Laparoscopic SurgeryNCT06688097

Ultrasound-Guided Esophageal Compression During Adult Mask Ventilation

A study testing Compression of esophageal in people with Laparoscopic Surgery and Ultrasonography, run by Liu Han at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

A total of 103 elective surgery patients who met the inclusion criteria were selected. After screening for eligibility according to the inclusion and exclusion criteria and signing informed consent, they were randomly divided into two groups. Read more about this study

Who is it for?
Ages 18 to 65 years
What is being tested?
Compression of esophageal
Could I receive a placebo?
No, everyone receives an active treatment
How many people
103 participants
Where
1 siteChina
Study dates
25 Sep 2024to 31 Dec 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age 18 to 65 years
  • American Society of Anesthesiologists (ASA) Physical Status Classification I-II.
  • Body Mass Index (BMI) between 18 and 28 kg/m².
  • Patients undergoing elective tracheal intubation for general anesthesia.
  • Patients scheduled for laparoscopic surgery.
  • Fasting for ≥8 hours and abstaining from liquids for ≥2 hours before surgery, with low risk of gastroesophageal regurgitation and aspiration.

Who cannot join

  • Suspected difficult FMV (e.g., age >55 years, BMI >26 kg/m², edentulous, history of snoring, and long beard; presence of two or more factors).
  • Pre-existing respiratory, pharyngeal, laryngeal, facial, or neck pathology.
  • History of gastrointestinal surgery, gastroesophageal reflux disease (GERD), or high risk of aspiration.
  • Severe cardiac, cerebral, pulmonary, hepatic, or renal diseases.
  • Patients requiring non-invasive ventilation prior to surgery.
  • Patients currently participating in other clinical trials or who refuse to participate.

Trial locations and contacts

1 site in 1 country.

China1 site
  • Nanjing First Hospital

    Nanjing, Jiangsu, 210006

Other trials in China

About this study

Official title: Ultrasound-Guided Esophageal Compression During Adult Mask Ventilation: A Prospective Observational Study

A total of 103 elective surgery patients who met the inclusion criteria were selected. After screening for eligibility according to the inclusion and exclusion criteria and signing informed consent, they were randomly divided into two groups. Upon entering the operating room, routine ECG monitoring was initiated, and a peripheral vein was opened. Ultrasound was used to measure the baseline cross-sectional area (CSA) of the gastric antrum in the supine position. After general anesthesia induction, positive pressure ventilation was applied via face mask. Group A received no external compression, while Group B underwent esophageal compression under ultrasound guidance.

Read the detailed description

Upon entering the operating room, intravenous access is established, and oxygen is administered. Standard vital sign monitoring is initiated, including heart rate, non-invasive blood pressure, peripheral oxygen saturation, temperature monitoring, and BIS monitoring. Ultrasound is used to measure the cross-sectional area (CSA) of the gastric antrum before the onset of FMV.

Oxygen is administered via face mask for denitrogenation, with 100% pure oxygen (6 L/min flow rate). Intravenous medications are sequentially administered: midazolam 0.03 mg/kg, propofol 1-2 mg/kg, sufentanil 0.5 μg/kg, remifentanil 1 μg/kg, and rocuronium bromide 0.6 mg/kg. After the patient loses consciousness and the eyelash reflex is absent, FMV is initiated. The trial employs a pressure-controlled ventilation (PCV) mode with a pressure of 18 cmH2O, a level sufficient to provide adequate alveolar ventilation while staying below the threshold for significant gastroesophageal regurgitation. The respiratory rate is set at 14 breaths per minute with an inspiration-to-expiration ratio of 1:2.

After three minutes of FMV, the gastric antrum CSA is measured again in supine, semi-recumbent, and right lateral decubitus positions. Video laryngoscopy is used to record POGO scores before and after ultrasound-guided esophageal compression, and after 4 minutes of ventilation, tracheal intubation is performed. Grouping:

Group A (Control Group): No esophageal compression is applied, and FMV is performed for 4 minutes.

Group B (Intervention Group): Ultrasound-guided esophageal compression plus FMV: before the start of FMV, ultrasound is used to locate the esophagus, and pressure is applied to the esophagus at the cricoid level to collapse the esophageal lumen. Esophageal pressure is released just before tracheal intubation following 4 minutes of ventilation.

Being tested
Compression of esophageal
Medical subject headings
Gastric Dilatation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Compression of esophagealBehavioural

    Before the start of FMV, ultrasound is used to locate the esophagus, and pressure is applied to the esophagus at the cricoid level to collapse the esophageal lumen. Esophageal pressure is released just before tracheal intubation following 4 minutes of ventilation.

