Frequency and Type of Medical Adhesive-Related Skin InjuryNCT06717308
Evaluation of a Switchable Acrylic Adhesive Drape for Safer Removal in Negative Pressure Wound Therapy Applications.
A study testing Comfort Release® NPWT drape in people with Frequency and Type of Medical Adhesive-Related Skin Injury and NPWT Drape Seal Effectiveness Rate (or Leak Incidence Rate), run by Global Biomedical Technologies, LLC at 7 sites in United States.
Trial summary
Negative pressure wound therapy (NPWT) is widely used for chronic and acute wounds, severe burns, and post-operative care. Despite its benefits, the strong adhesive required to maintain an airtight seal increases the risk of medical adhesive-related skin injuries (MARSI), pain, and discomfort during removal. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Frequency and Type of Medical Adhesive-Related Skin Injury, NPWT Drape Seal Effectiveness Rate (or Leak Incidence Rate), Clinician Acceptability of New NPWT Drape
- What is being tested?
- Comfort Release® NPWT drape
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 300 participants
- Where
- 7 sitesUnited States
- Study dates
- 10 Feb 2025to 31 Mar 2027
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- 18 years or older post-surgical inpatients with a plan of treatment using NPWT
- Able to communicate and consent to participation in the study
- Access to V.A.C. by KCI drape and NPWT kits
- Able to report pain level using a pain scale.
- If outpatient- able to return to the clinic for all drape/dressing changes
Who cannot join
- History of known hypersensitivity to acrylic adhesives
- History of known hypersensitivity to isopropyl alcohol
- The patient is expected to be unconscious during the drape removal/change
- -NOTE: For the Weill Cornell Medicine site only: Patient is expected to be unconscious during ALL drape removal/changes.
- Under the age of 18 years 5. Unable to give consent, including a language barrier, unless an interpreter is readily available.
Trial locations and contacts
7 sites in 1 country. Contact the study team or a site near you to ask about taking part.
Denise L Anderson, Director of Clinical Operations & Communications, RN, WCC contact
7 sites in 1 country
United States7 sites, 4 recruiting
- Not yet recruiting
Cutting Edge Research LLC
Circleville, Ohio, 43113
Marie Liden, 740-474-3850, billing@wafl-ohio.com
Brock A Liden, DPM
- Recruiting
Eazy Foot & Ankle
Los Angeles, California, 90035
Rosie Berrios, Office Manager, 310-326-0202, allsouthbayfootcare@gmail.com
Jazmine, Receptionist, 424-279-9332, info@eazyfoot.com
- Active, not recruiting
Absolute Medical Center, LLC
Miami, Florida, 33126
- Completed
Columbia University Medical Center
New York, New York, 10032
- Recruiting
Weill Cornell Medical Center
New York, New York, 10065
Amy Chun, chh4020@med.cornell.edu
Robert J Winchell, MD
- Terminated
Vital Medical Research
Sweetwater, Florida, 33174
- Recruiting
All South Bay Footcare/Podiatry Group, Inc.
Torrance, California, 90505
Rosie Berrios, Office Manager, 310-326-0202, allsouthbayfootcare@gmail.com
Jazmine, Receptionist, 424-279-9332, info@eazyfoot.com
About this study
Official title: Surgical Drape With an Atraumatic Acrylic Adhesive for Negative Pressure Wound Therapy
Negative pressure wound therapy (NPWT) is widely used for chronic and acute wounds, severe burns, and post-operative care. Despite its benefits, the strong adhesive required to maintain an airtight seal increases the risk of medical adhesive-related skin injuries (MARSI), pain, and discomfort during removal. Global Biomedical Technologies (GBT) aims to develop an NPWT drape with "switchable adhesive" technology to enhance removal while maintaining an effective seal. This innovation is expected to benefit both single-use and serial-use NPWT applications by reducing MARSI and improving patient comfort.
This project will compare the functionality and acceptability of Comfort Release® NPWT drapes with the industry-standard V.A.C. drape (KCI Technologies, Inc.), or other facility standard drape, in a non-blinded randomized controlled trial.
Read more
Specific Aims Aim 1: Compare Comfort Release® drapes with V.A.C. drapes in single or short-term use NPWT applications in post-surgical patients (n=200) at Columbia University Medical Center, Weill Cornell Medical Center, and Absolute Medical Center.
Milestones: Demonstrate statistically significant (α=0.05) improvement over V.A.C. drapes in:
Reduction of MARSI (Medical Adhesive-Related Skin Injury scoring system) Decreased pain (Indiana Polyclinic Combined Pain Scale) Reduced need for pain/anxiety medication Equivalent or improved seal effectiveness (leak incidence rate) Clinician acceptability Reduced nursing time by ≥20% Economic value through time and cost savings Aim 2: Compare Comfort Release® drapes with V.A.C. drapes in serial-use NPWT applications in chronic wound patients (n=100) at Weill Cornell Medical Center, Vital Medical Research, and All South Bay Footcare. Patients will undergo approximately three NPWT drape changes per week.
Milestones: Demonstrate statistically significant (α=0.05) improvement over V.A.C./or standard drapes in:
Reduction of MARSI Decreased pain (Indiana Polyclinic Combined Pain Scale) Improved compliance with treatment duration Reduced need for pain/anxiety medication Equivalent or better seal effectiveness Clinician acceptability (questionnaire score >4) Reduced nursing time by ≥20% Economic value through time and cost savings
At each dressing change and at final removal, qualitative data from clinicians will be collected to assess the acceptability and usability of Comfort Release® NPWT drapes.
