Advanced Wireless Sensors for Neonatal Care in the Delivery Room

A study testing Wireless skin sensors vital sign monitoring system and Wired vital sign monitoring system in people with Sudden Unexplained Infant Death and Apnea of Newborn, run by Guilherme Sant'Anna, MD at 5 sites in 4 countries.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

The goals of this observational study is to assess whether a new advanced wireless skin sensor vital sign monitoring system can effectively monitor the vital signs of healthy newborn infants (≥ 35 weeks gestational age). The main aims of this Study are to: 1. Assess feasibility 2. Evaluate safety 3. Read more about this study

Who is it for?
Ages 35 to 42 weeksHealthy volunteers can take part
What is being tested?
Wireless skin sensors vital sign monitoring system and Wired vital sign monitoring system
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
600 participants
Where
5 sitesin 4 countries
Study dates
8 Apr 2025to 30 Dec 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 35 to 42 weeks
  • All sexes
  • Healthy volunteers accepted
  • Child

Who may be able to join

  • Newborns ≥35 weeks (gestational age)
  • Newborns determined to be clinically stable at delivery
  • Newborns with no skin abnormalities

Who cannot join

  • Newborns ≤ 35 weeks (gestational age)
  • Newborns determined to not be clinically stable at delivery
  • Newborns with Skin abnormalities

Trial locations and contacts

5 sites in 4 countries. Contact the study team or a site near you to ask about taking part.

5 sites in 4 countries

Canada2 sites, 2 recruiting
  • Montreal Children's Hospital

    Montreal, Quebec, H4A 3J1

    Guilherme Sant'Anna, MD, 1-514-412-4400 ext. 23489, guilherme.santanna@mcgill.ca

    Guilherme Sant'Anna, MD

    Recruiting
  • Royal Victoria Hospital

    Montreal, Quebec

    Guilherme Sant'Anna, MD, PhD

    Recruiting

Other trials in Canada

Brazil1 site, 1 recruiting
  • Hospital Universitário da Universidade Estadual de Londrina

    Londrina, Paraná, 86038-350

    Adriana Zani

    Not yet recruiting

Other trials in Brazil

Italy1 site, 1 recruiting
  • Nuovo Ospedale degli Infermi

    Ponderano, BI, 13875

    Paolo Manzoni, MD

    Not yet recruiting

Other trials in Italy

Switzerland1 site, 1 recruiting
  • Lucerne Cantonal Hospital

    Lucerne, Canton of Lucerne

    Urs Schumacher

    Not yet recruiting

Other trials in Switzerland

About this study

Official title: Advanced Wireless Sensors for Neonatal Care in the Delivery Room: the AWARD Prospective Multicenter International Study

The goals of this observational study is to assess whether a new advanced wireless skin sensor vital sign monitoring system can effectively monitor the vital signs of healthy newborn infants (≥ 35 weeks gestational age). The main aims of this Study are to:

  1. Assess feasibility
  2. Evaluate safety
  3. Determine accuracy of the wireless monitoring system, compared to the standard of care wired vital sign monitoring system, immediately after delivery and for the first 2h of age in the obstetrical center under unsupervised parents' care. The newborn infants participating in the Study will have both vital sign monitoring systems placed on their chest and limb. Their vital signs will be monitored for 2h consecutively.
Read the detailed description

When the transition from intrauterine to extrauterine life necessitates Neonatal Resuscitation, specialized monitoring of vital signs is required. Sudden Unexpected Postnatal Collapse (SUPC) is an apnea or cardiorespiratory failure occurring in otherwise healthy near-term or term neonates, usually in the first 48 hours of age, during the initial Kangaroo Mother Care (KMC) in the obstetrical center. SUPC carries a high morbidity and mortality rate. Approximately 10 million babies do not breathe immediately after birth, and 60% require basic resuscitation interventions. Sudden Unexpected Postnatal Collapse has been estimated to occur in 2.6-133 cases per 100.000 newborns and over 50% of the cases occur following accidental suffocation, which frequently goes unrecognised by parents in the obstetrical center during unsupervised KMC.

Current guidelines recommend monitoring of heart rate (HR), oxygen saturation (SpO2), and skin temperature (Tskin) during neonatal resuscitation. This is usually achieved by using wired electrodes and sensors that require expensive and large base units attached to a power supply. SUPC is a rare but largely preventable cause of neonatal mortality that deserves particular attention. Better resuscitation and prevention of SUPC might be achieved by continuous non-intrusive monitoring of vital signs immediately after delivery and while in the obstetrical center.

This research will address a very important gap in care; the need for safe and accurate advanced, non-invasive, and non-intrusive wireless technologies for monitoring of vital signs immediately after birth and during the immediate postnatal care, potentially preventing cases of SUPC while in the obstetrical center.

Reliable and low-cost wireless monitoring that could be used immediately after delivery would promote widespread adoption of neonatal resuscitation recommendations in low and middle income countries, improve detection of vital signs quickly after delivery and during early unsupervised KMC, and optimize neonatal care in the obstetrical centers or during hospital stay, to prevent cases of SUPC and its associated high mortality.

