AzTrials
AzTrials

Labor AnalgesiaNCT06602440

Effect of Epidural Catheter Retention Depth on Labor Analgesia Performed in DPE Combined With PIEB Model

A study testing The indwelling length of epidural catheter is 3 centimeters., The indwelling length of epidural catheter is 5 centimeters. and The indwelling length of epidural catheter is 7 centimeters. in people with Labor Analgesia, run by General Hospital of Ningxia Medical University at 1 site in China.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to observe the appropriate indwelling depth of epidural catheter when labor analgesia is performed in the mode of DPE combined with PIEB, and then shorten the onset time of labor analgesia and reduce the occurrence of catheter-related adverse outcomes. Read more about this study

Who is it for?
Ages 18 to 45 years, women onlyHealthy volunteers can take part
Conditions the study is for
Labor Analgesia
What is being tested?
The indwelling length of epidural catheter is 3 centimeters., The indwelling length of epidural catheter is 5 centimeters. and The indwelling length of epidural catheter is 7 centimeters.
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
102 participants
Where
1 siteChina
Study dates
1 Jul 2024to 1 Oct 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 45 years
  • Women only
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Those aged 18 to 45 years old;
  • Pregnancy lasts for 37 to 42 weeks;
  • Single healthy pregnant women with cervical dilation < 3.0 cm who wish to use epidural labor analgesia;
  • The NRS score of uterine contraction pain is > 3;
  • ASA grade I-II;
  • BMI ≤ 40 kg/m².

Who cannot join

  • Those with contraindications to intraspinal anesthesia;
  • Those with a history of allergy to local anesthetics and opioids;
  • Pregnancy diseases (such as pregnancy-induced hypertension, preeclampsia or gestational diabetes, etc.);
  • Known fetal abnormalities or situations associated with an increased risk of cesarean section;
  • Patients who have taken opioids or sedatives within 4 hours before epidural analgesia.

Trial locations and contacts

1 site in 1 country.

China1 site, 1 recruiting
  • General hospital of Ningxia medical university

    Yinchuan, Ningxia, 750004

    xinli Ni, 86-0951-6743252, xinlini6@nyfy.com.cn

    Recruiting

Other trials in China

About this study

Official title: Observations on the Effect of Different Depths of Epidural Catheter Retention on the DPE Technique Combined With the PIEB Mode of Labor Analgesia:a Single-center, Prospective, Randomized Controlled Study

The purpose of this study is to observe the appropriate indwelling depth of epidural catheter when labor analgesia is performed in the mode of DPE combined with PIEB, and then shorten the onset time of labor analgesia and reduce the occurrence of catheter-related adverse outcomes.

Read the detailed description

In clinical practice, neuraxial analgesia is the most effective method for labor analgesia, including combined spinal-epidural (CSE) analgesia, dural puncture epidural (DPE) analgesia, and conventional epidural (EP) analgesia. Among them, DPE technology is an improvement of CSE technology. It means using a spinal needle to puncture the dura mater but not injecting drugs into the intrathecal space. Then, the epidural catheter is inserted into the epidural space. The punctured dura mater creates a new pathway for drug displacement from the epidural space to the subarachnoid space. In theory, compared with EP, DPE technology makes drugs enter the subarachnoid space more easily and can achieve a faster onset time of analgesia. At the same time, compared with CSE, the amount of drugs entering the subarachnoid space is not excessive, which can reduce the occurrence of adverse reactions such as itching and hypotension. At present, although there is controversy over the clinical advantages of DPE, its effectiveness has been confirmed in the article published by Gunaydin B et al. in 2019. In a series of RCT trials conducted by Professor Xu Zhendong's team in China, it is believed that the effect of DPE is related to the drug injection mode in the epidural space, the thickness of the puncture needle, and the distance between the drug outlet end and the puncture hole. At the same time, DPE technology combined with programmed intermittent epidural bolus (PIEB) mode seems to be a better choice in labor analgesia. Because the single drug bolus dose generated under the PIEB mode creates greater pressure in the epidural space, which is more conducive to drugs entering the subarachnoid space through the puncture hole. Based on the above research, when performing labor analgesia in the DPE combined with PIEB mode, we believe that the closer the opening of the epidural catheter is to the puncture hole, the easier it is for drugs to generate local pressure around the puncture hole and thus enter the subarachnoid space. This is related to the indwelling depth of the epidural catheter. The shorter the indwelling depth, the more drugs may enter the puncture hole, but it will also increase the probability of catheter detachment. The longer the indwelling depth, the farther the local pressure generated is from the puncture hole, and the advantage of the PIEB mode may be masked. At the same time, an excessively long indwelling depth will increase the incidence of unilateral block.

