AzTrials
AzTrials

Bone FracturesFAIRNCT06754137

AI-Assisted Fracture Detection in Emergency Radiography

A study testing BoneView AI-Assisted Radiograph Interpretation in people with Bone Fractures, run by Salzburger Landeskliniken at 3 sites in 2 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study evaluates whether artificial intelligence (AI) can support doctors who interpret X-rays for suspected fractures in emergency care. In the participating hospitals, X-rays are usually interpreted first by the frontline treating physician, while the formal radiology report is generally available later and not… Read more about this study

Who is it for?
Ages 2 years and older
Conditions the study is for
Bone Fractures
What is being tested?
BoneView AI-Assisted Radiograph Interpretation
Could I receive a placebo?
No, everyone receives an active treatment
How many people
1,667 participants
Where
3 sitesin 2 countries
Study dates
1 Oct 2025to 30 Apr 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 2 years and older
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Age 2 years or older.
  • Presentation to the emergency department following trauma or relevant joint complaint requiring plain radiographic imaging.
  • Injury involving a single anatomical region within the supported anatomical scope of the AI system.
  • Written informed consent provided by the participant or legally authorized representative, with age-appropriate assent where applicable.

Who cannot join

  • Age younger than 2 years.
  • Injuries involving multiple anatomical regions.
  • Head or cervical spine injuries.
  • Previous radiographic imaging or medical assessment for the same injury before the index presentation.
  • Contraindication to X-ray imaging, including pregnancy.
  • Lack of informed consent.
  • Reduced image quality was not an exclusion criterion. Multiple fractures within the same anatomical injury region were eligible.

Trial locations and contacts

3 sites in 2 countries.

3 sites in 2 countries

Austria2 sites
  • Landesklinik Hallein, Salzburger Landeskliniken

    Hallein, 5400

  • University Hospital Salzburg, Salzburger Landeskliniken

    Salzburg, 5020

Other trials in Austria

Germany1 site
  • University Hosptial Nuremberg, Klinikum Nürnberg

    Nuremberg, 90471

Other trials in Germany

About this study

Official title: Artificial Intelligence-Assisted Fracture Detection in Emergency Radiography: A Multicentre Pragmatic Randomised Controlled Trial

This study evaluates whether artificial intelligence (AI) can support doctors who interpret X-rays for suspected fractures in emergency care.

In the participating hospitals, X-rays are usually interpreted first by the frontline treating physician, while the formal radiology report is generally available later and not before the patient leaves the emergency department. AI may therefore provide an immediate additional assessment while clinical decisions are being made.

Read more

Patients were randomly assigned to one of two groups. In the AI-assisted group, physicians interpreted the X-rays with support from an AI system. In the control group, physicians interpreted the same type of X-rays without AI support. All final diagnoses and treatment decisions remained with the treating physician.

The main question is whether AI assistance affects the time from emergency department triage to discharge. The study also evaluates whether AI influences physician diagnostic confidence, the use of additional imaging, missed fractures, and diagnostic accuracy.

The study included patients aged 2 years or older presenting with an isolated musculoskeletal injury or relevant joint complaint requiring X-ray imaging. No additional imaging or treatment was required solely because of study participation.

Read the detailed description

The FAIR (Fracture detection with AI in emergency Radiography) Trial was a prospective, international, multicentre, pragmatic randomised controlled trial evaluating the clinical impact of artificial intelligence (AI)-assisted interpretation of musculoskeletal radiographs in routine emergency care. The study was conducted across four clinical units at three hospitals in Austria and Germany.

Clinical workflow and randomisation

In the participating departments, radiographs were interpreted by frontline orthopaedic trauma or paediatric physicians, who made immediate diagnostic and treatment decisions. Formal radiology reports were generally available later. The intervention therefore evaluated AI as an additional decision-support tool rather than as a replacement for physician interpretation. Patient encounters were individually randomised using a single sequence generated by the trial statistician. Allocation was concealed using folded, sequentially numbered study forms and revealed after radiography. Patients were then directed to designated AI-assisted or control treatment areas. All clinical decisions remained the responsibility of the treating physician.

AI implementation

The intervention used BoneView version 2.3.8 (Gleamer, Paris, France), which provided visual annotations and classifications for fractures, focal bone lesions, dislocations, and joint effusions. The software version remained unchanged throughout recruitment. At Salzburg and Hallein, BoneView was delivered through Aidoc aiOS version 3.24.0; at Nuremberg, it was integrated through Visage version 7.1.19. Participating physicians received standardised training before using the system. AI output was documented on study case-report forms, although detailed software telemetry on actual viewing behaviour was unavailable.

Protocol evolution

During recruitment, an exploratory unblinded analysis in October 2025 examined prospectively collected clinical and workflow outcomes. Following methodological feedback during the Austrian Science Fund review process in March 2026, the outcome hierarchy for the fracture-focused clinical-effectiveness analysis was revised in consultation with the trial statistician, prioritising time from emergency department triage to discharge over diagnostic accuracy. The amendment did not alter randomisation, clinical procedures, or data collection. The originally registered cost-efficiency outcome was discontinued because the available data did not permit a reliable health-economic evaluation.

Reference standard

For fracture-related diagnostic analyses, a radiologist experienced in musculoskeletal imaging and a senior orthopaedic trauma surgeon reviewed the index radiographs and available clinical information. Disagreements were resolved by consensus or, when necessary, by a third expert. The assessment distinguished fractures visible on the original radiographs from fractures detectable only on subsequent imaging.