Read the detailed description
Study Overview: Two-Aimed NPWT Drape Clinical Trial
Global Biomedical Technologies is advancing a novel surgical drape for negative pressure wound therapy (NPWT) that leverages Comfort Release®-a "switchable adhesive" technology designed for painless and trauma-free removal. This innovative adhesive incorporates oligo(glycerol sebacate) (OGS) and polyacrylate, allowing strong bonding during use and rapid release upon exposure to isopropyl alcohol (IPA). This product addresses the unmet need for effective NPWT adhesives that prevent medical adhesive-related skin injuries (MARSI) without compromising performance.
Key Features of Comfort Release® Adhesive:
- Composition: OGS, a biodegradable elastomer pre-polymer, forms hydrogen bonds with IPA, enabling adhesive release.
- Performance: A >70% drop in adhesive strength within 5 seconds of 70% IPA application.
- Benefits: Reduces pain and trauma at removal, maintains effective NPWT seals, and improves patient outcomes.
This Direct-to-Phase II study compares the Comfort Release® NPWT drape with the market leader, V.A.C. drape (KCI Technologies, Inc.), or standard drape, focusing on clinical performance, patient outcomes, and clinician feedback.
Study Objectives:
- Evaluate Performance: Assess the skin irritation, pain, seal effectiveness, and clinician usability of the Comfort Release® drape.
- Provide Clinical Validation: Gather data for FDA 510(k) clearance, supporting the introduction of a novel NPWT adhesive drape to the market. Purpose: NPWT is commonly used for the management of more than 100 indications, including chronic wounds, acute open wounds, burns, and postoperative sites. An estimated 6.5 million patients suffer from chronic wounds, and an estimated 48 million inpatient surgeries are performed each year in the US3,4. NPWT involves covering a wound with an airtight dressing sealed by adhesive and applying sub-atmospheric pressure via a vacuum device. Strong adhesives are typically required for NPWT drapes. Exudate can leak with weaker adhesives, tainting peri-wound skin, reducing drape adherence, and potentially leading to macerated tissue, increased wound size, and slower or reduced healing. However, strong adhesives substantially increase the risk for medical adhesive-associated skin injuries (MARSI) during drape removal/changes. Drape removal can cause epidermal layers to separate and/or detach from the dermis, resulting in skin tears and moisture-associated skin damage, and skin irritation. Studies show the type of drape used correlates with acute pain during dressing changes and injury to the peri-wound tissue, in turn delaying the wound healing process. Previous attempts to develop a product with strong adhesion and easy removability have fallen short. Silicone adhesives have poor skin adherence and are expensive, thus requiring stronger adhering acrylic sealing strips or other acrylic components to mitigate leaks. Addressing this unmet need, Global Biomedical Technologies has developed an adhesive acrylic NPWT drape incorporating innovative ester oligomers that release from the skin with the addition of isopropyl alcohol. This painless adhesive technology, "Comfort Release®," has proven high patient satisfaction with a low incidence of MARSI. This project will confirm the superior functionality and acceptability of Comport Release® NPWT drapes against the market leader (V.A.C. drape by KCI Technologies, Inc.), or standard drape, in both single-use and serial-use NPWT applications. The data obtained from this Direct to Phase II project is expected to support a 510K FDA clearance. The proposed research aims to provide the clinical validation and data needed for a 510 (k) FDA clearance. If successful, the knowledge gained as a result of this trial can bring to market a novel surgical drape for wound therapy that has strong potential to be pain-free and atraumatic and will help facilitate wound healing. This can potentially contribute to improved patient outcomes. Given that there are minimal risks in this trial, we find it reasonable to obtain the knowledge and clinical data needed to bring this drape to pursue FDA clearance and bring this novel NPWT drape to market. Addressing this, Global Biomedical Technologies will compare Comfort Release® NPWT drape with an innovative "switchable adhesive" technology for painless and trauma-free removal with the standard KCI V.A.C.® drape in post-surgical wound patients. The types of post-op wounds that receive NPWT that are eligible for this study include adult acute wounds and incisions, as well as chronic wounds and burns. ________________________________________ Study Design: Single-Center, Two-Armed, Randomized Trial
- Aim 1: Short-duration use (200 patients):
- Assess single-use (in most cases) application, skin irritation, pain at removal, and seal effectiveness.
- Study duration: Approximately 2 years.
- Population: General post-surgical patients.
- Aim 2: Serial-use application (100 patients):
- Assess cumulative effects, including MARSI incidence, narcotic usage, compliance, and leak rates.
- Study duration: Approximately 2 years.
- Population: Chronic wound patients undergoing serial NPWT. Assessments:
- Skin Irritation and Injury:
- Tool: MARSI scoring system (erythema, tension blisters, maceration, etc.).
- Immediate and 30-minute post-removal assessments.
- Pain Evaluation:
- Scale: Indiana Polyclinic Combined Pain Scale (0-10).
- Seal Effectiveness:
- Leak incidence recorded by clinicians.
- Treatment Compliance:
- Monitoring adherence to prescribed NPWT regimens.
- Medication Use:
- Tracking pain and stress-reducing medication usage.
- Clinician Acceptability:
- Documented via case report forms. Risk Mitigation and Ethical Considerations:
- Minimal Risks:
- Potential for skin irritation or discomfort, inherent to NPWT.
- Breach of confidentiality mitigated through deidentification and secure data storage.
- Informed Consent:
- Lay-language consent forms provided, ensuring participants fully understand study procedures, risks, and benefits.
- Oversight by Denise Anderson, RN, WCC, with site coordinators.
- Adverse Event Reporting:
- Immediate reporting of new risks or adverse events to the Columbia IRB. Statistical and Sample Size Justification:
- Aim 1: 200 patients across two sites (CUIMC, AMC). o Effect size: Moderate (d=0.4); significance at α=0.05 with 80% power.
