Outcomes of High vs Physiological Intraocular Pressure During Cataract Surgery Using ACTIVE SENTRY

A study testing Cataract surgery with Active Sentry and Traditional cataract surgery in people with Cataract and Cataract Surgery, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Cataract surgery is a widely performed procedure across the world that helps restore vision in many patients suffering from cataracts. Irrigation is an essential component of the surgery. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Cataract, Cataract Surgery, Cataract Bilateral
What is being tested?
Cataract surgery with Active Sentry and Traditional cataract surgery
Could I receive a placebo?
No, everyone receives an active treatment
How many people
31 participants
Where
1 siteCanada
Study dates
1 Jan 2025to 31 Mar 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • No prior ocular surgery including corneal refractive surgery
  • Bilateral visually significant cataract, similar in density (LOCS III grade 2+), undergoing uncomplicated cataract surgery
  • Equal dilated pupil size ≥6mm, no use of pupil expansion devices
  • Axial length 21-26mm, refractive error between -8.00D to +6.00D and cylinder ≤ 4.50D, normal K values <48.00D
  • Normal CCT range 540µm ± 50

Who cannot join

  • History of corneal disease or dystrophies
  • Media opacification for reasons other than cataract
  • Compromised zonular integrity or stability.
  • Retinal and retinal vascular pathologies, age-related macular degeneration
  • Glaucoma
  • Patients with uncontrolled systematic diseases, including hypertension, diabetes, systemic cardiovascular diseases, and hematological diseases.

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • Centre Hospitalier de l'Université de Montréal

    Montreal, Quebec

Other trials in Canada

About this study

Cataract surgery is a widely performed procedure across the world that helps restore vision in many patients suffering from cataracts. Irrigation is an essential component of the surgery. Fluid is constantly circulated to help regulate temperature as heat is generated with ultrasound energy, to minimize tissue trauma, and to create an intraocular pressure (IOP) sufficient to keep the anterior chamber (AC) stable. In parallel, aspiration brings the components of the cataract closer to the surgical instrument. A balance between irrigation and aspiration during surgery is essential to maintain stability in the AC. However, an ideal flow rate, which influences IOP during surgery, is yet to be determined. Most recent studies with Centurion Active Sentry show that there is similar efficiency between higher and lower IOP settings. Traditionally, high-flow rates have been used in advanced cataracts and are believed to make space in the AC. However, they are known to create fluid turbulence and are associated with risks of tissue damage, including cell loss in one of the cornea's layers. High IOP during surgery has also been shown to cause damage to the optic nerve as well as to the retina. Distorting and stretching the AC during phacoemulsification have also been associated with increased pain experienced by the patient. Comfort can be achieved by lowering pressure levels. Low-flow rates have a better safety profile, reduce IOP and pressure fluctuations while offering equal efficiency, including comparable surgical time. Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively as opposed to patients in the high-flow rates. As less fluid turbulence is created with low-flow rates, there is decreased risk of fragment contact with the cornea's inner surface, thus reducing cell loss. Alcon Laboratories, Inc. developed Active Fluidics which allows to stabilize intraocular pressure and prevent IOP fluctuations as well as IOP surges during surgery. It is now further equipped with the Active Sentry handpiece which is integrated to the surgical instrument and acts as a sensor to pressure variation. It allows rapid feedback to maintain a stable AC. Our research project aims to assess the outcomes following phacoemulsification done with physiological IOP with the help of the Active Sentry handpiece compared to traditional high IOP levels.

Read the detailed description

Cataract surgery is a widely performed procedure across the world that helps restore vision in many patients suffering from cataracts. The surgery has known many improvements across time and continues to do so. Irrigation is an essential component of the surgery. Fluid is constantly being circulated to help regulate temperature as heat is generated with the use of ultrasound energy, to minimize tissue trauma, and to create an intraocular pressure sufficient to keep the anterior chamber stable. In parallel, aspiration brings the components of the cataract closer to the surgical instrument. A balance between irrigation and aspiration during surgery is essential to maintain stability in the anterior chamber. However, an ideal flow rate, which influences intraocular pressure (IOP) during surgery, is yet to be determined. Most recent studies with Centurion Active Sentry (maintaining vacuum and aspiration rates the same) show that there is similar efficiency between higher and lower IOP settings. Traditionally, high-flow rates have been used in advanced cataracts and are believed to increase the space in the anterior chamber. However, they are known to create fluid turbulence and are associated with risks of tissue damage, including cell loss in the endothelial layer of the cornea. High intra-ocular pressure during surgery has also been shown to cause damage to the optic nerve as well as to the retina. Distorting and stretching the anterior chamber during phacoemulsification have also been associated with increased pain experienced by the patient. Comfort can be achieved by lowering pressure levels. Low-flow rates have a better safety profile, reduce IOP and pressure fluctuations while offering equal efficiency, including comparable surgical time. Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively while patients in the high-flow rates show signs of corneal damage as well as greater anterior segment inflammation. As less fluid turbulence is created with low-flow rates, there is decreased risk of fragment contact with the cornea's inner surface, thus reducing cell loss. Alcon Laboratories, Inc. developed Active Fluidics which allows to stabilize intraocular pressure and prevent IOP fluctuations as well as IOP surges during surgery. It is now further equipped with the Active Sentry handpiece which is integrated to the surgical instrument and acts as a sensor to pressure variation. It allows rapid feedback to maintain a stable anterior chamber. Our research project aims to assess the outcomes following phacoemulsification done with physiological IOP with the help of the Active Sentry handpiece compared to traditional high IOP levels.

