AzTrials
AzTrials

Laparoscopic SurgeryNCT06838078

Trend Correlation Between End-Tidal and Arterial Carbon Dioxide During Laparoscopic Surgery in Trendelenburg Position

An observational study of Laparoscopic Surgery and Trendelenburg Position, run by Koç University.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

In this study, we want to find out whether a person's "end-tidal carbon dioxide" (ETCO₂)-a value measured from the air they breathe out-accurately reflects the amount of carbon dioxide in their blood, called "arterial carbon dioxide" (PaCO₂). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Laparoscopic Surgery, Trendelenburg Position
How many people
79 participants
Where
No sites listed yet
Study dates
1 Apr 2025to 15 Jun 2025
Phase
Observational

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Participants will be drawn from the adult patient population (≥18 years) scheduled for laparoscopic surgery in the Trendelenburg position at a tertiary care hospital. These individuals are already indicated to receive invasive arterial blood pressure monitoring as part of their routine clinical management. No special outreach or community recruitment methods will be employed; rather, eligible patients will be identified from the hospital's surgical wards and preoperative clinics.

Who may be able to join

  • Scheduled to undergo laparoscopic surgery in the Trendelenburg position
  • Planned to receive invasive arterial blood pressure monitoring as part of routine clinical care (independent of the study)

Who cannot join

  • Chronic obstructive pulmonary disease
  • Pulmonary hypertension
  • Active systemic infection

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Muhammet S Söğüt, Anesthesiologist contact

00905056183219

selmansogut@gmail.com

Kamil Darçın, Anesthesiologist contact

00905055895099

kdarcin@kuh.ku.edu.tr

About this study

Official title: Evaluation of the Trend Correlation Between End-Tidal and Arterial Carbon Dioxide Partial Pressures During Laparoscopic Surgery in the Trendelenburg Position: A Prospective Observational Study

In this study, we want to find out whether a person's "end-tidal carbon dioxide" (ETCO₂)-a value measured from the air they breathe out-accurately reflects the amount of carbon dioxide in their blood, called "arterial carbon dioxide" (PaCO₂).

We are focusing on people having laparoscopic (keyhole) surgery in the Trendelenburg position, which involves tilting the patient's head down to help the surgeon see the surgical area better. This position can sometimes affect carbon dioxide levels in the blood. Right now, doctors must draw blood samples to measure the PaCO₂ level. If we can show that ETCO₂ readings are reliable, doctors may not need to draw blood samples as often.

Read more

During surgery, patients already need a small tube (catheter) in an artery so doctors can closely monitor their blood pressure. Whenever the anesthesiologist decides a blood sample is needed, we will note the blood's PaCO₂ level and compare it with the ETCO₂ reading taken at the same time. We will also record other measurements like heart rate, blood pressure, and temperature.

By comparing these measurements, we hope to learn if the ETCO₂ readings can reliably match the changes in PaCO₂ over time, making it a useful tool to monitor carbon dioxide levels in this type of surgery without needing as many blood tests. We plan to include 79 patients in this study, which should give us enough measurements to see how closely these two methods match.

Read the detailed description

Laparoscopic surgeries performed in the Trendelenburg position require tilting the patient's head downward, which can help provide optimal visualization of the surgical field. However, this position may increase intrathoracic pressure and reduce venous return, leading to potential changes in arterial carbon dioxide (PaCO₂) levels. Arterial blood gas (ABG) sampling remains the gold standard for measuring PaCO₂, but it is invasive, costly, and provides only intermittent data. End-tidal carbon dioxide (ETCO₂) monitoring, available through standard anesthesia devices, offers continuous, noninvasive measurement of exhaled CO₂ and can serve as a surrogate for PaCO₂.

The primary purpose of this study is to evaluate the agreement and trend correlation between ETCO₂ and PaCO₂ in patients undergoing laparoscopic procedures in the Trendelenburg position. If ETCO₂ reliably tracks changes in PaCO₂, clinicians may safely reduce the number of ABG samples required during these operations, minimizing patient discomfort and healthcare costs.

Primary objective: To evaluate the trend correlation between ETCO₂ and PaCO₂ over time using four-quadrant and polar plot analyses.