Conditions
Labor Analgesia
Being tested
The indwelling length of epidural catheter is 3 centimeters., The indwelling length of epidural catheter is 5 centimeters., The indwelling length of epidural catheter is 7 centimeters.
Keywords
Uterine contraction pain, Dural puncture epidural technique(DPE), Programmed intermittent epidural bolus(PIEB)

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The indwelling length of epidural catheter is 3 centimeters.Procedure or surgery

    When performing Dural Puncture Epidural technique with Programmed Intermittent Epidural Bolus(PIEB) mode for labor analgesia, According to different indwelling lengths of epidural catheters as variables, patients are divided into three treatment groups(3cm group 、5cm group and 7cm group)

  • The indwelling length of epidural catheter is 5 centimeters.Procedure or surgery

    When performing Dural Puncture Epidural technique with Programmed Intermittent Epidural Bolus(PIEB) mode for labor analgesia, According to different indwelling lengths of epidural catheters as variables, patients are divided into three treatment groups(3cm group 、5cm group and 7cm group)

  • The indwelling length of epidural catheter is 7 centimeters.Procedure or surgery

    When performing Dural Puncture Epidural technique with Programmed Intermittent Epidural Bolus(PIEB) mode for labor analgesia, According to different indwelling lengths of epidural catheters as variables, patients are divided into three treatment groups(3cm group 、5cm group and 7cm group)

Study groups in NCT06602440
Study groupRoleWhat they receive
3cm groupOtherWhen performing Dural Puncture Epidural technique with Programmed Intermittent Epidural Bolus(PIEB) mode for labor analgesia, the indwelling depth of the epidural catheter is 3 centimeters.
Receives: Procedure: The indwelling length of epidural catheter is 3 centimeters.
5cm groupOtherWhen performing Dural Puncture Epidural technique with Programmed Intermittent Epidural Bolus(PIEB) mode for labor analgesia, the indwelling depth of the epidural catheter is 5 centimeters.
Receives: Procedure: The indwelling length of epidural catheter is 5 centimeters.
7cm groupOtherWhen performing Dural Puncture Epidural technique with Programmed Intermittent Epidural Bolus(PIEB) mode for labor analgesia, the indwelling depth of the epidural catheter is 7 centimeters.
Receives: Procedure: The indwelling length of epidural catheter is 7 centimeters.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time of satisfactory analgesia.

    The time when the NRS score is less than 3 after the first administration during labor analgesia with DPE combined with PIEB mode.

    Measured: First dose in the epidural space to NRS score being less than 3.

  2. Consumption of ropivacaine per unit time.

    The consumption of ropivacaine per unit time during the entire labor analgesia process.

    Measured: First dose in the epidural space to the end of the third stage of labor.

Secondary outcomes (4)
  1. Related adverse outcomes.

    Occurrence of epidural catheter prolapse, itching, nausea, vomiting, hypotension and unilateral block.

    Measured: First dose in the epidural space to the end of the third stage of labor.

  2. Anesthesia level and lower limb motor block.

    Use the needle prick method to measure the anesthesia level and lower limb motor block after satisfactory labor analgesia.

    Measured: When labor analgesia is satisfactory.

  3. Duration of labor.

    Duration of the first, second, and third stages of labor.

    Measured: From the onset of labor to its end.

  4. Changes in fetal heart rate and uterine contraction pressure.

    Observe the changes in fetal heart rate and uterine contraction pressure before and after labor pain.

    Measured: Before and after labor pain.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Sep 2024
  2. Study start1 Jul 2024
  3. Primary completion1 Oct 2024 (estimated)
  4. Study completion1 Oct 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Single group
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
102 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06602440
Sponsor's protocol ID
Peng Liu-2024-2
Status last verified
Jul 2024
First submitted
17 Sep 2024
Last updated
19 Sep 2024
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Liu P, Chen Y, Ma P, Qin R, Shi Y, Ni X. Appropriate length of epidural catheter in epidural space for labour analgesia with dural puncture epidural combined with programmed intermittent epidural bolus. BMC Anesthesiol. 2026 Jan 20;26(1):123. doi: 10.1186/s12871-026-03637-x.

    PubMed 41559579

Questions about this trial

What is this clinical trial studying?

A study testing The indwelling length of epidural catheter is 3 centimeters., The indwelling length of epidural catheter is 5 centimeters. and The indwelling length of epidural catheter is 7 centimeters. in people with Labor Analgesia, run by General Hospital of Ningxia Medical University at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 19 Sep 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact xinli Ni, MD (13909586966, xinlini6@nyfy.com.cn), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time of satisfactory analgesia. (time frame: First dose in the epidural space to NRS score being less than 3.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06602440, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Sep 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in