Ventricular DysfunctionNCT06817044
Optimising Screening for the Cardiotoxic Effects of Cancer Therapy
An observational study of Ventricular Dysfunction and Cardiotoxicity, run by Barts & The London NHS Trust at 1 site in United Kingdom.
Trial summary
Cancer is a major worldwide health problem, with around 330.000 new annual cases only in the UK. Improved survival rates due to better treatments have lead to an increase in the prevalence of chemotherapy related cardiac disease (particularly with the use of anthracyclines and Trastuzumab). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Ventricular Dysfunction, Cardiotoxicity, Chemotherapeutic Toxicity
- How many people
- 80 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- Nov 2016to Sep 2018
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Cancer patients who have/ will received cardiotoxic chemotherapy
Who may be able to join
- We will include 100 patients, aged 18 or above, who are already booked for cardiac imaging investigations (MUGA scan, echocardiography (TTE) or CMR) to assess their left ventricular systolic function, as part of their routine clinical care. The majority of these patients will be patients who are being screened for cardiac toxicity resulting from cancer therapies. Some patients will be pre-treatment but many will be patients who have started treatment or completed treatment.
Who cannot join
- pregnancy and breast feeding.
- standard contraindications to cardiac MRI including pacemakers/implantable defibrillators, claustrophobia.
- atrial fibrillation
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Direct Comparison of the Accuracy and Reproducibility of MUGA, CMR and Echocardiography for Cardiac Function Assessment in Oncology Patients at Risk of Cardiotoxicity
Cancer is a major worldwide health problem, with around 330.000 new annual cases only in the UK. Improved survival rates due to better treatments have lead to an increase in the prevalence of chemotherapy related cardiac disease (particularly with the use of anthracyclines and Trastuzumab).
Since prognosis and therapeutic decisions are based on the results of these exams, the imaging technique used for sequencial follow up must faithfully reflect changes in cardiac function with the lowest intraobserver, interobserver and intra-study variabilities.
Read more
The key parameter used for screening for myocardial effects of chemotherapy is the ejection fraction, measured either by echocardiography or nuclear techniques (MUGA scans) and/or CMR1. However, there are inherent problems with the sensitivity and reproducibility of ejection fraction as an imaging biomarker2,3 in this context. Advanced echocardiographic methods including myocardial strain and 3D measures offer the promise of potentially greater sensitivity for detecting early cardiac dysfunction4, however are hindered by a lack of standardisation5.
Conventional CMR is the gold standard method for accuracy and reproducibility for measuring cardiac volumes and ejection fraction6, but is limited in many parts of the world by availability.
To date, there is no head-to-head comparison of both accuracy and reproducibility of all three modalities performed with no temporal gap between them. The investigators will perform a multi-imaging study, where CMR, echocardiography and MUGA departments of Barts Heart Centre will work together to assess which is the best modality for cardiac surveillance in oncology patients.
Whether a technique outperforms others, would clearly improve our cardio-oncology practice.
Read the detailed description
BACKGROUND Cancer is a major worldwide health problem, with around 330 000 new cases diagnosed annually in the UK alone. Improved survival rates due to better treatments have led to an increase in the number of cancer survivors, with over 60% of patients diagnosed expected to survive 5 years. There is also increasing recognition of the cardiotoxic effects of many of the cancer therapies (particularly anthracyclines and Trastuzumab), with subclinical cardiotoxicity found in 18% of subjects receiving anthracyclines of whom one-third have clinically overt heart failure. With trastuzumab, rates of heart failure are even higher, with more than 15% of subjects having to suspend or discontinue treatment. Early detection of cardiotoxicity however permits treatment and (particularly with trastuzumab) recovery of left ventricular function. Patients should therefore have their cardiac function monitored before, during and after treatment (as per published recommendations) to permit early detection and treatment of resultant cardiotoxicity.
The key parameter used for screening for myocardial effects of chemotherapy is the ejection fraction. Cancer therapeutics related cardiac dysfunction is defined by an asymptomatic reduction >= 10% points of the left ventricular ejection fraction (LVEF) to a value <55% or a reduction of LVEF <= 5% to 55% with symptoms of heart failure7. Conventionally this has been measured by nuclear techniques such as Multiple Gated Acquisition Cardiac Blood Pool imaging (MUGA). More recently, echocardiography or cardiac MRI have also been used to measure ejection fraction, as they are considered to be able to detect cardiac dysfunction at an earlier stage.