Secondary objective: To determine the degree of agreement between ETCO₂ and PaCO₂

Study Type: Prospective, observational study. Study Setting: Operating rooms where adult patients (≥18 years old) are scheduled for laparoscopic surgery in the Trendelenburg position and require invasive arterial pressure monitoring as part of their routine care.

Duration: Each patient's participation will be limited to the intraoperative period (i.e., from anesthesia induction to the end of surgery).

Intraoperative management will follow a standardized anesthetic protocol, and ABG samples will be drawn at the anesthesiologist's discretion whenever clinically indicated.

Each time an ABG is taken, the corresponding ETCO₂, PaCO₂, arterial blood pressure, heart rate, and temperature values will be recorded.

Any use of inotropic or antihypertensive infusions will be documented, as such medications can influence hemodynamic stability and possibly ventilatory parameters.

The patient's demographic details (age, sex, height, weight) and the type of surgical procedure will be recorded.

Four-quadrant and polar plots will be generated to assess the concordance of changes in ETCO₂ with changes in PaCO₂ over time.

Bland-Altman plots will be constructed to calculate the mean difference (bias) and 95% limits of agreement for each paired measurement.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Trend correlation between ETCO₂ and PaCO₂ measured by the concordance ratio in the four-quadrant plot

    A four-quadrant plot will be generated by comparing consecutive changes (deltas) in PaCO₂ and ETCO₂. For each patient, every pair of sequential measurements will be used to calculate ΔPaCO₂ (horizontal axis) and ΔETCO₂ (vertical axis). Points in the top-right (Quadrant I) and bottom-left (Quadrant III) indicate concordant changes (both variables increased or both decreased). A "central zone" will be defined to exclude clinically negligible fluctuations (±1mmHg). The percentage of points in Quadrant I and III, relative to those outside the central zone, will be reported as the overall concordance. A concordance ratio above 90% will be considered as good trending ability.

    Measured: During the surgery of the patient, arterial blood gas samples will be drawn at the anesthesiologist's discretion whenever clinically indicated.

  2. Trend correlation between ETCO₂ and PaCO₂ measured by the angular bias in the four-quadrant plot

    In the four-quadrant plot, the angle of each data point relative to the 45-degree line will be calculated. The average of this angles will be reported as angular bias. An angular bias between ±5 degrees will be considered as good trending ability.

    Measured: During the surgery of the patient, arterial blood gas samples will be drawn at the anesthesiologist's discretion whenever clinically indicated.

  3. Trend correlation between ETCO₂ and PaCO₂ measured by radial limits of aggreement in the four-quadrant plot

    In the four-quadrant plot, the angle of each data point relative to the 45-degree line will be calculated. The radial sector that contains 95% of the data points will be reported as radial limits of agreement. Radial limits of agreement between ±30 degrees will be considered as good trending ability.

    Measured: During the surgery of the patient, arterial blood gas samples will be drawn at the anesthesiologist's discretion whenever clinically indicated.

Secondary outcomes (1)
  1. Aggreement between simultaneous ETCO₂ and PaCO₂ values measured by limits of aggreement in Bland-Altman plot

    A Bland-Altman plot will be used to assess agreement between ETCO₂ and PaCO₂. For each paired measurement, the difference between ETCO₂ and PaCO₂, and the average of ETCO₂ and PaCO₂ will be calculated. Each point will be plotted with the difference on the vertical axis against the average on the horizontal axis. The mean difference (bias) and 95% limits of agreement (mean difference ± 1.96 × SD of the difference) will then be calculated. Limits of aggreement between ±4 mmHg will be considered as good aggreement.

    Measured: During the surgery of the patient, arterial blood gas samples will be drawn at the anesthesiologist's discretion whenever clinically indicated.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted20 Feb 2025
  2. Study start1 Apr 2025 (estimated)
  3. Primary completion1 Jun 2025 (estimated)
  4. Study completion15 Jun 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
79 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06838078
Sponsor's protocol ID
2024.271.IRB1.035
Status last verified
Feb 2025
First submitted
12 Feb 2025
Last updated
20 Feb 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in