Comparison of 3 RF Delivery Modes of the QDOT Catheter for Paroxymal Atrial Fibrillation (AF) Ablation

A study testing Q-MODE : radiofrequency ablation up to 50W, Q-MODE+ : radiofrequency up to 90W and Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior part in people with Atrial Fibrillation, run by Institut Mutualiste Montsouris at 1 site in France.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Pulmonary vein isolation is the main treatment of paroxysmal and persistent atrial fibrillation. The aim of our study is to prospectively compare the efficacy and safety of the 3 options of radiofrequency delivery with QDOT Micro™, with systematic use of catheter stabilization tools and tighter lesions Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Atrial Fibrillation
What is being tested?
Q-MODE : radiofrequency ablation up to 50W, Q-MODE+ : radiofrequency up to 90W and Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior part
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
90 participants
Where
1 siteFrance
Study dates
Oct 2024to Oct 2028
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient aged 18 or over
  • First atrial fibrillation ablation
  • Paroxysmal atrial fibillation defined as atrial fibrillation lasting less than 48 hours
  • Early atrial fibrillation defined as atrial fibrillation lastiing between 7 days and 3 months
  • At least one episode of atrial fibrillation in the year preceding study entry
  • Patient affiliated to a health insurance

Who cannot join

  • History of atrial fibrillation ablation (surgery or catheter)
  • Documented left atrial thrombus
  • Left atrial (LA) diameter > 60mm / LA area > 35cm2 / Left atrial volulme index (LAVI) > 45ml/m2
  • N/STEMI replacement or angioplasty or valve within 3 months prior to registration
  • Any contraindication mentioned in the instructions for use of the QDOT MICRO™ bidirectional navigation catheter
  • Patient unable to understand study information
  • Patient deprived of liberty by judicial or administrative decision

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Naly ANDRIAMBAO contact

+33156616439

naly.andriambao@imm.fr

France1 site, 1 recruiting
  • Institut Mutualiste Montsouris

    Paris, Paris, 75014

    Frederic SEBAG, +33156616263, frederic.sebag@imm.fr

    Recruiting

Other trials in France

About this study

Official title: Comparison of 3 RF Delivery Modes of the QDOT Catheter for Paroxymal AF Ablation: a Prospective Study

Pulmonary vein isolation is the main treatment of paroxysmal and persistent atrial fibrillation.

The aim of our study is to prospectively compare the efficacy and safety of the 3 options of radiofrequency delivery with QDOT Micro™, with systematic use of catheter stabilization tools and tighter lesions

Read the detailed description

Pulmonary vein isolation (PVI) is the main treatment of paroxysmal and persistant atrial fibrillation.

PVI is achieved by point-by-point radiofrequency ablation that creates flexible lesion set within targeted area.

PVI using standard ablation catheter with limited power (50W) have been described in case series with favorable efficacy and safety.

QDOTMicro™ is a radiofrequency ablation catheter that incorporates advanced, high-energy ablation, improved temperature monitoring, optimized irrigation, and higher signal resolution.

QDOT Micro™ provides several options regarding radiofrequency administration :

  • Q-MODE : provides high power short duration (HPSD) unitl 50W radiofrequency,
  • Q-MODE+ : provides very high power very short duration (vHSPD) until 90W radiofrequency,
  • Hybrid Q-MODE/Q-MODE+ : is a combination of two methods. In our experience, stability is a prerequisite for PVI with QDOT Micro™.

Small series have described encouraging results (85% isolation, unpublished data) with stabilization tools such as low-volume ventilation or apnea, high-rate simualtion, Vizigo bi-directional sheath (Vizigo™).

Recently, preliminary animal data argue in favor or reducing the interpoint distance with QDOT™.

To date, there is no study comparing the 3 options of radiofrequency delivery. The aim of our study is to prospectively compare the efficacity and safety of the 3 options of radiofrequency delivery with QDOT Micro™, with systematic use of catheter stabilization tools and tighter lesions.

The same device is used in all three randomisation groups. The difference between the intervention is the intensity of the radiofrequency applied.

Being tested
Q-MODE : radiofrequency ablation up to 50W, Q-MODE+ : radiofrequency up to 90W, Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior part
Medical subject headings
Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Q-MODE : radiofrequency ablation up to 50WProcedure or surgery

    The same device (QDOT Micro™) is used in all 3 arms of this trial. The 3 strategies of radiofrequency delivery within the 3 arms are already used in the standard of care.

    For patient randomized in this arm, the device is set to Q-MODE option: the intensity of radiofrequency to isolate the pulmonary vein is limited to 50W.