- Aim 2: 25/25/50 patients/group (100 total) at three sites (WCM, VMR, and ASBF). o Effect size: Moderate (d=0.6), targeting higher MARSI incidence in chronic cases. Sponsor \& Principal-Investigator Howard S. Rosing, MD, PhD CEO, Global Biomedical Technologies, LLC 1211 Acorn Knob Greensboro, GA 30642 Contact: hrosing@comfortrelease.com Phone: (m) 239-330-5646 Principal Investigator: Robert John Winchell, MD Chief, Division of Trauma \& Burns Weill Cornell Medical Center (WCM) 525 East 68th Street, Room P7-714, Box 116 New York, NY 10065 Contact: row9057@med.cornell.edu Phone: 646-962-8490 Co-Principal Investigator: Jarrod Terrence Bogue, MD Clinical Instructor in Surgery, Columbia University Irving Medical Center (CUIMC) 161 Fort Washington Avenue, Suite 5 New York, NY 10032 Contact: jb3892@cumc.columbia.edu Phone: 203-668-8595 Co-Principal Investigator: Daniel Careaga, MD- Careaga Plastic Surgery 220 Alhambra Circle, First Floor Coral Gables, FL 33134 Absolute Medical Center (AMC) 5040 Northwest 7th Street Suite 500 Miami, Florida 33126 Contact: Juan Diaz drdiaz@absolutemedicalcenter.com> 305-508-0004 Co-Principal Investigator: Deeza Frankel, DPM Vital Medical Research (VMR) 10780 W Flagler ST, Suite #6 Sweetwater, FL 33174 Contact: Alejandro Morlan, APRN Alejandro.m@vitalmedicalresearch.com 305-703-4414 Co-Principal Investigator: Albert Avi Elhiani, DPM All South Bay Footcare/Podiatry Group, Inc. 23365 Hawthorne Blvd., Suite 101 Torrance, CA 90505 Phone: (310) 326-0202 Second location: Eazy Foot \& Ankle 9233 W. Pico Blvd, #201 Los Angeles, CA 90035 (424) 279-9332 Contact: Rosie Berrios allsouthbayfootcare@gmail.com 310-326-0202 IRB Compliance: Advarra IRB serves as the single IRB for all participating sites. Advarra IRB is fully accredited by the Association for the Accreditation of Human Research Protection Programs (AAHRPP).
- Conditions
- Frequency and Type of Medical Adhesive-Related Skin Injury, NPWT Drape Seal Effectiveness Rate (or Leak Incidence Rate), Clinician Acceptability of New NPWT Drape, Patient Drop-out Rate From Prescribed NPWT Treatment, Pain Assessment During Medical Adhesive Drape Removal
- Being tested
- Comfort Release® NPWT drape
- Keywords
- Medical Adhesive-Related Skin Injury (MARSI), pain with adhesive medical products, wound care, NPWT drape, Negative Pressure Wound Therapy, Surgical Drapes
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Comfort Release® NPWT drapeDevice
Comfort Release® NPWT drape- painless and trauma-free removal, as compared to the control NPWT drape.
| Study group | Role | What they receive |
|---|---|---|
| Single or short-term use post-surgical NPWT drape application | Active comparator | Aim 1 description: A comparison of the performance of Comfort Release® drapes with V.A.C. drapes in single-use NPWT applications in a randomized controlled trial. Post-surgical patients (n=200) with a prescribed treatment of Negative Pressure Wound Therapy (NPWT) will be enrolled at Columbia Presbyterian Hospital under co-Principal Investigator Dr. Jarrod Bogue and Absolute Medical Center under PI: Daniel Careage, MD, for single-use NPWT. Patients will be randomized to a single-use control (V.A.C. drape) or intervention (Comfort Release® drape). All other components of the NPWT device, including but not limited to the pump, tubing, foam, or dressing insert, will be identical. Randomize participants: 1/2 of the patients will receive the KCI drape, and 1/2 will receive the intervention - Comfort Release drape. Receives: Device: Comfort Release® NPWT drape |
| Multi-use chronic wound NPWT drape application | Active comparator | Aim 2: A comparison of the performance of Comfort Release® drapes with V.A.C. drapes in serial-use NPWT applications in a randomized controlled trial. Chronic wound patients (n=100) with prescribed NPWT will be enrolled at Weill Cornell Medical Center under Principal Investigator Dr. Robert Winchell, Vital Medical Research under Deeza Frankel, DPM, and All South Bay Footcare under Albert A. Elhiani, DPM, and Cutting Edge Research under Brock Liden, DPM. All patients will undergo 3 NPWT drape changes per week. Patients will be randomized to control (V.A.C. or standard drape) or intervention (Comfort Release® drape) for the duration of their study enrollment. All other components of the NPWT device, including but not limited to the pump, tubing, foam, or dressing insert, will be identical.
Randomize participants: 1/2 of the patients will receive KCI or standard drape, and 1/2 will receive the intervention- Comfort Release drape. Receives: Device: Comfort Release® NPWT drape |
What is being measured
The primary outcome is the main question the study is designed to answer.
Incidence of Medical Adhesive-Related Skin Injury (MARSI).
Measure: The percentage of patients experiencing Medical Adhesive-Related Skin Injury from surgical drape removal as assessed using the MARSI scale upon drape removal, and, if any abnormality is noted, a second MARSI assessment is completed. If there is a MARSI score of 1 or 2 = follow up assessment in completed in approximately 15 minutes, and a score of 3 or 4 = follow up assessment is completed in approximately 30 minutes.
Measured: From the first drape removal to the end of treatment- 1 to 8 weeks.