Study groups in NCT06688097
Study groupRoleWhat they receive
Group A (Control Group)No interventionNo esophageal compression is applied, and FMV is performed for 4 minutes.
Group B (Intervention Group)ExperimentalUltrasound-guided esophageal compression plus FMV: before the start of FMV, ultrasound is used to locate the esophagus, and pressure is applied to the esophagus at the cricoid level to collapse the esophageal lumen. Esophageal pressure is released just before tracheal intubation following 4 minutes of ventilation.
Receives: Behavioral: Compression of esophageal

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The incidence of gastric distension

    Defined as a significant increase in gastric antrum CSA with acoustic shadowing or the characteristic "comet-tail sign," or when the enlarged gastric antrum obstructs the surgical field

    Measured: During anesthesia induction

Secondary outcomes (8)
  1. The positional relationship between the esophagus and trachea

    Observe the position of the esophagus relative to the trachea without the application of pressure on the patient, and assess whether there is any positional change of the esophagus relative to the trachea under ultrasound guidance after esophageal compression, ensuring the accuracy and safety of esophageal compression.

    Measured: Before anesthesia induction

  2. Tidal volume

    Observe whether tidal volume is affected after ultrasound-guided esophageal compression and evaluate the impact of esophageal compression on ventilation quality. Effective esophageal compression should maintain a tidal volume of no less than 6 ml/kg for the patient.

    Measured: During anesthesia induction

  3. Oxygen saturation

    Observe whether oxygen saturation is affected after ultrasound-guided esophageal compression and evaluate the impact of esophageal compression on ventilation quality. Effective esophageal compression should maintain the patient's oxygen saturation at no less than 95%.

    Measured: During anesthesia induction

  4. Airway plateau

    Observe the values of airway plateau pressure during esophageal compression to evaluate the mechanical impact of esophageal compression on the airway. An airway plateau pressure not exceeding 20-25 cmH₂O indicates effective esophageal compression.

    Measured: During anesthesia induction

  5. The percentage of glottic opening (POGO) score

    The percentage of glottic opening (POGO) score represents the portion of the glottis visualized. It is defined anteriorly by the anterior commissure and posteriorly by the interarytenoid notch. The score ranges from 0% when none of the glottis is seen to 100% when the entire glottis including the anterior commissure is seen.

    A POGO score of 100% denotes visualization of the entire glottic opening in linear fashion from the anterior commissure to the posterior cartilages . If none of the glottic opening is seen, then the POGO score is 0%. The higher the POGO value, the less impact effective esophageal compression has on ventilation performance.

    Measured: During tracheal intubation, immediately

  6. Surgeon's evaluation of gastric insufflation

    The degree of gastric distention is assessed by the same surgeon through laparoscopy. A score of 0 is given when there is no significant gastric distention, a score of 1 is given when there is noticeable gastric distention that does not affect the surgical procedure, and a score of 2 is given when there is significant gastric distention that affects the surgery, requiring the placement of a gastric tube for decompression. The number of postoperative vomiting episodes is recorded: 0 episodes is scored as 0, 1-2 episodes is scored as 1, and more than 2 episodes is scored as 2. A lower score indicates better esophageal compression effectiveness.

    Measured: Upon the start of surgery, immediately

  7. Rate of esophageal diameter change

    Compare the diameter before and after esophageal compression and calculate the percentage change in diameter. After esophageal compression, the diameter of the esophagus should decrease. The percentage change in diameter is usually expressed as a negative value, indicating that the esophagus has constricted after compression. If the percentage change is positive, it suggests that the compression effect is not ideal, and the esophagus may not have been effectively compressed.

    Measured: During anesthesia induction

  8. Esophageal compression pressure

    Recording esophageal compression pressure can ensure that the applied pressure is within an effective range, help understand the relationship between compression intensity and ventilation efficacy, and promptly identify potential complications, such as airway compression or esophageal injury caused by excessive pressure, allowing for necessary interventions.

    Measured: During anesthesia induction

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Nov 2024
  2. Study start25 Sep 2024
  3. Primary completion12 Sep 2025
  4. Study completion31 Dec 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Masking
Triple blind
Who is masked
Participant, Care provider, Outcomes assessor
Enrolment
103 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06688097
Sponsor's protocol ID
KY20240924-01
Status last verified
Apr 2026
First submitted
15 Oct 2024
Last updated
24 Apr 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Compression of esophageal in people with Laparoscopic Surgery and Ultrasonography, run by Liu Han at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 24 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The incidence of gastric distension (time frame: During anesthesia induction). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Apr 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in