Each of the three cardiac imaging modalities has its strengths and limitations:
Transthoracic echocardiography (TTE) is widely used due to its availability, ease of use and absence of radiation. It has the advantage of evaluating not only systolic, but also diastolic and longitudinal function, valve and pericardial disease. However the poor test-retest reproducibility with 2D echocardiography (2DE) reported in previous studies raises concern about the accuracy of the technique, and the risk of erroneously stopping chemotherapy due to changes on LVEF that are only due to measurement noise. Indeed, some studies showed disappointing results, with 11% being the smallest change in EF that can be recognized with 95% confidence. Its limitation of relying on 2D geometrical assumptions in a single plane to estimate ventricular ejection is overcome by three dimensional echocardiography (3DE) which acquires more precise anatomic datasets and has been shown to be more accurate than 2DE for LVEF and volumes.
MUGA, is also a 3D technique that has consistently outperformed 2DE with respect to accuracy, reproducibility, intra and inter-observer variabilities for LVEF measures . It also has the advantage of few technical limitations (obesity, pacemakers and poor windows don´t affect image quality). However, radiation exposure is a common concern. 20-30 mCi of Tc99 exposes patients to 5-10 mSv of radiation, although the linkage of such low levels to increase cancer risk has not been shown.
CMR, the reference standard for cardiac function and volumes, also assesses myocardial mass, pericardium and detects subclinical cardiac disease. However, its high cost, low availability and long exam duration preclude its use for serial follow up. The current general recommendation is to use CMR when considering stopping chemotherapy.
For all three modalities, since therapeutic decisions are based on the results of these serial examinations (with therapies being withheld if deteriorations in cardiac function are detected on serial imaging), the imaging technique used must have optimal test-retest, intraobserver and interobserver reproducibility, with minimal background noise. The optimal imaging modality for screening for cardiotoxicity however remains unknown.
To date, there is no head-to-head comparison of the reproducibility (and accuracy) of all three modalities performed with no temporal gap between them. The investigators will perform a multi-modality imaging study, where the CMR, echocardiography and MUGA departments of Barts Heart Centre will work together to assess which is the best modality for cardiac surveillance in oncology patients. If one technique outperforms the others, implementation of this modality for screening for cardiotoxicity would clearly improve our cardio-oncology practice, and potentially ensure earlier detection of cardiac dysfunction and prevent inappropriate withdrawal of potentially life saving cancer treatments.
Risks and Benefits This study is not primarily designed to benefit the current research participants, however since some of the imaging techniques used can detect subclinical heart disease, in the case of any significant findings being detected, The investigators will inform subjects and offer life-style recommendations and, when necessary, medical treatment. All research data will be anonymised and only the researcher will be able to link data to individual patients.
- TRIAL OBJECTIVES
Main clinical question: Which is the best modality (MUGA, echocardiography or CMR) in terms of test-retest reproducibility for cardiac screening in patients undergoing chemotherapy?
Primary Endpoint: Test-retest reproducibility of MUGA, echocardiogram and CMR.
Secondary Endpoints: Correlation between imaging modalities for assessment of ejection fraction and Intra-observer and inter-observer reproducibility for each of the 3 imaging modalities.
- METHODOLOGY
Inclusion Criteria We will include 100 patients, aged 18 or above, who are already booked for cardiac imaging investigations (MUGA scan, echocardiography (TTE) or CMR) to assess their left ventricular systolic function, as part of their routine clinical care. The majority of these patients will be patients who are being screened for cardiac toxicity resulting from cancer therapies. Some patients will be pre-treatment but many will be patients who have started treatment or completed treatment.
Exclusion Criteria:
- pregnancy and breast feeding.
- standard contraindications to cardiac MRI including pacemakers/implantable defibrillators, claustrophobia.
- atrial fibrillation.
- STUDY PROCEDURES
Patient recruitment Potential participants will be identified from the lists of patients already booked for MUGA scans and TTE at Barts Heart Centre, as part of their standard clinical care.
Study plan The investigators will recruit 100 oncology/ haematology patients who are already scheduled for a MUGA cardiac scan or an echocardiopgraphy at Barts Heart Centre to assess cardiac function, as part of their standard clinical investigations.
