technique, where the denture base is printed as a single unit using tooth-colored resin, and the denture flange will be veneered with pink polymethyl methacrylate resin.

Study groups in NCT06588140
Study groupRoleWhat they receive
conventional heat-cured duplication technique.Active comparatorDuplication of refitted complete removable dentures by conventional heat-cured technique from heat-cured polymethyl methacrylate resin.
Receives: Device: Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate.
3d Printed CAD/CAM duplication technique from Pink polymethyl methacrylate base resinExperimentalDuplication of a refitted complete removable denture will be produced using a 3D-printed CAD/CAM technique where the denture base will be printed separately using pink base polymethyl methacrylate resin, and the teeth will be printed as one unit using tooth-colored resin, followed by assembling the two components.
Receives: Device: Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin.
3d Printed CAD/CAM duplication technique from white polymethyl methacrylate base resinExperimentalDuplication of a refitted complete removable denture will be produced using a 3D-printed CAD/CAM technique where the denture will be printed as a single unit using tooth-colored resin, and the denture flange will be veneered with pink resin.
Receives: Device: Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Assessment of Retention of maxillary complete denture

    The retention of a maxillary complete denture will be assessed using a digital force gauge meter, with retention measurements recorded in Newtons.

    Measured: at the time of denture insertion

Secondary outcomes (1)
  1. Evaluation of occlusal force distribution between right and left side

    Occlusal force distribution will be assessed using the T-Scan III, with the results expressed as a percentage.

    Measured: at the time of denture insertion

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Sep 2024
  2. Study start1 Sep 2024
  3. Primary completion1 Oct 2024
  4. Study completion1 Nov 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Participant
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06588140
Sponsor's protocol ID
FDASU-Rec IR032421
Status last verified
Mar 2025
First submitted
5 Sep 2024
Last updated
6 Mar 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Duplicated refitted complete denture made from conventionally heat-cured polymethyl methacrylate., Duplicated refitted complete denture made from 3D-printed CAD/CAM pink polymethylmethacrylate acrylic resin. and Duplicated refitted complete denture made from 3D-printed CAD/CAM white polymethylmethacrylate acrylic resin. in people with Denture,Complete and Edentulous Alveolar Ridge, run by Ain Shams University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Mar 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Assessment of Retention of maxillary complete denture (time frame: at the time of denture insertion). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Mar 2025; AzTrials last refreshed its copy on 1 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in