Childbirth is an intense physical and psychological experience. Epidural analgesia (EP) remains the gold standard in labor pain management. However, continuous refinements are aimed at enhancing analgesic quality and mitigating adverse effects. Read more about this study

Who is it for?
Ages 18 to 40 years, women only
Conditions the study is for
Labor Pain, Epidural Analgesia
What is being tested?
Standard Epidural Analgesia and Dural Puncture Epidural Analgesia
Type of treatment
Surgery or procedure
How many people
100 participants
Where
1 siteTurkey (Türkiye)
Study dates
10 Mar 2025to 20 Dec 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 40 years
  • Women only
  • No healthy volunteers
  • Adult

Study population: The study population consists of healthy pregnant women (ASA physical status I-II) with a singleton pregnancy at 37-42 weeks of gestation, who planned a vaginal delivery and requested labor analgesia during active labor (cervical dilation ≥ 4 cm) at a single university hospital.

Who may be able to join

  • American Society of Anesthesiologists (ASA) physical status I-II
  • Gestational age 37-42 weeks
  • Planned vaginal delivery
  • Request for labor analgesia during active labor with cervical dilation ≥ 4 cm

Who cannot join

  • Multiple gestations
  • Diagnosis of preeclampsia/eclampsia
  • Severe systemic disease
  • Contraindications to epidural analgesia (e.g., coagulopathy, infection at the injection site)
  • History of opioid dependence
  • Refusal to participate in the study protocol
  • Missing data in medical records for the retrospective group

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Medipol University

    Istanbul

Other trials in Turkey (Türkiye)

About this study

Official title: Comparison of Standard Epidural and Dural Puncture Epidural Techniques in Labor Analgesia

Childbirth is an intense physical and psychological experience. Epidural analgesia (EP) remains the gold standard in labor pain management. However, continuous refinements are aimed at enhancing analgesic quality and mitigating adverse effects. In recent years, the dural puncture epidural (DPE) technique has gained popularity. In this technique, the dura is intentionally punctured with a spinal needle before the epidural catheter is placed, but no intrathecal medication is administered. This historically controlled study evaluates the clinical outcomes of a protocol transition from standard high-dose epidural to low-dose DPE. The primary objective is to compare total analgesic consumption and success rates of labor analgesia between the two techniques. The secondary objectives include the assessment of hemodynamic parameters, motor block characteristics, adverse effects (such as paresthesia and hypotension), and overall maternal satisfaction

Read the detailed description

The maternal pain experience encompasses psychological and emotional components, highlighting the necessity for patient-centered assessment approaches. While standard epidural and combined spinal-epidural (CSE) techniques are common, they carry risks such as inadequate sacral coverage, motor block, or fetal bradycardia. The dural puncture epidural (DPE) technique aims to combine the advantages of EP and CSE while minimizing their disadvantages. By creating a dural hole, DPE facilitates the translocation of epidural medications into the subarachnoid space, aiming to accelerate the onset of analgesia and improve block quality.This single-center, historically controlled study consists of two consecutive cohorts managed before and after a change in the clinical protocol. Group 1 (retrospective control) received standard concentration epidural analgesia. Group 2 (prospective intervention) received the low-dose DPE technique. The study hypothesizes that the low-dose DPE technique provides non-inferior analgesic efficacy with significantly reduced total bupivacaine consumption and a superior side-effect profile compared to the standard high-dose EP technique. Outcomes evaluated include total bupivacaine consumption, adequate analgesia success (NRS < 4), maternal hemodynamic changes, incidence of adverse effects including paresthesia, and patient satisfaction. Note on outcome reporting: serial intrapartum measurements of maternal blood pressure, maternal heart rate and fetal heart rate were not documented on the routine anesthesia monitoring forms used during the retrospective control period. The registered secondary outcome of maternal hemodynamic and fetal heart rate variation could therefore not be compared between the two cohorts. Baseline values recorded before the procedure were available for all 100 participants and are reported as baseline characteristics, together with the incidence of hypotension and of fetal bradycardia. No registered outcome has been removed from this record.

Being tested
Standard Epidural Analgesia, Dural Puncture Epidural Analgesia
Keywords
Labor Analgesia, Epidural Analgesia, Dural Puncture Epidural
Medical subject headings
Labor Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Standard Epidural AnalgesiaProcedure or surgery

    Administration of conventional epidural analgesia using an 18G Tuohy needle for catheter placement and subsequent administration of a standardized dose of bupivacaine with fentanyl.