Patients will be invited to participate in the study, which would require them to also undergo cardiac assessment with other imaging modality on the same day (see diagram below).
Group 1 will undergo their planned MUGA plus a repeat MUGA scan plus 2 CMR scans.
Group 2 will undergo their planned MUGA plus a repeat MUGA scan plus 2 TTE. Group 3 will undergo their planned TTE, plus a repeat TTE plus 2 CMR scans.
No patient will receive more than the standard radiation dose because the repeat MUGA acquired on the same day does not require a second injection of tracer, but simply makes a repeat measurement of activity levels in the heart using the tracer from the initial injection.
Acquired images will be interpreted by two blinded, independent observers. Analysis will be conducted to obtain reliable information on intra-observer, interobserver and test- retest variabilites of each technique.
Imaging Techniques
CMR will be performed using a modified focused protocol in a Siemens 1.5T Avanto scanner. This will take only 10 minutes and includes the localizers, black and white blood sequences and cine images (4 chamber view, 2 chamber view and short axis stack). No contrast agent will be administered.
Analysis will be performed using CVI42 customised software (Circle Cardiovascular) and will be performed by 2 independent, blinded observers with at least SCMR Level 2 accreditation.
2D and 3D Echocardiography will be performed using a GE Vivid9 machine, according to EACVI / BSE protocols. Analysis will be performed using ECHO-PAC software, by two blinded observers with EACVI/BSE accreditation.
MUGA scan will be performed according to the local standard operating procedures (SOP). The patient will be given an injection of stannous medronate reducing agent 20 minutes prior to the injection of 800 MBq of Tc-99m Pertechnetate. Images will be acquired with a dual-head gamma camera (Bright View XCT; Philips healthcare) using a low-energy high-resolution collimator, with energy window of 20% placed over a photopeak of 140 keV.
The LV and RV regions of interest, as well as background activity, will be delineated automatically by the QBS (Quantitative Blood Pool SPECT) software available on the gamma camera processing workstation, with manual correction by the interpreting fellow, if necessary.
Cardiac function measurements LVEF, end-diastolic and end-systolic volumes of the LV (EDV/ESV), global and regional contractility, myocardial mass, as well as early markers of ventricular dysfunction such as longitudinal function, myocardial strain and diastolic parameters (when possible according to the technique).
Acquired images will be anonymized and then interpreted by two blinded, independent observers.
Analysis will be conducted so as to obtain reliable information on test-retest reproducibility for each of the 3 modalities, as well as intraobserver and interobserver variabilites of each technique.
End of Study Definition The study will end after the last patient´s visit and scanning had been performed. At the end of this study, an anonymized summary of the results will be offered to the participants.
REC Reference: 16/LO/1815, IRAS Project ID: 200038
- Medical subject headings
- Ventricular Dysfunction, Cardiotoxicity
What is being measured
The primary outcome is the main question the study is designed to answer.
Ejection fraction measurement reproducibility
Test-retest reproducibility of ejection fraction measurements by echocardiography, nuclear imaging (MUGA) and cardiac MRI
Measured: Single time point
Secondary outcomes (1)
Correlation between imaging modalities for assessment of ejection fraction
Correlation between imaging modalities for assessment of ejection fraction - Bland Altman
Measured: Single time point
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Feb 2025
- Study startNov 2016
- Primary completionFeb 2018
- Study completionSep 2018
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Ventricular DysfunctionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 80 participants (actual)
Sponsor and investigators
- Lead sponsor
- Barts & The London NHS Trust
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06817044
- Sponsor's protocol ID
- 011453
- Status last verified
- Feb 2025
- First submitted
- 20 Jul 2017
- Last updated
- 10 Feb 2025
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Publications
Dowsing B, Menacho K, Culotta V, Meredith B, Unsworth B, Ioannou A, Bhuva A, Davies R, Ferreira A, Ghosh A, Westwood M, Menezes L, Fontana M, Lloyd G, Shun-Shin M, Moon JC, Manisty CH. Fully automated analysis of cardiotoxicity surveillance echocardiograms: a direct test-retest precision comparison with experts. Eur Heart J Imaging Methods Pract. 2026 Aug 21;4(3):qyag142. doi: 10.1093/ehjimp/qyag142. eCollection 2026 Aug.