Patient-reported pain scores during drape removal.
Pain intensity scored on the Indiana Polyclinic Combined Pain Scale during the drape removal. Scale of 0 to10, 0 = no pain and 10= worst imaginable pain.
Measured: From enrollment to the end of treatment - from 1 - 8 weeks.
Change in medication use for anxiety, pain, and stress.
Measure: Quantity (e.g., dosage or frequency) of medications used for anxiety, pain, and stress related to drape removal.
Measured: From enrollment to the end of treatment - from 1 - 8 weeks.
Drape seal integrity (leak incidence rate).
Proportion of drapes maintaining an effective seal compared to or the control drape.
Measured: From enrollment to the end of treatment - from 1 - 8 weeks.
Patient drop-out rate from NPWT treatment due to drape issues.
Measurement: Percentage of patient who discontinue NPWT treatment before completing the prescribed treatment duration drop-out from the prescribed treatment duration to determine how much pain and skin injury plays a role in patient compliance.
Measured: From enrollment to the end of treatment - from 1 - 8 weeks.
Secondary outcomes (1)
Clinician Acceptability of Comfort Release® drape.
Measure: Time taken by the clinician (in minutes) to remove the NPWT drape while minimizing the pain the patient suffers from the drape removal. This time-saving measurement could increase the economic value of the drape.
Measured: From application of the first drape to the end of treatment - from 1 - 8 weeks.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted5 Dec 2024
- Study start10 Feb 2025
- Primary completion28 Feb 2027 (estimated)
- Study completion31 Mar 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (13)Papers the sponsor has linked to this study.
- Other trials for Frequency and Type of Medical Adhesive-Related Skin InjuryStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- 50% of the patients will receive the KCI® or standard drape (control), and 50% of the patients will receive the Comfort Release® drape (intervention). Outcomes assessed will include the effectiveness of the seal, pain during dressing removal, skin damage upon removal, and clinician acceptability.
- Masking
- None (open label)
- Enrolment
- 300 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Global Biomedical Technologies, LLC
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- National Institute for Biomedical Imaging and Bioengineering (NIBIB), Weill Medical College of Cornell University, Columbia University, Absolute Medical Center, LLC, Vital Medical Research, LLC, All South Bay Footcare, Eazy Foot & Ankle, Cutting Edge Research, LLC
- Responsible party
- Sponsor
- Investigators
- Howard S Rosing, MD, PhD, Principal investigator, Global Biomedical Technologies, LLC
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06717308
- Sponsor's protocol ID
- R44EB036280
- Other IDs
- 1R44EB036280-01
- Status last verified
- Oct 2026
- First submitted
- 21 Nov 2024
- Last updated
- 21 Oct 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: De-identified study patient data underlying the results reported for the primary and secondary outcome measures, including raw data, comparing the intervention against the market leader control.
Publications
The Indiana Polyclinic Combined Pain Scale. 2022. at https://www.painscale.com/article/the - indiana -polyclinic- combined - pain - scale .)
McNichol L, Lund C, Rosen T, Gray M. Medical adhesives and patient safety: state of the science: consensus statements for the assessment, prevention, and treatment of adhesive-related skin injuries. J Wound Ostomy Continence Nurs. 2013 Jul-Aug;40(4):365-80; quiz E1-2. doi: 10.1097/WON.0b013e3182995516.
PubMed 23759927Negative Pressure Wound Therapy Market Size, Share & Trends Analysis Report By Product (Conventional NPWT, Single- use NPWT), By Wound Type (Diabetic Foot Ulcers, Venous Leg Ulcers), By End Use, By Region, And Segment Forecasts, 2022 - 2030. 2022. (Accessed July 18, 2022, at https://www.grandviewresearch.com/industry - analysis/negative - pressure - wound - therapy - npwt - market .
Fumarola S, Allaway R, Callaghan R, Collier M, Downie F, Geraghty J, Kiernan S, Spratt F, Bianchi J, Bethell E, Downe A, Griffin J, Hughes M, King B, LeBlanc K, Savine L, Stubbs N, Voegeli D. Overlooked and underestimated: medical adhesive-related skin injuries. J Wound Care. 2020 Mar 1;29(Sup3c):S1-S24. doi: 10.12968/jowc.2020.29.Sup3c.S1. No abstract available.
PubMed 32134695Sen CK, Gordillo GM, Roy S, Kirsner R, Lambert L, Hunt TK, Gottrup F, Gurtner GC, Longaker MT. Human skin wounds: a major and snowballing threat to public health and the economy. Wound Repair Regen. 2009 Nov-Dec;17(6):763-71. doi: 10.1111/j.1524-475X.2009.00543.x.
PubMed 19903300National Health Statistic Report, Number 102, February 28, 2017
Apelqvist J, Willy C, Fagerdahl AM, Fraccalvieri M, Malmsjo M, Piaggesi A, Probst A, Vowden P. EWMA Document: Negative Pressure Wound Therapy. J Wound Care. 2017 Mar 1;26(Sup3):S1-S154. doi: 10.12968/jowc.2017.26.Sup3.S1.
PubMed 28345371Zaver V, Marietta M, Kankanalu P. Negative Pressure Wound Therapy. 2026 Feb 21. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. Available from http://www.ncbi.nlm.nih.gov/books/NBK576388/
PubMed 35015413Robertson F, Wang Y, Rosing H. An oligomeric switch that rapidly decreases t he peel strength of a pressure-sensitive adhesive. International Journal of Adhesion and Adhesives 2014; 55:64-8
Upton D, Solowiej K, Hender C, Woodyatt KY. Stress and pain associated with dressing change in patients with chronic wounds. J Wound Care. 2012 Feb;21(2):53-4, 56,58 passim. doi: 10.12968/jowc.2012.21.2.53.