  • Q-MODE+ : radiofrequency up to 90WProcedure or surgery

    The same device (QDOT Micro™) is used in all 3 arms of this trial. The 3 strategies of radiofrequency delivery within the 3 arms are already used in the standard of care.

    For patient randomized in this arm, the device is set to Q-MODE+ option: the intensity of radiofrequency to isolate the pulmonary vein is limited to 90W.

  • Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior partProcedure or surgery

    The same device (QDOT Micro™) is used in all 3 arms of this trial. The 3 strategies of radiofrequency delivery within the 3 arms are already used in the standard of care.

    For patient randomized in this arm, the device is set to "Q-MODE/Q-MODE+" option: the intensity of radiofrequency delivered to isolate the pulmonary vein is limited to 50W in the anterior part and to 90W in the posterior part.

Study groups in NCT06647251
Study groupRoleWhat they receive
Q-MODEActive comparatorRadiofrequency ablation with High Power - Short Duration (HPSD) up to 50W.
Receives: Procedure: Q-MODE : radiofrequency ablation up to 50W
Q-MODE+Active comparatorRadiofrequency ablation with High Power - Short Duration (HPSD) up to 90W.
Receives: Procedure: Q-MODE+ : radiofrequency up to 90W
Hybride Q-MODE/Q-MODE+Active comparatorA combination of the two ablation methods.
Receives: Procedure: Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior part

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Incidence of primary adverse events related to the ablation procedure

    Incidence of primary adverse events within 7 days after ablation in the 3 arms

    Measured: 7 days after ablation

  2. Acute procedural success

    Acute procedural success is defined as electrical isolation of all pulmonary veins

    Measured: At the end of the ablation procedure

Secondary outcomes (18)
  1. Incidence of serious adverse event

    Incidence of serious adverse events

    Measured: within 7 days (early onset), 7 to 30 days (periprocedural), up to 18 months (late onset) of the ablation procedure

  2. Rate of additional lesions

    Rate of additional lesions between all targeted veins and per subject

    Measured: At the end of the ablation procedure

  3. Location of additional lesions

    Anatomical location of additional lesions

    Measured: At the end of the ablation procedure

  4. Use of another catheter

    Use of another catheter than QDOT in all targeted veins

    Measured: At the end of the ablation procedure

  5. Time spent in operating room

    Time spent in operating room

    Measured: At the end of the ablation procedure

  6. Skin-to-skin time

    Skin-to-skin time

    Measured: At the end of the ablation procedure

  7. Glove-to-glove time

    Glove-to-glove time = total procedure time

    Measured: At the end of the ablation procedure

  8. Mapping time

    Mapping time

    Measured: At the end of the ablation procedure

  9. Total ablation time

    Total ablation time

    Measured: At the end of the ablation procedure

  10. Left vein ablation time

    Left vein ablation time

    Measured: At the end of the ablation procedure

  11. Right vein ablation time

    Right vein ablation time

    Measured: At the end of the ablation procedure

  12. Number of radiofrequency applications

    Number of radiofrequency applications

    Measured: At the end of the ablation procedure

  13. Number of vHPSD radiofrequency applications

    Number of vHPSD (very High Power Short Duration) radiofrequency applications

    Measured: At the end of the ablation procedure

  14. Number of HPSD radiofrequency applications

    Number of HPSD (High Power Short Duration) radiofrequency applications

    Measured: At the end of the ablation procedure

  15. Temperature

    Temperature

    Measured: At the end of the ablation procedure

  16. Power

    Power

    Measured: At the end of the ablation procedure

  17. Contact force

    Contact force

    Measured: At the end of the ablation procedure

  18. Impedance

    Impedance

    Measured: At the end of the ablation procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Oct 2024
  2. Study startOct 2024 (estimated)
  3. Primary completionOct 2027 (estimated)
  4. Study completionOct 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Patients will be randomly assigned to one of the following arms: Q-MODE, Q-MODE+, hybride Q-MODE/Q-MODE+. The number of patients in each arm is the same.
Masking
None (open label)
Enrolment
90 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06647251
Sponsor's protocol ID
RYTHMO-03-2024
Acronym
QDOT
Status last verified
Oct 2024
First submitted
27 Aug 2024
Last updated
17 Oct 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Q-MODE : radiofrequency ablation up to 50W, Q-MODE+ : radiofrequency up to 90W and Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior part in people with Atrial Fibrillation, run by Institut Mutualiste Montsouris at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 17 Oct 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Naly ANDRIAMBAO (+33156616439, naly.andriambao@imm.fr), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Incidence of primary adverse events related to the ablation procedure (time frame: 7 days after ablation). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Oct 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in