AzTrials
AzTrials

Full-arch ImpressionNCT06658366

The Accuracy of Intraoral Scanning Systems for Full-Arch Impressions Is Examined in 10 Participants

A study testing impression of the teeth in people with Full-arch Impression, run by University of Zurich at 1 site in Switzerland.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

For several decades now, modern procedures have allowed dentists to capture your teeth using digital cameras. This digital procedure is increasingly replacing traditional impressions with a viscous mass that hardens in the mouth. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Full-arch Impression
What is being tested?
impression of the teeth
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10 participants
Where
1 siteSwitzerland
Study dates
28 Oct 2024to 30 Apr 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • All genders, minimum age for participation is 18 years
  • Good general health and healthy dental conditions (gaps with a maximum of 1 missing tooth are permitted)
  • Written consent after informed consent discussion is available

Who cannot join

  • participants under the age of 18
  • Addicts or participants with impaired cognitive abilities that do not allow the participant to assess the scope of the study
  • participants suffering from periodontitis (pathological tooth mobility could falsify the study results)
  • Maximal mouth opening less than 3.5 cm
  • participants who wear large reconstructive works and/or have a free-end situation from at least the 2nd premolar

Trial locations and contacts

1 site in 1 country.

Switzerland1 site
  • University of Zurich, Center for Dental Medicine

    Zurich, 8032

Other trials in Switzerland

About this study

Official title: In Vivo Accuracy of Digital Intraoral Scans/Optical Impression Systems for the Production of Full-Arch Impressions

For several decades now, modern procedures have allowed dentists to capture your teeth using digital cameras. This digital procedure is increasingly replacing traditional impressions with a viscous mass that hardens in the mouth.

In the following study, the investigators want to find out whether the accuracy of these modern methods is comparable to the classic impression technique.

Three conventional impressions are taken for this purpose, and multiple digital impressions are also taken with each of the intraoral scanners. The impressions are then compared with each other. This allows the accuracy of the different intraoral scanners to be determined.

Read the detailed description

In summary, this study intends to address the need for comprehensive in vivo research on the accuracy of intraoral impression methods, especially in the context of modern digital technologies. By comparing various digital and conventional methods, this research will offer valuable information to guide dental practitioners in choosing the most precise and reliable techniques for their clinical applications.

The following study design is planned:

The study is non-randomised. The study setup is monocentric. At the beginning of the session, 3 conventional impression each of the upper and lower jaw is taken. After 8 hours the impression is moulded by a dental technician with a SuperHard plaster (type 4).After 48 hours of setting time the plaster-model is scanned with a lab scanner (inEos X5, Dentsply Sirona) to generate a .stl-file that is comparable to the following digital impressions.

This is followed by 6 digital impressions of the upper and lower jaw and the associated bite registration in habitual occlusion, divided between two experienced practitioners (3 upper, 3 lower jaw scans, 3 bite registrations per practitioner) with the 8 different intra oral scanners. In total, 6 conventional (3 upper, 3 lower jaw impressions), 48 digital impressions and 48 bite registration are taken. If it is not possible to take all the impressions in one session, a new conventional impression is taken at the start of each new session, so that a daily updated reference model is always available. Minimizing bias is achieved, by using the intra oral scanners according to the manufacturers instructions.

The number of scans was calculated as part of a power analysis based on previous study results and should therefore be meaningful.

The selection of scanners represents a heterogeneous selection of devices currently on the market. The scanners come from different price categories and use different optical measuring principles.

The precision measurement is carried out by comparing the impressions within and between the tested groups (precision and trueness respectively). For that, the scans will be exported to STL \& PLY format (depending on the scanning device) and imported into evaluation programs (Dentexion, Dentexion and Control X, Geomagic). The evaluation process follows the ISO 5725-1 criteria. After superimposition of the mesh surfaces according to the best-fit alignment, the distances will be measured point-to-point using the signed nearest neighbor method and sorted into a histogram. From that, the distance measure for each pairwise surface superimposition will be calculated from the (90%-10%)/2 percentile value.

Being tested
impression of the teeth
Keywords
accuracy, intra oral scan, full-arch impression, conventional and optical impression of the teeth

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • impression of the teethDiagnostic test

    Only conventional and digital impressions (comparable with taking videography) are taken of the patients teeth.

Study groups in NCT06658366
Study groupRoleWhat they receive
Comparison conventional impression vs. digital impressionOtherThe investigators would like to investigate the accuracy of various intraoral scanning systems. For this a conventional impression is taken from all patients to generate a reference model, which is then compared to full-arch impressions from various digital intraoral scanning systems. The examination is carried out in the same way for all participants.
Receives: Diagnostic Test: impression of the teeth

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy measurement of digital impressions performed with optical impression systems are primary endpoints

    The accuracy of the intraoral scanners (primary endpoint) is analyzed on the basis of precision and trueness. The unit of measure used is the same (μm).

    The trueness of each test group is assessed by superimposing each scan with the reference model data set. The precision is calculated as the mean difference between all superimpositions within one test group.

    Measured: It is intended that all impressions take place within half a day, the accuracy measurement should be carried out within 6 weeks.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Oct 2024
  2. Study start28 Oct 2024
  3. Primary completion30 Apr 2025
  4. Study completion30 Apr 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
10 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06658366
Sponsor's protocol ID
2024-00618
Status last verified
Jun 2025
First submitted
25 Jul 2024
Last updated
26 Jan 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: The ethics application, which has already been approved, contains clear provisions on data protection. There is no provision for data to be passed on; accordingly, the investigators must protect all personal data and may not pass it on to third parties.

Publications

  • Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent. 2016 Mar;115(3):313-20. doi: 10.1016/j.prosdent.2015.09.011. Epub 2015 Nov 6.

    PubMed 26548890

Questions about this trial

What is this clinical trial studying?

A study testing impression of the teeth in people with Full-arch Impression, run by University of Zurich at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 26 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy measurement of digital impressions performed with optical impression systems are primary endpoints (time frame: It is intended that all impressions take place within half a day, the accuracy measurement should be carried out within 6 weeks.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06658366, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Jan 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in