PubMed 22584524Upton D, Andrews A. Pain and trauma in negative pressure wound therapy: a review. Int Wound J. 2015 Feb;12(1):100-5. doi: 10.1111/iwj.12059. Epub 2013 Mar 12.
PubMed 23489350Vuerstaek JD, Vainas T, Wuite J, Nelemans P, Neumann MH, Veraart JC. State-of-the-art treatment of chronic leg ulcers: A randomized controlled trial comparing vacuum-assisted closure (V.A.C.) with modern wound dressings. J Vasc Surg. 2006 Nov;44(5):1029-37; discussion 1038. doi: 10.1016/j.jvs.2006.07.030. Epub 2006 Sep 26.
PubMed 17000077Wang Y, Ameer GA, Sheppard BJ, Langer R. A tough biodegradable elastomer. Nat Biotechnol. 2002 Jun;20(6):602-6. doi: 10.1038/nbt0602-602.
PubMed 12042865
Study at a glance
From the registry record, last updated by the sponsor on 21 Oct 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Surgical Drape With an Atraumatic Acrylic Adhesive for Negative Pressure Wound Therapy
- ClinicalTrials.gov ID
- NCT06717308
- Acronym / sponsor ID
- R44EB036280
- Conditions
- Frequency and Type of Medical Adhesive-Related Skin Injury, NPWT Drape Seal Effectiveness Rate (or Leak Incidence Rate), Clinician Acceptability of New NPWT Drape, Patient Drop-out Rate From Prescribed NPWT Treatment, Pain Assessment During Medical Adhesive Drape Removal
- Keywords
- Medical Adhesive-Related Skin Injury (MARSI), pain with adhesive medical products, wound care, NPWT drape, Negative Pressure Wound Therapy, Surgical Drapes
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 300 participants (estimated)
- Lead sponsor
- Global Biomedical Technologies, LLCIndustry (pharma, biotech, devices)
- Collaborators
- National Institute for Biomedical Imaging and Bioengineering (NIBIB), Weill Medical College of Cornell University, Columbia University, Absolute Medical Center, LLC, Vital Medical Research, LLC, All South Bay Footcare, Eazy Foot & Ankle, Cutting Edge Research, LLC
- Study start
- 10 Feb 2025 (actual)
- Primary completion
- 28 Feb 2027 (estimated)
- Study completion
- 31 Mar 2027 (estimated)
- First posted
- 5 Dec 2024 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Negative pressure wound therapy (NPWT) is widely used for chronic and acute wounds, severe burns, and post-operative care. Despite its benefits, the strong adhesive required to maintain an airtight seal increases the risk of medical adhesive-related skin injuries (MARSI), pain, and discomfort during removal. Global Biomedical Technologies (GBT) aims to develop an NPWT drape with "switchable adhesive" technology to enhance removal while maintaining an effective seal. This innovation is expected to benefit both single-use and serial-use NPWT applications by reducing MARSI and improving patient comfort.
This project will compare the functionality and acceptability of Comfort Release® NPWT drapes with the industry-standard V.A.C. drape (KCI Technologies, Inc.), or other facility standard drape, in a non-blinded randomized controlled trial.
Specific Aims Aim 1: Compare Comfort Release® drapes with V.A.C. drapes in single or short-term use NPWT applications in post-surgical patients (n=200) at Columbia University Medical Center, Weill Cornell Medical Center, and Absolute Medical Center.
Milestones: Demonstrate statistically significant (α=0.05) improvement over V.A.C. drapes in:
Reduction of MARSI (Medical Adhesive-Related Skin Injury scoring system) Decreased pain (Indiana Polyclinic Combined Pain Scale) Reduced need for pain/anxiety medication Equivalent or improved seal effectiveness (leak incidence rate) Clinician acceptability Reduced nursing time by ≥20% Economic value through time and cost savings Aim 2: Compare Comfort Release® drapes with V.A.C. drapes in serial-use NPWT applications in chronic wound patients (n=100) at Weill Cornell Medical Center, Vital Medical Research, and All South Bay Footcare. Patients will undergo approximately three NPWT drape changes per week.
Milestones: Demonstrate statistically significant (α=0.05) improvement over V.A.C./or standard drapes in:
Reduction of MARSI Decreased pain (Indiana Polyclinic Combined Pain Scale) Improved compliance with treatment duration Reduced need for pain/anxiety medication Equivalent or better seal effectiveness Clinician acceptability (questionnaire score >4) Reduced nursing time by ≥20% Economic value through time and cost savings
At each dressing change and at final removal, qualitative data from clinicians will be collected to assess the acceptability and usability of Comfort Release® NPWT drapes.
Detailed description
Study Overview: Two-Aimed NPWT Drape Clinical Trial
Global Biomedical Technologies is advancing a novel surgical drape for negative pressure wound therapy (NPWT) that leverages Comfort Release®-a "switchable adhesive" technology designed for painless and trauma-free removal. This innovative adhesive incorporates oligo(glycerol sebacate) (OGS) and polyacrylate, allowing strong bonding during use and rapid release upon exposure to isopropyl alcohol (IPA). This product addresses the unmet need for effective NPWT adhesives that prevent medical adhesive-related skin injuries (MARSI) without compromising performance.
Key Features of Comfort Release® Adhesive:
- Composition: OGS, a biodegradable elastomer pre-polymer, forms hydrogen bonds with IPA, enabling adhesive release.
- Performance: A >70% drop in adhesive strength within 5 seconds of 70% IPA application.