Being tested
Cataract surgery with Active Sentry, Traditional cataract surgery
Keywords
Active Sentry, cataract surgery, cataracts, High intra-ocular pressure, central corneal thickness, intraocular pressure, phacoemulsification, safety profile, physiological IOP
Medical subject headings
Cataract

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Cataract surgery with Active SentryDevice

    Surgical instrument that detects changes in intraocular pressure and allows rapid feedback to stabilize pressure during cataract surgery.

  • Traditional cataract surgeryProcedure or surgery

    Cataract surgery performed with high intraocular pressures

Study groups in NCT06611670
Study groupRoleWhat they receive
Cataract surgery with Active SentryExperimentalCataract surgery with low IOP values (32mmHg)
Receives: Device: Cataract surgery with Active Sentry
High IOPActive comparatorCataract surgery with high IOP (60mmHg) which is the average pressure at which cataract surgery is being performed currently
Receives: Procedure: Traditional cataract surgery

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Central corneal thickness at 1 day postoperatively

    Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively. CCT will be measured using a pachymetry (Normal CCT range 540µm ± 50).

    Measured: 1 day postoperatively

Secondary outcomes (5)
  1. Volume of balanced salt solution used during surgery

    Volume of balanced salt solution as measured by the Active Sentry Centurion machine

    Measured: During surgery

  2. Total ultrasound time and total aspiration time

    Total ultrasound time and total aspiration time as measured by the Active Sentry Centurion machine

    Measured: During surgery

  3. Endothelial cell loss (inner surface of the cornea)

    Endothelial cell count measured by specular microscopy

    Measured: At month 1 and month 3 postoperatively.

  4. Central corneal thickness

    Using central corneal thickness (CCT) as an indicator of corneal trauma, it has been shown that patients that have had surgery with low-flow rates present no change in the CCT postoperatively. CCT will be measured using a pachymetry (Normal CCT range 540µm ± 50).

    Measured: 1 week, 1 month and 3 months postoperatively

  5. Corneal clarity

    Measured uring the Pentacam corneal densitometry

    Measured: Day 1, week 1, month 1 and month 3 postoperatively

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Sep 2024
  2. Study start1 Jan 2025
  3. Primary completion31 Mar 2026
  4. Study completion31 Mar 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Interventional single-masked pair-eye design clinical trial, single-center, single-surgeon. Eyes will be block-randomized as to which surgery they will receive first (high vs low IOP phacoemulsification). 62 eyes of 31 patients will be included in this study. For each patient, one eye will be randomized to receive phacoemulsification with high IOP (Group 1), and the other eye will receive phacoemulsification with physiological IOP (Group 2). This way, each patient will receive both treatments, one for each eye, which will allow us to do paired analyses.
Masking
Triple blind
Who is masked
Participant, Investigator, Outcomes assessor
Enrolment
31 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06611670
Sponsor's protocol ID
2025-11959
Other IDs
2025
Acronym
ACTIVESENTRY
Status last verified
Aug 2026
First submitted
22 Sep 2024
Last updated
14 Aug 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Zhao Y, Li X, Tao A, Wang J, Lu F. Intraocular pressure and calculated diastolic ocular perfusion pressure during three simulated steps of phacoemulsification in vivo. Invest Ophthalmol Vis Sci. 2009 Jun;50(6):2927-31. doi: 10.1167/iovs.08-2996. Epub 2009 Jan 24.

    PubMed 19168897
  • Vasavada AR, Praveen MR, Vasavada VA, Vasavada VA, Raj SM, Asnani PK, Garg VS. Impact of high and low aspiration parameters on postoperative outcomes of phacoemulsification: randomized clinical trial. J Cataract Refract Surg. 2010 Apr;36(4):588-93. doi: 10.1016/j.jcrs.2009.11.009.

    PubMed 20362850

Questions about this trial

What is this clinical trial studying?

A study testing Cataract surgery with Active Sentry and Traditional cataract surgery in people with Cataract and Cataract Surgery, run by Centre hospitalier de l'Université de Montréal (CHUM) at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 14 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Central corneal thickness at 1 day postoperatively (time frame: 1 day postoperatively). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06611670, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Aug 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in