PubMed 42707651
Study at a glance
From the registry record, last updated by the sponsor on 10 Feb 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Direct Comparison of the Accuracy and Reproducibility of MUGA, CMR and Echocardiography for Cardiac Function Assessment in Oncology Patients at Risk of Cardiotoxicity
- ClinicalTrials.gov ID
- NCT06817044
- Acronym / sponsor ID
- 011453
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 80 participants (actual)
- Lead sponsor
- Barts & The London NHS TrustUniversity, hospital or other
- Study start
- Nov 2016 (actual)
- Primary completion
- Feb 2018 (actual)
- Study completion
- Sep 2018 (actual)
- First posted
- 10 Feb 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Cancer is a major worldwide health problem, with around 330.000 new annual cases only in the UK. Improved survival rates due to better treatments have lead to an increase in the prevalence of chemotherapy related cardiac disease (particularly with the use of anthracyclines and Trastuzumab).
Since prognosis and therapeutic decisions are based on the results of these exams, the imaging technique used for sequencial follow up must faithfully reflect changes in cardiac function with the lowest intraobserver, interobserver and intra-study variabilities.
The key parameter used for screening for myocardial effects of chemotherapy is the ejection fraction, measured either by echocardiography or nuclear techniques (MUGA scans) and/or CMR1. However, there are inherent problems with the sensitivity and reproducibility of ejection fraction as an imaging biomarker2,3 in this context. Advanced echocardiographic methods including myocardial strain and 3D measures offer the promise of potentially greater sensitivity for detecting early cardiac dysfunction4, however are hindered by a lack of standardisation5.
Conventional CMR is the gold standard method for accuracy and reproducibility for measuring cardiac volumes and ejection fraction6, but is limited in many parts of the world by availability.
To date, there is no head-to-head comparison of both accuracy and reproducibility of all three modalities performed with no temporal gap between them. The investigators will perform a multi-imaging study, where CMR, echocardiography and MUGA departments of Barts Heart Centre will work together to assess which is the best modality for cardiac surveillance in oncology patients.
Whether a technique outperforms others, would clearly improve our cardio-oncology practice.
Detailed description
BACKGROUND Cancer is a major worldwide health problem, with around 330 000 new cases diagnosed annually in the UK alone. Improved survival rates due to better treatments have led to an increase in the number of cancer survivors, with over 60% of patients diagnosed expected to survive 5 years. There is also increasing recognition of the cardiotoxic effects of many of the cancer therapies (particularly anthracyclines and Trastuzumab), with subclinical cardiotoxicity found in 18% of subjects receiving anthracyclines of whom one-third have clinically overt heart failure. With trastuzumab, rates of heart failure are even higher, with more than 15% of subjects having to suspend or discontinue treatment. Early detection of cardiotoxicity however permits treatment and (particularly with trastuzumab) recovery of left ventricular function. Patients should therefore have their cardiac function monitored before, during and after treatment (as per published recommendations) to permit early detection and treatment of resultant cardiotoxicity.
The key parameter used for screening for myocardial effects of chemotherapy is the ejection fraction. Cancer therapeutics related cardiac dysfunction is defined by an asymptomatic reduction >= 10% points of the left ventricular ejection fraction (LVEF) to a value <55% or a reduction of LVEF <= 5% to 55% with symptoms of heart failure7. Conventionally this has been measured by nuclear techniques such as Multiple Gated Acquisition Cardiac Blood Pool imaging (MUGA). More recently, echocardiography or cardiac MRI have also been used to measure ejection fraction, as they are considered to be able to detect cardiac dysfunction at an earlier stage.
Each of the three cardiac imaging modalities has its strengths and limitations:
Transthoracic echocardiography (TTE) is widely used due to its availability, ease of use and absence of radiation. It has the advantage of evaluating not only systolic, but also diastolic and longitudinal function, valve and pericardial disease. However the poor test-retest reproducibility with 2D echocardiography (2DE) reported in previous studies raises concern about the accuracy of the technique, and the risk of erroneously stopping chemotherapy due to changes on LVEF that are only due to measurement noise. Indeed, some studies showed disappointing results, with 11% being the smallest change in EF that can be recognized with 95% confidence. Its limitation of relying on 2D geometrical assumptions in a single plane to estimate ventricular ejection is overcome by three dimensional echocardiography (3DE) which acquires more precise anatomic datasets and has been shown to be more accurate than 2DE for LVEF and volumes.
