AzTrials
AzTrials

Dental ImplantPhase 1NCT06599294

Accuracy of Intraoral Photogrammetry Scanner in Complete Arch Digital Implant Impression

A Phase 1 study testing Digital scanning and Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner. in people with Dental Implant, run by Ain Shams University at 2 sites in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Intra oral scanning can perform a full digital workflow right on the patient's mouth. Recently an intra-oral photogrammetry scanner has been introduced in the market that can make intra-oral tissue scanning in addition to a built-in photogrammetry technology so that it can capture fixture locations through special… Read more about this study

Who is it for?
Ages 20 to 50 years
Conditions the study is for
Dental Implant
What is being tested?
Digital scanning and Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
2 sitesEgypt
Study dates
20 Jun 2024to 20 Aug 2024
Phase
Phase 1
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 50 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • participants had received 4-6 implants in 1 edentulous arch.
  • Participants had received 1-piece implant-supported complete-arch fixed dental prostheses.

Who cannot join

  • Systemic conditions as diabetes.
  • Osteoporosis patients.
  • Immunocompromised patients.

Trial locations and contacts

2 sites in 1 country.

Egypt2 sites
  • Faculty of Dentistry Ain Shams University

    Cairo, Abbassia, 11566

  • Faculty of Dentistry Ain Shams University

    Cairo, Abbassia, 15666

Other trials in Egypt

About this study

Official title: Accuracy of Intraoral Photogrammetry Scanner (IPS) in Complete Arch Digital Implant Impression: an in Vivo Prospective Comparative Study

Intra oral scanning can perform a full digital workflow right on the patient's mouth. Recently an intra-oral photogrammetry scanner has been introduced in the market that can make intra-oral tissue scanning in addition to a built-in photogrammetry technology so that it can capture fixture locations through special intra-oral scan flags.

Read the detailed description

Intraoral scanning had several advantages to intraoral direct scanning, including less storage and transportation needs, faster scanning times, and increased patient comfort. The intraoral scan bodies are used as digital fixture locators when using IOSs for implant impressions.

Photogrammetry is the science and technology of obtaining reliable information about physical objects through the process of recording, measuring, and interpreting photographic images and patterns of electromagnetic radiant imagery. The utilization of photogrammetry in the dental field leads to exclusion of intraoral dental and gingival anatomies while scanning the implant coordinates. In addition, no need for stitching during full arch implant scanning which is reflected in the trueness and precision of the scanned object. Exclusion of unstable mucosa during scanning and avoidance of stitching make the passive seating of implant prosthesis a more predictable procedure especially when compared with intra-oral scanning only.

Up to this moment, all photogrammetry systems available in the market are considered extraoral systems that require an additional impression for soft tissue capture whether conventional or digital. Recently an intra-oral photogrammetry scanner (IPS) has been introduced in the market that can make intra-oral tissue scanning in addition to a built-in photogrammetry technology so that it can capture fixture locations through special intra-oral scan flags.

Conditions
Dental Implant
Being tested
Digital scanning, Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.
Keywords
Digital, photogrammetry, Intra oral scanner

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Digital scanningProcedure or surgery

    . For each patient three digital files will be obtained: One reference scan, one conventional IOS scan, and one IPS scan. All the STL files will be imported to dental CAD software, and scan bodies will be converted to implant multi-unit ti-base using a digital library. The updated STL files will be imported to inspection software Mimics for trueness assessments. The three-dimensional discrepancy between 2 STL files will be evaluated in terms of linear and angular deviation. A central point \& central axis of the virtual MUA ti-base was used for deviation measurements. Linear deviations will be assessed for each MUA tibase on the three-space axis (X longitudinal, Y lateral, and Z vertical) using the center of the ti-base heads for the deviation measurement. Angular deviations were assessed as the angles formed by the two lines passing perpendicularly through the centers of the test image and the reference image of each ti-base.

  • Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.Procedure or surgery

    . For each patient three digital files will be obtained: One reference scan, one conventional IOS scan, and one IPS scan. All the STL files will be imported to dental CAD software, and scan bodies will be converted to implant multi-unit ti-base using a digital library. The updated STL files will be imported to inspection software Mimics for trueness assessments. The three-dimensional discrepancy between 2 STL files will be evaluated in terms of linear and angular deviation. A central point \& central axis of the virtual MUA ti-base was used for deviation measurements. Linear deviations will be assessed for each MUA tibase on the three-space axis (X longitudinal, Y lateral, and Z vertical) using the center of the ti-base heads for the deviation measurement. Angular deviations were assessed as the angles formed by the two lines passing perpendicularly through the centers of the test image and the reference image of each ti-base.

Study groups in NCT06599294
Study groupRoleWhat they receive
intraoral photogrammetry scanningExperimentalNot described
Receives: Procedure: Digital scanning; Procedure: Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.
Intra oral scanningActive comparatorNot described
Receives: Procedure: Digital scanning; Procedure: Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Degree of Trueness

    The clinical performance of conventional intraoral scanners (IOS) and intraoral photogrammetry scanners (IPS) for each patient enrolled in the study with a paired comparison of the deviation differences

    Measured: 4 months following implant insertion

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Sep 2024
  2. Study start20 Jun 2024
  3. Primary completion10 Aug 2024
  4. Study completion20 Aug 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 1
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06599294
Sponsor's protocol ID
112899
Status last verified
Jul 2024
First submitted
7 Sep 2024
Last updated
19 Sep 2024
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A Phase 1 study testing Digital scanning and Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner. in people with Dental Implant, run by Ain Shams University at 2 sites in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Sep 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 1 studies test a treatment in a small group of people for the first time or in a new way, mainly to check safety and find the right dose.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Degree of Trueness (time frame: 4 months following implant insertion). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Sep 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in