  • Dural Puncture Epidural AnalgesiaProcedure or surgery

    Administration of epidural analgesia that incorporates a dural puncture with a 27G spinal needle prior to epidural catheter placement, followed by administration of a lower concentration of bupivacaine with the same dose of fentanyl.

Study groups in NCT06849726
Study groupRoleWhat they receive
Standard Epidural AnalgesiaPatients in this retrospective control group received the standard concentration epidural analgesia. Using an 18-G Tuohy needle, the epidural space was identified and a catheter was advanced. No dural puncture was performed. A loading dose consisting of 0.125% bupivacaine (25 mg) and fentanyl (40 µg) in a total volume of 20 mL was administered via the catheter.
Receives: Procedure: Standard Epidural Analgesia
Dural Puncture Epidural (DPE) AnalgesiaPatients in this prospective intervention group received the low-dose DPE technique. After identifying the epidural space, the dura mater was punctured using a 27-G spinal needle until the clear return of cerebrospinal fluid was visualized. No intrathecal medication was administered, the spinal needle was withdrawn, and the epidural catheter was positioned. A loading dose consisting of 0.0625% bupivacaine (12.5 mg) and fentanyl (40 µg) in a total volume of 20 mL was applied.
Receives: Procedure: Dural Puncture Epidural Analgesia

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Total Analgesic Consumption

    Cumulative bupivacaine consumption measured in milligrams.

    Measured: From the initiation of epidural analgesia until delivery.

  2. Adequate Analgesia Achievement

    Proportion of participants achieving a target Numeric Rating Scale (NRS) score of less than 4

    Measured: Assessed at 15 minutes post-procedure and during hourly follow-ups until delivery.

Secondary outcomes (6)
  1. Incidence of Adverse Effects

    Recording of adverse effects including nausea, vomiting, pruritus, hypotension, and paresthesia

    Measured: Continuously monitored from the initial epidural dose until delivery.

  2. Requirement for Supplemental Analgesia

    Total number of supplemental boluses required during labor

    Measured: From the initiation of epidural analgesia until delivery.

  3. Maternal Satisfaction

    Documented patient satisfaction levels regarding the childbirth experience

    Measured: Assessed in the early postpartum period.

  4. Post-Dural Puncture Headache

    Incidence and severity of post-dural puncture headache in the postpartum period.

    Measured: Up to 1 week postpartum.

  5. Incidence and Severity of Motor Block

    Occurrence and degree of motor block, evaluated by the Modified Bromage Scale.

    Measured: Monitored throughout the procedure until delivery.

  6. Maternal Hemodynamic and Fetal Heart Rate Variations

    Variation in maternal blood pressure, heart rate, and fetal heart rate changes.

    Measured: Continuously monitored throughout the procedure.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Feb 2025
  2. Study start10 Mar 2025
  3. Primary completion20 Oct 2025
  4. Study completion20 Dec 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Other
Enrolment
100 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06849726
Sponsor's protocol ID
Epidural vs DP epidural
Status last verified
Aug 2026
First submitted
18 Feb 2025
Last updated
1 Sep 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: only IPD used in the results publication

Publications

  • Lin W, Yang Y, Lin J, Chen J, Lin Q. Dural Puncture Epidural with 25-G Spinal Needles versus Conventional Epidural Technique in Conjunction with PIEB for Labor Analgesia: A Randomized Trial. J Pain Res. 2023 Nov 8;16:3797-3805. doi: 10.2147/JPR.S424082. eCollection 2023.

    PubMed 38026464
  • Song Y, Du W, Zhou S, Zhou Y, Yu Y, Xu Z, Liu Z. Effect of Dural Puncture Epidural Technique Combined With Programmed Intermittent Epidural Bolus on Labor Analgesia Onset and Maintenance: A Randomized Controlled Trial. Anesth Analg. 2021 Apr 1;132(4):971-978. doi: 10.1213/ANE.0000000000004768.

    PubMed 32282386
  • Wang J, Zhang L, Zheng L, Xiao P, Wang Y, Zhang L, Zhou M. A randomized trial of the dural puncture epidural technique combined with programmed intermittent epidural boluses for labor analgesia. Ann Palliat Med. 2021 Jan;10(1):404-414. doi: 10.21037/apm-20-2281.

    PubMed 33545772

Questions about this trial

What is this clinical trial studying?

An observational study of Labor Pain and Epidural Analgesia, run by Medipol University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Total Analgesic Consumption (time frame: From the initiation of epidural analgesia until delivery.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06849726, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 Sep 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in