- Benefits: Reduces pain and trauma at removal, maintains effective NPWT seals, and improves patient outcomes.
This Direct-to-Phase II study compares the Comfort Release® NPWT drape with the market leader, V.A.C. drape (KCI Technologies, Inc.), or standard drape, focusing on clinical performance, patient outcomes, and clinician feedback.
Study Objectives:
- Evaluate Performance: Assess the skin irritation, pain, seal effectiveness, and clinician usability of the Comfort Release® drape.
- Provide Clinical Validation: Gather data for FDA 510(k) clearance, supporting the introduction of a novel NPWT adhesive drape to the market. Purpose: NPWT is commonly used for the management of more than 100 indications, including chronic wounds, acute open wounds, burns, and postoperative sites. An estimated 6.5 million patients suffer from chronic wounds, and an estimated 48 million inpatient surgeries are performed each year in the US3,4. NPWT involves covering a wound with an airtight dressing sealed by adhesive and applying sub-atmospheric pressure via a vacuum device. Strong adhesives are typically required for NPWT drapes. Exudate can leak with weaker adhesives, tainting peri-wound skin, reducing drape adherence, and potentially leading to macerated tissue, increased wound size, and slower or reduced healing. However, strong adhesives substantially increase the risk for medical adhesive-associated skin injuries (MARSI) during drape removal/changes. Drape removal can cause epidermal layers to separate and/or detach from the dermis, resulting in skin tears and moisture-associated skin damage, and skin irritation. Studies show the type of drape used correlates with acute pain during dressing changes and injury to the peri-wound tissue, in turn delaying the wound healing process. Previous attempts to develop a product with strong adhesion and easy removability have fallen short. Silicone adhesives have poor skin adherence and are expensive, thus requiring stronger adhering acrylic sealing strips or other acrylic components to mitigate leaks. Addressing this unmet need, Global Biomedical Technologies has developed an adhesive acrylic NPWT drape incorporating innovative ester oligomers that release from the skin with the addition of isopropyl alcohol. This painless adhesive technology, "Comfort Release®," has proven high patient satisfaction with a low incidence of MARSI. This project will confirm the superior functionality and acceptability of Comport Release® NPWT drapes against the market leader (V.A.C. drape by KCI Technologies, Inc.), or standard drape, in both single-use and serial-use NPWT applications. The data obtained from this Direct to Phase II project is expected to support a 510K FDA clearance. The proposed research aims to provide the clinical validation and data needed for a 510 (k) FDA clearance. If successful, the knowledge gained as a result of this trial can bring to market a novel surgical drape for wound therapy that has strong potential to be pain-free and atraumatic and will help facilitate wound healing. This can potentially contribute to improved patient outcomes. Given that there are minimal risks in this trial, we find it reasonable to obtain the knowledge and clinical data needed to bring this drape to pursue FDA clearance and bring this novel NPWT drape to market. Addressing this, Global Biomedical Technologies will compare Comfort Release® NPWT drape with an innovative "switchable adhesive" technology for painless and trauma-free removal with the standard KCI V.A.C.® drape in post-surgical wound patients. The types of post-op wounds that receive NPWT that are eligible for this study include adult acute wounds and incisions, as well as chronic wounds and burns. ________________________________________ Study Design: Single-Center, Two-Armed, Randomized Trial
- Aim 1: Short-duration use (200 patients):
- Assess single-use (in most cases) application, skin irritation, pain at removal, and seal effectiveness.
- Study duration: Approximately 2 years.
- Population: General post-surgical patients.
- Aim 2: Serial-use application (100 patients):
- Assess cumulative effects, including MARSI incidence, narcotic usage, compliance, and leak rates.
- Study duration: Approximately 2 years.
- Population: Chronic wound patients undergoing serial NPWT. Assessments:
- Skin Irritation and Injury:
- Tool: MARSI scoring system (erythema, tension blisters, maceration, etc.).
- Immediate and 30-minute post-removal assessments.
- Pain Evaluation:
- Scale: Indiana Polyclinic Combined Pain Scale (0-10).
- Seal Effectiveness:
- Leak incidence recorded by clinicians.
- Treatment Compliance:
- Monitoring adherence to prescribed NPWT regimens.
- Medication Use:
- Tracking pain and stress-reducing medication usage.
- Clinician Acceptability:
- Documented via case report forms. Risk Mitigation and Ethical Considerations:
- Minimal Risks:
- Potential for skin irritation or discomfort, inherent to NPWT.
- Breach of confidentiality mitigated through deidentification and secure data storage.
- Informed Consent:
- Lay-language consent forms provided, ensuring participants fully understand study procedures, risks, and benefits.
- Oversight by Denise Anderson, RN, WCC, with site coordinators.
- Adverse Event Reporting:
- Immediate reporting of new risks or adverse events to the Columbia IRB. Statistical and Sample Size Justification:
- Aim 1: 200 patients across two sites (CUIMC, AMC). o Effect size: Moderate (d=0.4); significance at α=0.05 with 80% power.