MUGA, is also a 3D technique that has consistently outperformed 2DE with respect to accuracy, reproducibility, intra and inter-observer variabilities for LVEF measures . It also has the advantage of few technical limitations (obesity, pacemakers and poor windows don´t affect image quality). However, radiation exposure is a common concern. 20-30 mCi of Tc99 exposes patients to 5-10 mSv of radiation, although the linkage of such low levels to increase cancer risk has not been shown.
CMR, the reference standard for cardiac function and volumes, also assesses myocardial mass, pericardium and detects subclinical cardiac disease. However, its high cost, low availability and long exam duration preclude its use for serial follow up. The current general recommendation is to use CMR when considering stopping chemotherapy.
For all three modalities, since therapeutic decisions are based on the results of these serial examinations (with therapies being withheld if deteriorations in cardiac function are detected on serial imaging), the imaging technique used must have optimal test-retest, intraobserver and interobserver reproducibility, with minimal background noise. The optimal imaging modality for screening for cardiotoxicity however remains unknown.
To date, there is no head-to-head comparison of the reproducibility (and accuracy) of all three modalities performed with no temporal gap between them. The investigators will perform a multi-modality imaging study, where the CMR, echocardiography and MUGA departments of Barts Heart Centre will work together to assess which is the best modality for cardiac surveillance in oncology patients. If one technique outperforms the others, implementation of this modality for screening for cardiotoxicity would clearly improve our cardio-oncology practice, and potentially ensure earlier detection of cardiac dysfunction and prevent inappropriate withdrawal of potentially life saving cancer treatments.
Risks and Benefits This study is not primarily designed to benefit the current research participants, however since some of the imaging techniques used can detect subclinical heart disease, in the case of any significant findings being detected, The investigators will inform subjects and offer life-style recommendations and, when necessary, medical treatment. All research data will be anonymised and only the researcher will be able to link data to individual patients.
- TRIAL OBJECTIVES
Main clinical question: Which is the best modality (MUGA, echocardiography or CMR) in terms of test-retest reproducibility for cardiac screening in patients undergoing chemotherapy?
Primary Endpoint: Test-retest reproducibility of MUGA, echocardiogram and CMR.
Secondary Endpoints: Correlation between imaging modalities for assessment of ejection fraction and Intra-observer and inter-observer reproducibility for each of the 3 imaging modalities.
- METHODOLOGY
Inclusion Criteria We will include 100 patients, aged 18 or above, who are already booked for cardiac imaging investigations (MUGA scan, echocardiography (TTE) or CMR) to assess their left ventricular systolic function, as part of their routine clinical care. The majority of these patients will be patients who are being screened for cardiac toxicity resulting from cancer therapies. Some patients will be pre-treatment but many will be patients who have started treatment or completed treatment.
Exclusion Criteria:
- pregnancy and breast feeding.
- standard contraindications to cardiac MRI including pacemakers/implantable defibrillators, claustrophobia.
- atrial fibrillation.
- STUDY PROCEDURES
Patient recruitment Potential participants will be identified from the lists of patients already booked for MUGA scans and TTE at Barts Heart Centre, as part of their standard clinical care.
Study plan The investigators will recruit 100 oncology/ haematology patients who are already scheduled for a MUGA cardiac scan or an echocardiopgraphy at Barts Heart Centre to assess cardiac function, as part of their standard clinical investigations.
Patients will be invited to participate in the study, which would require them to also undergo cardiac assessment with other imaging modality on the same day (see diagram below).
Group 1 will undergo their planned MUGA plus a repeat MUGA scan plus 2 CMR scans.
Group 2 will undergo their planned MUGA plus a repeat MUGA scan plus 2 TTE. Group 3 will undergo their planned TTE, plus a repeat TTE plus 2 CMR scans.
No patient will receive more than the standard radiation dose because the repeat MUGA acquired on the same day does not require a second injection of tracer, but simply makes a repeat measurement of activity levels in the heart using the tracer from the initial injection.
Acquired images will be interpreted by two blinded, independent observers. Analysis will be conducted to obtain reliable information on intra-observer, interobserver and test- retest variabilites of each technique.
Imaging Techniques
CMR will be performed using a modified focused protocol in a Siemens 1.5T Avanto scanner. This will take only 10 minutes and includes the localizers, black and white blood sequences and cine images (4 chamber view, 2 chamber view and short axis stack). No contrast agent will be administered.