Being tested
Wireless skin sensors vital sign monitoring system, Wired vital sign monitoring system
Keywords
Delivery Room, Newborn, Neonatal Resuscitation, Wireless Technology, Vital Sign Monitoring, Sudden Unexplained Post-Natal Collapse, SUPC, Obstetrical Center, Obstetrics, Neonate, Birth, Birthing Center, C-Section, Vaginal Delivery, Sensors, Heart Rate (HR), Respiratory Rate (RR), Blood Oxygen Saturation (SpO2), Skin Temperature (Tskin), Pulse Rate (PR)
Medical subject headings
Asphyxia Neonatorum, Pregnancy Complications, Infant Death, Infant, Newborn, Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Wireless skin sensors vital sign monitoring systemDevice

    Also called Anne Arc (Sibel Health Inc), Radical-7 (Masimo)

    The wireless monitoring system will be applied to the newborn and consist of a chest sensor (Anne Arc by Sibel Inc.) and a RAD-7 (Masimo)pulse oximeter limb sensor.

  • Wired vital sign monitoring systemDevice

    Also called Infinity M540 (Draeger)

    A standard ECG and SpO2 monitoring device will be applied suing the Infinity M540 monitor (Draeger, Germany). The chest sensor will be placed as per standard of care on the newborn's chest and abdomen, and the SpO2 sensor on their hands or feet.

Study groups in NCT06693817
Study groupRoleWhat they receive
Vaginal BirthOtherWireless monitoring system placed first for vaginal birth. 15-20 minutes later, the wired monitoring system is placed. Both systems stay in place for 2 hours.
Receives: Device: Wireless skin sensors vital sign monitoring system; Device: Wired vital sign monitoring system
C-Section BirthOtherSystem placement randomized for C-section. One system placed first and the alternate placed immediately after. Both systems stay in place for 2 hours.
Receives: Device: Wireless skin sensors vital sign monitoring system; Device: Wired vital sign monitoring system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Feasibility of using a wireless monitoring system immediately after delivery for HR.

    Percentage of time for which heart rate (HR) is displayed.

    Measured: 6 months

  2. Feasibility of using a wireless monitoring system immediately after delivery for RR.

    Percentage of time for which respiratory rate (RR) is displayed.

    Measured: 6 months

  3. Feasibility of using a wireless monitoring system immediately after delivery for SpO2.

    Percentage of time for which blood oxygen saturation (SpO2) is displayed.

    Measured: 6 months

  4. Feasibility of using a wireless monitoring system immediately after delivery for Tskin

    Percentage of time for which skin temperature (Tskin) is displayed.

    Measured: 6 months

  5. Feasibility of using a wireless monitoring system immediately after delivery - Gap occurence

    Occurrence of gaps in signal detection/recordings (% and length in seconds).

    Measured: 6 months

  6. Feasibility of using a wireless monitoring system immediately after delivery - Gap causes

    Causes of the gaps in signal detection/recordings.

    Measured: 6 months

  7. Feasibility of using a wireless monitoring system immediately after delivery - User satisfaction

    Descriptive analysis of user surveys and their satisfaction with the wireless system.

    Measured: 6 months

  8. Safety of using a wireless system immediately after delivery - skin score

    Skin score (Neonatal Skin Condition Score) to be determined by a blinded dermatologist using de-identified pictures of the skin after removal of the sensors of each system. A "perfect" score using the NSCS is 3; the worst score is 9.

    Measured: 6 months

  9. Safety of using a wireless system immediately after delivery - pain scale

    Pain scale (Neonatal Infant Pain Scale) to assess any discomfort or pain during the removal of the sensors, with higher scores indicating greater pain.

    Measured: 6 months

  10. Safety of using a wireless system immediately after delivery - clinical event discrepancies

    Clinically significant events detected by the wired system (HR < 100 bpm or SpO2 < 80%) but missed by the wireless system.

    Measured: 6 months

  11. Assess the accuracy of this wireless system - correlation coefficient.

    Measuring HR, RR, SpO2 and Tskin signals compared with the "standard of care" wired system - Correlation coefficient

    Measured: 6 months

  12. Assess the accuracy of this wireless system - slope

    Measuring HR, RR, SpO2 and Tskin signals compared with the "standard of care" wired system - Slop

    Measured: 6 months

  13. Assess the accuracy of this wireless system - variance accounted for

    Measuring HR, RR, SpO2 and Tskin signals compared with the "standard of care" wired system - Variance accounted for

    Measured: 6 months

  14. Assess the accuracy of this wireless system - bias.

    Measuring HR, RR, SpO2 and Tskin signals compared with the "standard of care" wired system - Bias

    Measured: 6 months

Secondary outcomes (1)
  1. Time between sensors placement and data display (seconds)

    To determine the time (seconds)between sensors placement and data display for each system (seconds)

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Nov 2024
  2. Study start8 Apr 2025
  3. Primary completion30 Jul 2027 (estimated)
  4. Study completion30 Dec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
600 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06693817
Sponsor's protocol ID
AWARD Study
Acronym
AWARD
Status last verified
May 2026
First submitted
30 Oct 2024
Last updated
8 May 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in