- Aim 2: 25/25/50 patients/group (100 total) at three sites (WCM, VMR, and ASBF). o Effect size: Moderate (d=0.6), targeting higher MARSI incidence in chronic cases. Sponsor \& Principal-Investigator Howard S. Rosing, MD, PhD CEO, Global Biomedical Technologies, LLC 1211 Acorn Knob Greensboro, GA 30642 Contact: hrosing@comfortrelease.com Phone: (m) 239-330-5646 Principal Investigator: Robert John Winchell, MD Chief, Division of Trauma \& Burns Weill Cornell Medical Center (WCM) 525 East 68th Street, Room P7-714, Box 116 New York, NY 10065 Contact: row9057@med.cornell.edu Phone: 646-962-8490 Co-Principal Investigator: Jarrod Terrence Bogue, MD Clinical Instructor in Surgery, Columbia University Irving Medical Center (CUIMC) 161 Fort Washington Avenue, Suite 5 New York, NY 10032 Contact: jb3892@cumc.columbia.edu Phone: 203-668-8595 Co-Principal Investigator: Daniel Careaga, MD- Careaga Plastic Surgery 220 Alhambra Circle, First Floor Coral Gables, FL 33134 Absolute Medical Center (AMC) 5040 Northwest 7th Street Suite 500 Miami, Florida 33126 Contact: Juan Diaz drdiaz@absolutemedicalcenter.com> 305-508-0004 Co-Principal Investigator: Deeza Frankel, DPM Vital Medical Research (VMR) 10780 W Flagler ST, Suite #6 Sweetwater, FL 33174 Contact: Alejandro Morlan, APRN Alejandro.m@vitalmedicalresearch.com 305-703-4414 Co-Principal Investigator: Albert Avi Elhiani, DPM All South Bay Footcare/Podiatry Group, Inc. 23365 Hawthorne Blvd., Suite 101 Torrance, CA 90505 Phone: (310) 326-0202 Second location: Eazy Foot \& Ankle 9233 W. Pico Blvd, #201 Los Angeles, CA 90035 (424) 279-9332 Contact: Rosie Berrios allsouthbayfootcare@gmail.com 310-326-0202 IRB Compliance: Advarra IRB serves as the single IRB for all participating sites. Advarra IRB is fully accredited by the Association for the Accreditation of Human Research Protection Programs (AAHRPP).
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- 50% of the patients will receive the KCI® or standard drape (control), and 50% of the patients will receive the Comfort Release® drape (intervention). Outcomes assessed will include the effectiveness of the seal, pain during dressing removal, skin damage upon removal, and clinician acceptability.
| Arm | Type | Receives |
|---|---|---|
| Single or short-term use post-surgical NPWT drape application | Active comparator | Device: Comfort Release® NPWT drapeAim 1 description: A comparison of the performance of Comfort Release® drapes with V.A.C. drapes in single-use NPWT applications in a randomized controlled trial. Post-surgical patients (n=200) with a prescribed treatment of Negative Pressure Wound Therapy (NPWT) will be enrolled at Columbia Presbyterian Hospital under co-Principal Investigator Dr. Jarrod Bogue and Absolute Medical Center under PI: Daniel Careage, MD, for single-use NPWT. Patients will be randomized to a single-use control (V.A.C. drape) or intervention (Comfort Release® drape). All other components of the NPWT device, including but not limited to the pump, tubing, foam, or dressing insert, will be identical. Randomize participants: 1/2 of the patients will receive the KCI drape, and 1/2 will receive the intervention - Comfort Release drape. |
| Multi-use chronic wound NPWT drape application | Active comparator | Device: Comfort Release® NPWT drapeAim 2: A comparison of the performance of Comfort Release® drapes with V.A.C. drapes in serial-use NPWT applications in a randomized controlled trial. Chronic wound patients (n=100) with prescribed NPWT will be enrolled at Weill Cornell Medical Center under Principal Investigator Dr. Robert Winchell, Vital Medical Research under Deeza Frankel, DPM, and All South Bay Footcare under Albert A. Elhiani, DPM, and Cutting Edge Research under Brock Liden, DPM. All patients will undergo 3 NPWT drape changes per week. Patients will be randomized to control (V.A.C. or standard drape) or intervention (Comfort Release® drape) for the duration of their study enrollment. All other components of the NPWT device, including but not limited to the pump, tubing, foam, or dressing insert, will be identical. Randomize participants: 1/2 of the patients will receive KCI or standard drape, and 1/2 will receive the intervention- Comfort Release drape. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- 18 years or older post-surgical inpatients with a plan of treatment using NPWT
- Able to communicate and consent to participation in the study
- Access to V.A.C. by KCI drape and NPWT kits
- Able to report pain level using a pain scale.
- If outpatient- able to return to the clinic for all drape/dressing changes
Key exclusion criteria (5 listed)
- History of known hypersensitivity to acrylic adhesives
- History of known hypersensitivity to isopropyl alcohol
- The patient is expected to be unconscious during the drape removal/change
- -NOTE: For the Weill Cornell Medicine site only: Patient is expected to be unconscious during ALL drape removal/changes.
- Under the age of 18 years 5. Unable to give consent, including a language barrier, unless an interpreter is readily available.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Comfort Release® NPWT drapeComfort Release® NPWT drape- painless and trauma-free removal, as compared to the control NPWT drape. | Device | Multi-use chronic wound NPWT drape application, Single or short-term use post-surgical NPWT drape application |
Primary outcome
Incidence of Medical Adhesive-Related Skin Injury (MARSI).
Time frame: From the first drape removal to the end of treatment- 1 to 8 weeks.
Measure: The percentage of patients experiencing Medical Adhesive-Related Skin Injury from surgical drape removal as assessed using the MARSI scale upon drape removal, and, if any abnormality is noted, a second MARSI assessment is completed. If there is a MARSI score of 1 or 2 = follow up assessment in completed in approximately 15 minutes, and a score of 3 or 4 = follow up assessment is completed in approximately 30 minutes.
Patient-reported pain scores during drape removal.
Time frame: From enrollment to the end of treatment - from 1 - 8 weeks.
Pain intensity scored on the Indiana Polyclinic Combined Pain Scale during the drape removal. Scale of 0 to10, 0 = no pain and 10= worst imaginable pain.
Change in medication use for anxiety, pain, and stress.