Analysis will be performed using CVI42 customised software (Circle Cardiovascular) and will be performed by 2 independent, blinded observers with at least SCMR Level 2 accreditation.
2D and 3D Echocardiography will be performed using a GE Vivid9 machine, according to EACVI / BSE protocols. Analysis will be performed using ECHO-PAC software, by two blinded observers with EACVI/BSE accreditation.
MUGA scan will be performed according to the local standard operating procedures (SOP). The patient will be given an injection of stannous medronate reducing agent 20 minutes prior to the injection of 800 MBq of Tc-99m Pertechnetate. Images will be acquired with a dual-head gamma camera (Bright View XCT; Philips healthcare) using a low-energy high-resolution collimator, with energy window of 20% placed over a photopeak of 140 keV.
The LV and RV regions of interest, as well as background activity, will be delineated automatically by the QBS (Quantitative Blood Pool SPECT) software available on the gamma camera processing workstation, with manual correction by the interpreting fellow, if necessary.
Cardiac function measurements LVEF, end-diastolic and end-systolic volumes of the LV (EDV/ESV), global and regional contractility, myocardial mass, as well as early markers of ventricular dysfunction such as longitudinal function, myocardial strain and diastolic parameters (when possible according to the technique).
Acquired images will be anonymized and then interpreted by two blinded, independent observers.
Analysis will be conducted so as to obtain reliable information on test-retest reproducibility for each of the 3 modalities, as well as intraobserver and interobserver variabilites of each technique.
End of Study Definition The study will end after the last patient´s visit and scanning had been performed. At the end of this study, an anonymized summary of the results will be offered to the participants.
REC Reference: 16/LO/1815, IRAS Project ID: 200038
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Cancer patients who have/ will received cardiotoxic chemotherapy
Key inclusion criteria (1 listed)
- We will include 100 patients, aged 18 or above, who are already booked for cardiac imaging investigations (MUGA scan, echocardiography (TTE) or CMR) to assess their left ventricular systolic function, as part of their routine clinical care. The majority of these patients will be patients who are being screened for cardiac toxicity resulting from cancer therapies. Some patients will be pre-treatment but many will be patients who have started treatment or completed treatment.
Key exclusion criteria (3 listed)
- pregnancy and breast feeding.
- standard contraindications to cardiac MRI including pacemakers/implantable defibrillators, claustrophobia.
- atrial fibrillation
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Ejection fraction measurement reproducibility
Time frame: Single time point
Test-retest reproducibility of ejection fraction measurements by echocardiography, nuclear imaging (MUGA) and cardiac MRI
1 secondary outcome
Correlation between imaging modalities for assessment of ejection fraction
Time frame: Single time point
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Feb 2025.
- Derived from this study: PubMed 42707651Dowsing B, Menacho K, Culotta V, Meredith B, Unsworth B, Ioannou A, Bhuva A, Davies R, Ferreira A, Ghosh A, Westwood M, Menezes L, Fontana M, Lloyd G, Shun-Shin M, Moon JC, Manisty CH. Fully automated analysis of cardiotoxicity surveillance echocardiograms: a direct test-retest precision comparison with experts. Eur Heart J Imaging Methods Pract. 2026 Aug 21;4(3):qyag142. doi: 10.1093/ehjimp/qyag142. eCollection 2026 Aug.
Related trials for Ventricular Dysfunction
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
RecruitingObservational study
Natural History Study of Biomarkers in Pulmonary Arterial Hypertension
Pulmonary Disease, Pulmonary Hypertension
Active, not recruiting
Investigation of the BrioVAD System for the Treatment of Left Ventricular Heart Failure
Cardiovascular Diseases, Heart Diseases
RecruitingObservational study
dPmax for Predicting Right Ventricular Failure After Left Ventricular Assist Device Implantation
Ventricular Dysfunction, Right
RecruitingObservational study
Right Ventricular Function and Respiratory Acidosis After Cardiac Surgery
Respiratory Acidosis in ICU Patients, Right Ventricular (RV) Dysfunction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Ventricular Dysfunction and Cardiotoxicity, run by Barts & The London NHS Trust at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 10 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Ejection fraction measurement reproducibility (time frame: Single time point). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06817044, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Feb 2025.