Liver Transplant, ComplicationsBRILLIANTNCT06716541

Biodegradable Stents in Liver Transplant RecipIents for Treatment of Biliary Anastomotic Strictures

A study testing ERCP implantation of a biodegradable stent and ERCP implantation of plastic stents in people with Liver Transplant, Complications and Biliary Anastomotic Stenosis, run by Institute for Clinical and Experimental Medicine at 1 site in Czechia.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

Biliary complications after liver transplantation (LT) remain common and are associated with higher morbidity in liver transplant recipients and liver graft failure. Anastomotic biliary strictures are the most common biliary strictures after LT. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
ERCP implantation of a biodegradable stent and ERCP implantation of plastic stents
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
70 participants
Where
1 siteCzechia
Study dates
1 Nov 2024to 31 Dec 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥18 years
  • Liver transplant recipients
  • Duct-to-duct biliary anastomosis
  • Anastomotic biliary stricture (cholestasis unexplained by other causes and/or liver biopsy showing altered biliary drainage and/or anastomotic stricture on MRCP)
  • Signed informed consent

Who cannot join

  • Hepaticojejunoanastomosis
  • Physical and/or psychological inability to understand the aims of the research and to adequately cooperate
  • Pregnancy

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Tomas Hucl, Prof contact

420261364016

tomas.hucl@ikem.cz

Czechia1 site, 1 recruiting
  • Institute for Clinical and Experimental Medicine, Department of Gastroenterology and Hepatology

    Prague, 140 21

    Tomas Hucl, Prof, 00420261364016, tomas.hucl@ikem.cz

    Iveta Matulova, 00420261365154, iveta.matulova@ikem.cz

    Recruiting

Other trials in Czechia

About this study

Official title: Biodegradable Stents Versus Plastic Stents for Treatment of Biliary Anastomotic Strictures in Liver Transplant RecipIents

Biliary complications after liver transplantation (LT) remain common and are associated with higher morbidity in liver transplant recipients and liver graft failure. Anastomotic biliary strictures are the most common biliary strictures after LT. Today, the gold standard for treatment remains endoscopic retrograde cholangiopancreatography (ERCP) with either multiple plastic stenting (MPS) or fully covered metal stents. These methods have disadvantages such as the need for repeated ERCP procedures, high costs or the risk of migration.

Biodegradable stents (BDS) are a novel type of stents made from various synthetic polymers or their copolymers, which are now being used in a variety of medical fields, including the pancreatobiliary tract.The use of biodegradable stents has shown good potential in the treatment of benign biliary strictures. However, overall data on their endoscopic use in liver transplant recipients, particularly in the treatment of anastomotic biliary strictures, are scarce. Most studies have either been in animal models, using percutaneously implanted stents, or in non-transplanted patients. There are no randomised controlled trials investigating their use in LT patients. Based on the available evidence, the use of BDS in the treatment of anastomotic biliary strictures in liver transplant recipients appears to be a promising technique that may be as effective as the standard treatment with MPS, but may reduce the number of ERCP procedures and eliminate the risk of migration.

The aim of this randomised prospective study is to compare the difference in rates of anastomotic stricture resolution between the active (BDS) and control (MPS) groups to demonstrate non-inferiority of the biodegradable stents. Outcomes will be classified as complete resolution (no significant stricture at the anastomotic site on imaging and resolution of cholestasis), significant response (relative stricture and resolution of cholestasis) or failure (persistent stricture and/or persistent cholestasis). Secondary outcomes are technical feasibility, immediate and late complications.

Read the detailed description

Liver transplantation (LT) is nowadays a standard treatment method of end-stage liver disease, primary liver cancer and acute liver failure.

Biliary complications (BCs) following liver transplantation are the leading source of morbidity and liver graft failure and are associated with up to 10% mortality rate. The incidence of BCs remains high, being reported in 10-25% in cadaveric donors (DDLT) and in more than 30% in living donor liver transplantations (LDLT), despite improved both preoperative and postoperative care and enhanced surgical technique. Anastomotic biliary strictures (ABS) are together with bile leaks the most common biliary complication occurring any time after LT, but being primarily found within the first year LT. The incidence ranges between 5-15% in DDLT and 13-36% in LDLT. Anastomotic strictures are typically present at the site of anastomosis, tend to be short, single and constitute up to 86% of all biliary strictures. The clinical presentation can differ from patients being asymptomatic to some presenting with symptoms of biliary obstruction (jaundice, fever, chills, nausea, abdominal pain). The clinical picture can resemble also other conditions and it is important to differentiate biliary complication (BC) from other similarly presenting entities such as acute rejection, hepatic artery thrombosis, recurrence of primary sclerosing cholangitis or acute hepatitis). The gold standard for diagnosis of BCs is MRCP with reported sensitivity and specificity of up to 95%.