Time frame: From enrollment to the end of treatment - from 1 - 8 weeks.
Measure: Quantity (e.g., dosage or frequency) of medications used for anxiety, pain, and stress related to drape removal.
Drape seal integrity (leak incidence rate).
Time frame: From enrollment to the end of treatment - from 1 - 8 weeks.
Proportion of drapes maintaining an effective seal compared to or the control drape.
Patient drop-out rate from NPWT treatment due to drape issues.
Time frame: From enrollment to the end of treatment - from 1 - 8 weeks.
Measurement: Percentage of patient who discontinue NPWT treatment before completing the prescribed treatment duration drop-out from the prescribed treatment duration to determine how much pain and skin injury plays a role in patient compliance.
1 secondary outcome
Clinician Acceptability of Comfort Release® drape.
Time frame: From application of the first drape to the end of treatment - from 1 - 8 weeks.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Oct 2026.
- BackgroundThe Indiana Polyclinic Combined Pain Scale. 2022. at https://www.painscale.com/article/the - indiana -polyclinic- combined - pain - scale .)
- Background: PubMed 23759927McNichol L, Lund C, Rosen T, Gray M. Medical adhesives and patient safety: state of the science: consensus statements for the assessment, prevention, and treatment of adhesive-related skin injuries. J Wound Ostomy Continence Nurs. 2013 Jul-Aug;40(4):365-80; quiz E1-2. doi: 10.1097/WON.0b013e3182995516.
- BackgroundNegative Pressure Wound Therapy Market Size, Share & Trends Analysis Report By Product (Conventional NPWT, Single- use NPWT), By Wound Type (Diabetic Foot Ulcers, Venous Leg Ulcers), By End Use, By Region, And Segment Forecasts, 2022 - 2030. 2022. (Accessed July 18, 2022, at https://www.grandviewresearch.com/industry - analysis/negative - pressure - wound - therapy - npwt - market .
- Background: PubMed 32134695Fumarola S, Allaway R, Callaghan R, Collier M, Downie F, Geraghty J, Kiernan S, Spratt F, Bianchi J, Bethell E, Downe A, Griffin J, Hughes M, King B, LeBlanc K, Savine L, Stubbs N, Voegeli D. Overlooked and underestimated: medical adhesive-related skin injuries. J Wound Care. 2020 Mar 1;29(Sup3c):S1-S24. doi: 10.12968/jowc.2020.29.Sup3c.S1. No abstract available.
- Background: PubMed 19903300Sen CK, Gordillo GM, Roy S, Kirsner R, Lambert L, Hunt TK, Gottrup F, Gurtner GC, Longaker MT. Human skin wounds: a major and snowballing threat to public health and the economy. Wound Repair Regen. 2009 Nov-Dec;17(6):763-71. doi: 10.1111/j.1524-475X.2009.00543.x.
- BackgroundNational Health Statistic Report, Number 102, February 28, 2017
- Background: PubMed 28345371Apelqvist J, Willy C, Fagerdahl AM, Fraccalvieri M, Malmsjo M, Piaggesi A, Probst A, Vowden P. EWMA Document: Negative Pressure Wound Therapy. J Wound Care. 2017 Mar 1;26(Sup3):S1-S154. doi: 10.12968/jowc.2017.26.Sup3.S1.
- Background: PubMed 35015413Zaver V, Marietta M, Kankanalu P. Negative Pressure Wound Therapy. 2026 Feb 21. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. Available from http://www.ncbi.nlm.nih.gov/books/NBK576388/
- BackgroundRobertson F, Wang Y, Rosing H. An oligomeric switch that rapidly decreases t he peel strength of a pressure-sensitive adhesive. International Journal of Adhesion and Adhesives 2014; 55:64-8
- Background: PubMed 22584524Upton D, Solowiej K, Hender C, Woodyatt KY. Stress and pain associated with dressing change in patients with chronic wounds. J Wound Care. 2012 Feb;21(2):53-4, 56,58 passim. doi: 10.12968/jowc.2012.21.2.53.
- Background: PubMed 23489350Upton D, Andrews A. Pain and trauma in negative pressure wound therapy: a review. Int Wound J. 2015 Feb;12(1):100-5. doi: 10.1111/iwj.12059. Epub 2013 Mar 12.
- Background: PubMed 17000077Vuerstaek JD, Vainas T, Wuite J, Nelemans P, Neumann MH, Veraart JC. State-of-the-art treatment of chronic leg ulcers: A randomized controlled trial comparing vacuum-assisted closure (V.A.C.) with modern wound dressings. J Vasc Surg. 2006 Nov;44(5):1029-37; discussion 1038. doi: 10.1016/j.jvs.2006.07.030. Epub 2006 Sep 26.
- Comfort Release® website.Link provided by the sponsor.
- Individual participant dataSharing planned: Yes. De-identified study patient data underlying the results reported for the primary and secondary outcome measures, including raw data, comparing the intervention against the market leader control.
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Denise L Anderson, Director of Clinical Operations & Communications, RN, WCC contact
Howard S Rosing, MD, PhD principal investigator
Global Biomedical Technologies, LLC
7 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Comfort Release® NPWT drape in people with Frequency and Type of Medical Adhesive-Related Skin Injury and NPWT Drape Seal Effectiveness Rate (or Leak Incidence Rate), run by Global Biomedical Technologies, LLC at 7 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 21 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 7 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Howard S Rosing, Sponsor, MD, PhD (239-330-5646, hrosing@comfortrelease.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Incidence of Medical Adhesive-Related Skin Injury (MARSI). (time frame: From the first drape removal to the end of treatment- 1 to 8 weeks.). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06717308, which also lists 13 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Oct 2026.