Conditions
Bone Fractures
Being tested
BoneView AI-Assisted Radiograph Interpretation
Keywords
Artificial Intelligence, Fracture Detection, Emergency Care, AI-Assisted Diagnosis, Diagnostic Accuracy, Orthopedic Diagnostics, Emergency Radiography, Clinical Decision Support, Diagnostic Confidence, Emergency Department
Medical subject headings
Fractures, Bone, Emergencies

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • BoneView AI-Assisted Radiograph InterpretationDiagnostic test

    BoneView version 2.3.8 (Gleamer, Paris, France) analyzes DICOM radiographs and provides real-time visual annotations and classifications for supported musculoskeletal abnormalities. Physicians in the intervention group could view fracture-related findings as well as other supported outputs, including dislocations, joint effusions, and focal bone lesions.

    At University Hospital Salzburg and Regional Hospital Hallein, BoneView was delivered through the Aidoc aiOS platform (version 3.24.0). At University Hospital Nuremberg, BoneView was integrated directly into the local imaging workflow.

    BoneView was used as a decision-support tool and did not replace physician interpretation or the subsequent formal radiology report.

Study groups in NCT06754137
Study groupRoleWhat they receive
Standard Radiograph Interpretation Without AINo interventionPlain radiographs are interpreted by the frontline treating physician according to routine clinical practice without access to AI output. All diagnostic, imaging, treatment, consultation, and discharge decisions remain the responsibility of the treating physician. Formal radiology reports are generally available later and are not routinely available before completion of the emergency department encounter.
AI-Assisted Radiograph InterpretationExperimentalPlain radiographs are interpreted by the frontline treating physician with access to real-time output from BoneView version 2.3.8 (Gleamer, Paris, France). The AI output is used as diagnostic decision support only; all final diagnostic, imaging, treatment, consultation, and discharge decisions remain the responsibility of the treating physician.
Receives: Diagnostic Test: BoneView AI-Assisted Radiograph Interpretation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time from Emergency Department Triage to Discharge

    Time in minutes from formal emergency department triage to discharge during the index encounter, compared between the AI-assisted and control groups.

    Measured: During the index emergency department encounter (day 1).

Secondary outcomes (4)
  1. Missed fractures

    Proportion of patient encounters with a fracture visible on the index radiographs, according to the expert-adjudicated reference standard, in which the fracture was not identified by the frontline treating physician during the initial diagnostic assessment. The reference standard is established by a radiologist and a senior orthopaedic trauma surgeon, with disagreements resolved by consensus or a third expert. Fractures identified on subsequent imaging but not visible on the original radiographs are not classified as missed radiographically visible fractures.

    Measured: At the initial diagnostic assessment during the index emergency department encounter (day 1), with subsequent expert reference-standard adjudication.

  2. Additional Diagnostic Imaging Requested

    Proportion of patient encounters in which the treating physician requested additional diagnostic imaging during the index emergency department visit. The frequency of additional imaging requests is compared between the AI-assisted and control groups.

    Measured: During the index emergency department encounter (day 1), following initial radiographic assessment.

  3. Physician Diagnostic Confidence

    The level of confidence reported by physicians in their diagnostic decisions, measured on a Likert scale (1-10). This will compare how confident physicians feel when using AI assistance versus relying solely on their expertise.

    Measured: Measured immediately after the diagnosis

  4. Diagnostic Accuracy of Fracture/Dislocation/Effusion/Bone Lesion Detection

    The primary outcome measures the diagnostic accuracy of detecting broken bones/dislocations/effusions/bone lesions using sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC). Diagnostic accuracy will be compared between the AI-assisted diagnostic approach and the standard physician-only approach. The gold standard for comparison will be determined by expert consensus based on independent review by a radiologist and an orthopedic specialist.

    Measured: At the time of initial diagnosis, within 2 hours of patient presentation to the orthopedic emergency unit

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted31 Dec 2024
  2. Study start1 Oct 2025
  3. Primary completion30 Apr 2026
  4. Study completion30 Apr 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Model description
Participants were individually randomized in a 1:1 ratio to AI-assisted radiograph interpretation or standard radiograph interpretation without AI assistance. A single global randomization sequence was generated by the trial statistician and used across all three participating centers.
Masking
None (open label)
Enrolment
1,667 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06754137
Sponsor's protocol ID
KI-FRACTURE_001_2024-11-27
Acronym
FAIR
Status last verified
Oct 2026
First submitted
9 Dec 2024
Last updated
6 Nov 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: De-identified individual participant data underlying the results reported in the primary publication will be made available to qualified researchers upon reasonable written request. Shared data may include participant demographics, anatomical injury region, frontline physician diagnosis, AI findings, expert-adjudicated reference-standard findings, diagnostic confidence, additional imaging, and timing data used to derive the primary endpoint. Data will be shared only for scientifically justified research purposes following review and approval of the proposed project by the study investigators and execution of an appropriate data-sharing agreement. Data sharing will comply with applicable institutional requirements, the General Data Protection Regulation (GDPR), and relevant Austrian and German data-protection legislation.

Publications

  • Breitwieser M, Zirknitzer S, Poslusny K, Freude T, Scholsching J, Bodenschatz K, Wagner A, Hergan K, Schaffert M, Metzger R, Marko P. AI in Fracture Detection: A Cross-Disciplinary Analysis of Physician Acceptance Using the UTAUT Model. Diagnostics (Basel). 2025 Aug 21;15(16):2117. doi: 10.3390/diagnostics15162117.

    PubMed 40870969

Questions about this trial

What is this clinical trial studying?

A study testing BoneView AI-Assisted Radiograph Interpretation in people with Bone Fractures, run by Salzburger Landeskliniken at 3 sites in 2 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 6 Nov 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Austria, Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time from Emergency Department Triage to Discharge (time frame: During the index emergency department encounter (day 1).). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06754137, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in