The first line therapy of BCs is endoscopic retrograde cholangiopancreatography (ERCP), in case of failure or altered anatomy percutaneous approach may be indicated. If both methods fail surgery is required. ERCP is an invasive endoscopic technique used primarily for therapy of pancreatobiliary tract. It is associated with risk of complications such as acute pancreatitis, bleeding, acute cholangitis or in rare cases perforation.

There are two standard approaches in the treatment of anastomotic biliary strictures, similarly to the treatment of other benign strictures of the bile duct. First, the use of multiple plastic stents (MPS) requiring their repeated endoscopic exchanges may be employed. Alternatively, a single self-expandable metal stent is placed for a longer period of time.

The endoscopic therapy of anastomotic strictures using multiple plastic stents typically requires multiple stent exchanges, starting with placing a single stent and adding multiple stents during further sessions. The sessions are scheduled every 1 to 3 months. The resolution of the anastomotic stricture is usually achieved in 12months, exposing the patient typically to 3-4 ERCP procedures. MPS technique was firstly described and put in practice in a single center study by Costamagna et al. with clinical success rate in 89%. After that many other studies have been published regarding this topic, including a meta-analysis, where the resolution rate of strictures were reported in 94%-100%. Finally in 2017 by Koksa et al. was reported a review demonstrating that in patients with more than 12 months of stenting, with higher total number of stents and number of stents inserted per session, a higher resolution rate and a lower recurrence rate were showed. Alternative option for the endoscopic treatment of ABS is the use of a single fully covered self-expandable metal stent (FC-SEMS), in studies showing similar rates of ABS resolution compared to MPS method with the advantage of not repeating ERCP to place multiple stents, although with higher risk of migration.

The use of endoscopically inserted biodegradable stents is a novel technique with a potential to overcome some downsides of standard treatment with MPS and FC-SEMS. Biodegradable stents are made of different synthetic polymers or their co-polymers. First use of biodegradable stents in the GI tract was described in the setting of an esophageal stricture in 1996 and was later used in small intestine and colon for benign strictures. In the pancreatobiliary tract biodegradable stents have begun to be used in the recent years, mostly for benign biliary strictures such as those caused by chronic pancreatitis and in postoperative cystic duct leaks. Most of the reported experience comes from percutaneously inserted stents. The experience with endoscopic insertion of biodegradable stents is very limited and the data about use of biodegradable stents in liver transplant recipients are extremely scarce.

A systematic review on the use of biodegradable stents in biliary tract by Siiki at al. reviewed studies from 1997 to 2017. This review included 12 animal and 7 human studies. In human studies biodegradable stents were inserted in 4 studies percutaneously and in 3 studies endoscopically. The main indications were benign biliary strictures, postoperative cystic duct leaks, leaks from hepaticojejunal anastomosis, strictures of hepaticojejunal anastomosis, bilioenteric anastomosis strictures or chronic pancreatitis. In all studies stents made out of polydioxanone with time of degradation between 3-6 months were used. The studies proved good feasibility and safety of BDS in both animal and human setting and demonstrated their successful use in the treatment of benign biliary strictures and cystic bile duct leaks. In the first and biggest study with the endoscopic use of biodegradable stents in humans in treatment of cystic duct leaks and benign biliary strictures (BBS), the overall clinical success rate in treatment of BBS was noted in 83% with no secondary hyperplastic strictures. Surprisingly quite high rate of acute cholangitis occurred, in 23% after 90 days, although all cases were mild.

In another recent systematic review and metanalysis by Almeida et al. biodegradable stents were compared to multiples plastic stent implantation in benign biliary strictures. In total 9 studies met the inclusion criteria and were analyzed. Biodegradable stent group (BDBS) consisted of one retrospective and two prospective cohort studies, where stents were deployed both endoscopically and percutaneously with a minimal follow up of 20,8 months. In contrast the MPS group consisted of one randomized control trial comparing the use of multiple plastic stents to FCSEMS for different types of benign biliary strictures, and 5 cohort studies from which were 4 retrospective and one was prospective with a minimal follow up of 78,4 months. The overall success rate to achieve long-term stricture resolution was 83% for the BDBS group and 84% for the MPS group. The average number of interventions in the MPS group was 3 in contrast to 1 in the BDBS group (per case). In a majority of cases the stents were placed percutaneously and only one cohort study included endoscopically released BDBS (13 patients). The treatment-related complication rate was reported for acute cholangitis, acute pancreatitis, stent migration and abdominal pain and was 24,1%, 0,7 %, 1,5 %, 0, 8% for BDBS and 6,1%, 2,7%, 6,8% and 6,8 % for MPS.

An observational single center study by Dopazo et al. reported 20 adult and pediatric patients where BDS were used for benign biliary strictures after liver transplantation using a transhepatic approach. The overall feasibility was 100%, the overall clinical success including both anastomotic and nonastomotic strictures was 75%. The clinical success was higher in anastomotic strictures (81,25%). Only one case of acute pancreatitis was observed.

Based on the available evidence, BDS have shown promising results with good stent patency, feasibility, efficacy and safety profile. Therefore, BDS may represent a novel treatment modality and an alternative to current techniques in the management of biliary anastomotic strictures with a reduced number of ERCPs. However, prospective comparative data are needed.

The investigators aim to compare the use of biodegradable stents with the multiple stenting technique using plastic stents for the treatment of biliary anastomotic strictures and to demonstrate the non-inferiority of biodegradable stents, as well as the safety profile and technical feasibility.

Being tested
ERCP implantation of a biodegradable stent, ERCP implantation of plastic stents

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ERCP implantation of a biodegradable stentProcedure or surgery

    Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a biodegradable stent to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).

  • ERCP implantation of plastic stentsProcedure or surgery

    Endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent or multiple stents to treat anastomotic biliary stricture (possibly combined with removal of previous plastic stents).

Study groups in NCT06716541
Study groupRoleWhat they receive
Management of anastomotic biliary strictures with biodegradable stentsExperimentalInitially, a single biodegradable stent is used for treatment of an anastomotic biliary stricture. If needed, this may be followed by usage of another biodegradable stent or plastic stents.
Receives: Procedure: ERCP implantation of a biodegradable stent; Procedure: ERCP implantation of plastic stents
Management of anastomotic biliary strictures with multiple plastic stents inActive comparatorMultiple plastic stents are used for treatment of an anastomotic biliary stricture.
Receives: Procedure: ERCP implantation of plastic stents

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Persisting anastomotic stricture resolution

    Rate of resolution of the anastomotic stricture as confirmed by Endoscopic retrograde cholangiopancreatography (ERCP) or Magnetic Resonance Cholangiopancreatography (MRCP) examination within 12 months since the initial procedure and persistence of the resolution (confirmed by MRCP) 6 months after the initial resolution.

    Resolution of anastomotic stricture is defined as all of the following simultaneously:

    • no need of further restenting
    • residual narrowing of lumen less than 20%)
    • alkaline phosphatase (ALP) below two times the upper limit of normal (unless a cause of the increase other than the anastomotic stricture is identified)

    Measured: 12+6 months

  2. Number of ERCPs

    The total number of ERCPs required for the stricture resolution

    Measured: 12 months

Secondary outcomes (8)
  1. Initial anastomotic stricture resolution

    Rate of resolution of the anastomotic stricture as confirmed by Endoscopic retrograde cholangiopancreatography (ERCP) or Magnetic Resonance Cholangiopancreatography (MRCP) examination within 12 months since the initial procedure.

    Resolution of anastomotic stricture is defined as all of the following simultaneously:

    • no need of further restenting
    • residual narrowing of lumen less than 20%)
    • alkaline phosphatase (ALP) below two times the upper limit of normal (unless a cause of the increase other than the anastomotic stricture is identified)

    Measured: 12 months

  2. Technical feasibility

    Specific technical features related to the biodegradable stent (loadability, pushability, stent deployment, fluoroscopic visibility) and overall technical performance compared to commonly used plastic stents will be evaluated by endoscopists using a questionnaire at the end of the treatment period.

    Measured: 12 months

  3. Safety

    Device or procedure related adverse events (bleeding, perforation, cholangitis, pancreatitis, stent migration)

    Measured: 12 months

  4. Number of stents placed

    The total number of stents placed during ERCPs

    Measured: 12 months

  5. Duration of stenting

    The duration of the stenting period measured in months from the first to the last ERCP procedure.

    Measured: 12 months

  6. Degradation of biodegradable stents

    Absence of signal void in common bile duct at MRCP at 6 months in biodegradable stents group

    Measured: 6 months

  7. Quality of life

    Validated questionnaire investigating quality of live post intervention/s

    Measured: 12 months

  8. Cost

    Costs associated with the performed procedures.

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Dec 2024
  2. Study start1 Nov 2024
  3. Primary completion31 Dec 2027 (estimated)
  4. Study completion31 Dec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
70 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06716541
Sponsor's protocol ID
IKEM BDS
Acronym
BRILLIANT
Status last verified
Nov 2024
First submitted
25 Nov 2024
Last updated
4 Dec 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing ERCP implantation of a biodegradable stent and ERCP implantation of plastic stents in people with Liver Transplant, Complications and Biliary Anastomotic Stenosis, run by Institute for Clinical and Experimental Medicine at 1 site in Czechia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 4 Dec 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Czechia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Tomas Hucl, Prof (420261364016, tomas.hucl@ikem.cz), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Persisting anastomotic stricture resolution (time frame: 12+6 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Dec 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in